| Parameter | Value |
|---|---|
| Item | Specifications |
| Weight | Net weight: 155 g approx., Gross weight: 220 g approx. |
| Details | Aluminum body type |
| Display | 4 digits + 4 digits 2-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) |
| Product | Integrated Display Type Digital Flow Sensor |
| Material | Enclosure: ABS, Body: Polyamide (Aluminum body type: Aluminum), Switch: EPDM, Display: Acrylic, Mounting screw part (Resin body type): Brass Current plate / Port filter: Stainless steel (used for the gas contact area), Sensor chip: Silicon, Gasket: Fluorine rubber |
| Linearity | Within ±3 % F.S. (Ambient temperature +25 ℃ +77 ℉, flow rate range 3 to 100 % F.S., atmospheric criteria on secondary side) |
| Port size | Rc1/2 female thread |
| Protection | IP40 (IEC) |
| Accessories | CN-F15-C1 (Connector attached cable 1 m 3.281 ft): 1 pc. |
| Part Number | FM-216-AR2 |
| Cable length | Total length up to 10 m 32.808 ft is possible with 0.3 mm2, or more, cable. |
| Product name | Integrated Display Type Digital Flow Sensor FM-200 |
| Repeatability | Within ±1 % F.S. |
| External input | ON voltage: 0 to +0.4 VOFF voltage: +5 V to +V, or openInput time: 80 ms or more |
| Product Number | FM-216-AR2 |
| Supply voltage | 12 to 24 V DC ± 10 % Ripple P-P10 % or less |
| Ambient humidity | 35 to 90 % RH, Storage: 35 to 90 % RH |
| Applicable fluid | Clean air, compressed air, nitrogen gas(Note):The clean air complies with JIS B 8392-1.1.1 to 5.6.2, and the compressed air complies with JIS B 8392-1.1.1 to 1.6.2. |
| Shock resistance | 100 m/s2acceleration (10 G approx.) in X, Y and Z directions three times each |
| Connecting method | Connector |
| Comparative output | NPN open-collector transistor・Maximum sink current: 50 mA or less・Applied voltage: 26.4 V DC or less (between comparative output and 0 V)・Residual voltage: 2.4 V or less (at 50 mA sink current) |
| Enclosure earthing | Floating(Note):As a varistor (clamping voltage: approx. 40 V) is connected to the aluminum body type, do not apply voltage higher than the rated voltage of the sensor. |
| Ambient temperature | 0 to +50 ℃ +32 to +122 ℉ (No dew condensation allowed), Storage: -10 to +60 ℃ +14 to +140 ℉ |
| Current consumption | Normal mode: 60 mA or less, ECO mode: 40 mA or less |
| Full scale flow rate | 1,000 ℓ/min.(Note):Converted to volumetric flow at +20 ℃ +68 ℉ and 1 atmospheric pressure (101 kPa). |
| Rated pressure range | -0.09 to +0.7 MPa |
| Vibration resistance | 10 to 150 Hz frequency, 0.75 mm0.030 indouble amplitude or 49 m/s2max. acceleration, in X, Y and Z directions for two hours each |
| Analog voltage output | Output voltage: 1 to 5 V, Output impedance: 1 kΩ approx.[Refer to "Analog voltage output" for more details.] |
| Insulation resistance | 10 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure (Excluding the aluminum body type) |
| Accuracy assurance range | Bi-direction : -100 to -3 % F.S., +3 to +100 % F.S.One-side direction : +3 to +100 % F.S.(Note):Take care that if fluid flows in the vicinity of zero-point which is out of the accuracy assurance range, the instant flow rate value may forcibly display "zero", or the integrated flow display value may not be counted up, or the integrated pulse output may not be outputted. |
| Pressure characteristics | Within ±5 % F.S. (-0.09 to +0.7 MPa, +25 ℃ +77 ℉, atmospheric criteria on secondary side) |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure (Excluding the aluminum body type) |
| Pressure withstandability | 1 MPa |
| Specified integrated value | 10ℓ |
| Temperature characteristics | Within ±0.2 % F.S./℃ (+25 ℃ +77 ℉ criteria, +15 to +35 ℃ +59 to +95 ℉ ambient temperature range) |
| Comparative output:Hysteresis | Window comparator mode: 1 to 8 % F.S. approx. (variable) (Factory settings: approx. 1 % F.S.), Hysteresis mode: Variable (minimum 1 digit) |
| CE marking directive compliance | EMC Directive, RoHS Directive |
| Comparative output:Output modes | Output OFF mode, window comparator mode, hysteresis mode, integrated output mode, integrated pulse output mode |
| Instant flow rate:Display range | -1,100 to +1,100 ℓ/min.(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.). |
| Comparative output:Response time | 50 ms, 80 ms, 120 ms, 200 ms, 400 ms, 800 ms, 1,500 ms, selectable by key operation |
| Integrated flow rate:Display range | ±9999999 ℓ(Note):The display flow rate range is the case when setting to bi-direction at the flow direction setting. When the flow direction is set to one-side forward direction or one-side reverse direction, the negative side of the display flow rate range shows 10 % of the full-scale (F.S.). |
| Comparative output:Short-circuit protection | Incorporated |
| Instant flow rate:Setting and display resolution | 1 ℓ/min. |
| Integrated flow rate:Setting and display resolution | 1 ℓ |
Technical specifications and performance data
Installation and operation guide