

| Parameter | Value |
|---|---|
| GTIN | 4046356135603 |
| Orderkey | 2736848 |
| Catalog page | Page 213 (C-6-2017) |
| Depth (Note) | 50 mm |
| Packing unit | 1 pc |
| Width (Note) | 70 mm |
| Height (Note) | 178 mm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85176200 |
| Designation (General) | Fieldline local bus |
| Designation (Interfaces) | UL |
| Drill hole spacing (Note) | 168 mm |
| Connection method (General) | M12 connector, B-coded |
| Supply voltage (Interfaces) | 24 V DC |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Output name (Digital inputs) | Digital outputs |
| Transmission speed (General) | 500 kbps / 2 Mbps |
| Number of positions (General) | 5 |
| Connection method (Interfaces) | M12 connector |
| Test section (Digital outputs) | To I/O 500 V AC |
| Net weight (Ambient conditions) | 330 g |
| Output voltage (Digital inputs) | 24 V DC |
| Degree of protection (Dimensions) | IP65/IP67 |
| Input name (Fieldline potentials) | Digital inputs |
| Supply voltage range (Interfaces) | 18 V DC ... 30 V DC (including ripple) |
| Connection method (Digital inputs) | M12 connector |
| Filter time (Fieldline potentials) | 3 ms |
| Mounting type (Ambient conditions) | Wall mounting |
| Number of outputs (Digital inputs) | 8 |
| Type of protection (Digital inputs) | Short-circuit protection |
| Input voltage (Fieldline potentials) | 24 V DC |
| Weight per Piece (excluding packing) | 330.000 g |
| Air pressure (operation) (Dimensions) | 80 kPa ... 106 kPa (up to 2000 m above sea level) |
| (Power supply for module electronics) | max. 4 A |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Connection technology (Digital inputs) | 2, 3-wire |
| Designation connection point (General) | Copper cable |
| Number of inputs (Fieldline potentials) | 8 |
| Protection class (Electrical isolation) | III, IEC 61140, EN 61140, VDE 0140-1 |
| Connection method (Fieldline potentials) | M12 connector |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Connection technology (Fieldline potentials) | 2, 3, 4-wire |
| Air pressure (storage/transport) (Dimensions) | 70 kPa ... 106 kPa (up to 3000 m above sea level) |
| Utilization restriction (Key Commercial Data) | 1 |
| Description of the input (Fieldline potentials) | IEC 61131-2 type 1 |
| Maximum output current per channel (Digital inputs) | 500 mA |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Input voltage range "0" signal (Fieldline potentials) | -30 V DC ... 5 V DC |
| Input voltage range "1" signal (Fieldline potentials) | 13 V DC ... 30 V DC |
| Permissible humidity (storage/transport) (Dimensions) | 95 % |
| Connection in acc. with standard (Electrical isolation) | CUL |
| Voltage supply UL (Power supply for module electronics) | 24 V DC |
| Voltage supply US (Power supply for module electronics) | 24 V DC |
| Power supply at UL (Power supply for module electronics) | max. 4 A |
| Power supply at US (Power supply for module electronics) | max. 4 A |
| Voltage supply UA11 (Power supply for module electronics) | 24 V DC |
| Voltage supply UA12 (Power supply for module electronics) | 24 V DC |
| Power supply at UA11 (Power supply for module electronics) | max. 4 A |
| Power supply at UA12 (Power supply for module electronics) | max. 4 A |
| Current consumption at UA11 (Power supply for module electronics) | typ. 3 mA |
| Current consumption at UA12 (Power supply for module electronics) | typ. 3 mA |
| Current consumption from UL (Power supply for module electronics) | max. 55 mA (At 2 Mbaud) |
| Current consumption from US (Power supply for module electronics) | typ. 5 mA (plus power supply for sensors) |
Technical specifications and performance data
Installation and operation guide