Key Specifications
:I + II + III
Note:2011
Type:DIN rail module, one-piece
Depth:76.6 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
I + II + III
Note2011
TypeDIN rail module, one-piece
Depth76.6 mm (incl. DIN rail 7.5 mm)
Width72 mm
Height99.7 mm
EN typeT1 + T2 + T3
Altitude≤ 2000 m (operating voltage remote contact ≤ 250 V)
Product typeCombination type
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Connection nameRemote fault indicator contact
Open side panelNo
Horizontal pitch4 Div.
Housing materialPBT
Pollution degree2
Response time tA≤ 100 ns
Stripping length18 mm
Connection methodScrew connection
Cross section AWG(converted acc. to IEC)
Operating current10 mA AC ... 0.5 A AC
Operating voltage12 V AC ... 250 V AC
Shock (operation)2g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (2,5 mm² ... 16 mm²)
Mode of protectionL-PEN
Nominal voltage UN240/415 V AC (TN-C)
Switching functionChangeover contact
TOV behavior at UT457 V AC (5 s / withstand mode)
Dimensional drawing
Insulating materialPBT
Combination wave UOC6 kV
Degree of protectionIP20 (Installed)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIV (between the main and auxiliary circuit)
Residual current IPE≤ 0.01 mA
CTI value of material600
Rated load current IL80 A (< 55 °C)
Residual voltage Ures≤ 1.7 kV (at In)
Vibration (operation)0,5g (9 … 200 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN-C
IEC test classificationT1 + T2 + T3
Standards/specificationsIEC 61643-11
Conductor cross section AWG13 ... 2
Voltage protection level Up≤ 1.7 kV
Conductor cross section rigid2.5 mm² ... 35 mm²
Maximum continuous voltage UC264 V AC
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 85 °C
Conductor cross section flexible2.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Short-circuit current rating ISCCR25 kA
Follow current interrupt rating Ifi25 kA
Max. backup fuse with branch wiring315 A (gG)
Flammability rating according to UL 94V-0
Nominal discharge current In(8/20) µs25 kA
Ambient temperature (storage/transport)-40 °C ... 85 °C
Max. backup fuse with V-type through wiring80 A (gG)
Total discharge current Itotal(10/350) µs75 kA
Impulse discharge current (10/350) µs, charge12.5 As
Front of wave sparkover voltage at 6 kV (1.2/50) µs≤ 1.7 kV
Impulse discharge current (10/350) µs, peak value limp25 kA
Impulse discharge current (10/350) µs, specific energy156 kJ/Ω

Product Description

High-performance, spark gap-based non-pluggable lightning current arrester / surge protective device for 3-phase power supply networks with common N and PE (4-conductor system: L1, L2, L3, PEN), for l
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified