Key Specifications
:I + II + III
Note:2011
Type:DIN rail module, one-piece
Depth:76.6 mm (incl. DIN rail 7.5 mm)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
I + II + III
Note2011
TypeDIN rail module, one-piece
Depth76.6 mm (incl. DIN rail 7.5 mm)
Width36 mm
Height99.7 mm
EN typeT1 + T2 + T3
Altitude≤ 2000 m (operating voltage remote contact ≤ 250 V)
Product typeCombination type
Screw threadM5
Mounting typeDIN rail: 35 mm
Material groupI
Connection nameRemote fault indicator contact
Open side panelNo
Horizontal pitch2 Div.
Housing materialPBT
Pollution degree2
Response time tA≤ 100 ns
Stripping length18 mm
Connection methodScrew connection
Cross section AWG(converted acc. to IEC)
Operating current10 mA AC ... 0.5 A AC
Operating voltage12 V AC ... 250 V AC
Shock (operation)2g (Half-sine / 11 ms / 3x ±X, ±Y, ±Z)
Tightening torque3 Nm (2,5 mm² ... 16 mm²)
Mode of protectionL-N
Nominal voltage UN240/415 V AC (TN-S)
Switching functionChangeover contact
Dimensional drawing
Insulating materialPBT
Number of positions4
Combination wave UOC6 kV
Degree of protectionIP20 (Installed)
Nominal frequency fN50 Hz (60 Hz)
Overvoltage categoryIV (between the main and auxiliary circuit)
Residual current IPE≤ 0.01 mA
CTI value of material600
Rated load current IL80 A (< 55 °C)
Vibration (operation)0,5g (9 … 200 Hz / 2.5 h / X, Y, Z)
IEC power supply systemTN-S
IEC test classificationT1 + T2 + T3
TOV behavior at UT(L-N)457 V AC (5 s / withstand mode)
Standards/specificationsIEC 61643-11
TOV behavior at UT(N-PE)1200 V AC (200 ms / withstand mode)
Residual voltage Ures(L-N)≤ 1.5 kV (at In)
Conductor cross section AWG13 ... 2
Residual voltage Ures(L-PE)≤ 2.5 kV (at In)
Residual voltage Ures(N-PE)≤ 1.5 kV (at In)
Conductor cross section rigid2.5 mm² ... 35 mm²
Maximum continuous voltage UC264 V AC
Surge protection fault messageOptical, remote indicator contact
Ambient temperature (operation)-40 °C ... 85 °C
Conductor cross section flexible2.5 mm² ... 25 mm²
Permissible humidity (operation)5 % ... 95 %
Voltage protection level Up(L-N)≤ 1.5 kV
Voltage protection level Up(L-PE)≤ 2.5 kV
Voltage protection level Up(N-PE)≤ 1.5 kV
Short-circuit current rating ISCCR25 kA
Max. backup fuse with branch wiring160 A (gG)
Flammability rating according to UL 94V-0
Ambient temperature (storage/transport)-40 °C ... 85 °C
Follow current interrupt rating Ifi(N-PE)100 A
Follow current quenching capacity Ifi(L-N)25 kA
Max. backup fuse with V-type through wiring80 A (gG)
Total discharge current Itotal(10/350) µs25 kA
Nominal discharge current In(8/20) µs (L-N)12.5 kA
Nominal discharge current In(8/20) µs (L-PE)12.5 kA
Nominal discharge current In(8/20) µs (N-PE)25 kA
Impulse discharge current (10/350) µs (L-PE), charge6.25 As
Impulse discharge current (10/350) µs (N-PE), charge12.5 As
Impulse discharge current (10/350) µs (L-N), charge6.25 As
Impulse discharge current (10/350) µs (L-N), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (N-PE), specific energy160 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), specific energy39 kJ/Ω
Impulse discharge current (10/350) µs (L-PE), peak current value Iimp12.5 kA
Impulse discharge current (10/350) µs (N-PE), peak current value Iimp25 kA
Impulse discharge current (10/350) µs (L-N), peak current value Iimp12.5 kA

Product Description

Spark gap-based non-pluggable lightning current arrester / surge protective device free of leakage current for 1-phase power supply networks with separate N and PE (3-conductor system: L1, N, PE), for
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty