Service time: Monday to Friday 9:00-18:00
FLT-MB-T1-264/25-1+1-UT - FLT-MB-T1-264/25-1+1-UT 1461299 PHOENIX CONTACT Combined lightning and surge arrester type 1+2+3
In Stock Hot Product

FLT-MB-T1-264/25-1+1-UT

FLT-MB-T1-264/25-1+1-UT 1461299 PHOENIX CONTACT Combined lightning and surge arrester type 1+2+3

$419.77USD
70 in stock
Key Specifications
:I + II + III
Note:2011
Type:DIN rail module, one-piece
Depth:76.6 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
I + II + III
Note2011
TypeDIN rail module, one-piece
Depth76.6 mm (incl. DIN rail 7.5 mm)
Width36 mm
Height89.8 mm
EN typeT1 + T2 + T3
Altitude≤ 5000 m
Product typeCombination type
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Open side panelNo
Horizontal pitch2 Div.
Housing materialPBT
Pollution degree2
Response time tA≤ 100 ns
Stripping length18 mm
Connection methodScrew connection
Cross section AWG(converted acc. to IEC)
Shock (operation)2g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (2,5 mm² ... 16 mm²)
Mode of protectionL-N
Nominal voltage UN240/415 V AC (TN-S)
Dimensional drawing
Insulating materialPBT
Combination wave UOC6 kV
Degree of protectionIP20 (Installed)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIV
Residual current IPE≤ 0.01 mA
CTI value of material600
Rated load current IL80 A (< 55 °C)
Vibration (operation)0,5g (9 … 200 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN-S
IEC test classificationT1 + T2 + T3
TOV behavior at UT(L-N)457 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Residual voltage Ures(L-N)≤ 1.5 kV (at In)
Conductor cross section AWG13 ... 2
Residual voltage Ures(L-PE)≤ 1.7 kV (at In)
Residual voltage Ures(N-PE)≤ 1.3 kV (at In)
Conductor cross section rigid2.5 mm² ... 35 mm²
Maximum continuous voltage UC264 V AC
Surge protection fault messageoptical
Ambient temperature (operation)-40 °C ... 85 °C
Conductor cross section flexible2.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Voltage protection level Up(L-N)≤ 1.5 kV
Voltage protection level Up(L-PE)≤ 2.5 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring315 A (gG)
Flammability rating according to UL 94V-0
Ambient temperature (storage/transport)-40 °C ... 85 °C
Follow current interrupt rating Ifi(N-PE)100 A
Follow current quenching capacity Ifi(L-N)25 kA
Max. backup fuse with V-type through wiring80 A (gG)
Total discharge current Itotal(10/350) µs50 kA
Nominal discharge current In(8/20) µs (L-N)25 kA
Nominal discharge current In(8/20) µs (L-PE)25 kA
Nominal discharge current In(8/20) µs (N-PE)50 kA
Impulse discharge current (10/350) µs (L-PE), charge12.5 As
Impulse discharge current (10/350) µs (N-PE), charge25 As
Impulse discharge current (10/350) µs (L-N), charge12.5 As
Impulse discharge current (10/350) µs (L-N), specific energy156 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), specific energy625 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), specific energy156 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp25 kA
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp50 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp25 kA

Product Description

High-performance, spark gap-based non-pluggable lightning current arrester / surge protective device for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), for light
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top