

| Parameter | Value |
|---|---|
| -10 °C ... 70 °C (flexible installation) | |
| red | IDC/FLK20 (3) = IDC/FLK14-1 (3) |
| blue | IDC/FLK20 (7) = IDC/FLK14-1 (7) |
| gray | IDC/FLK20 (9) = IDC/FLK14-2 (1) |
| Pitch | 2.54 mm |
| black | IDC/FLK20 (1) = IDC/FLK14-1 (1) |
| brown | IDC/FLK20 (2) = IDC/FLK14-1 (2) |
| green | IDC/FLK20 (6) = IDC/FLK14-1 (6) |
| white | IDC/FLK20 (10) = IDC/FLK14-2 (2) |
| orange | IDC/FLK20 (4) = IDC/FLK14-1 (4) |
| violet | IDC/FLK20 (8) = IDC/FLK14-1 (8) |
| yellow | IDC/FLK20 (5) = IDC/FLK14-1 (5) |
| Altitude | ≤ 2000 m |
| Shielded | no |
| white-red | IDC/FLK20 (13) = IDC/FLK14-2 (5) |
| Cable type | 20X0.14 [PVC] |
| white-blue | IDC/FLK20 (17) = IDC/FLK14-2 (9) |
| white-gray | IDC/FLK20 (19) = IDC/FLK14-1 (9) |
| brown-black | IDC/FLK20 (20) = IDC/FLK14-1 (10) |
| white-black | IDC/FLK20 (11) = IDC/FLK14-2 (3) |
| white-brown | IDC/FLK20 (12) = IDC/FLK14-2 (4) |
| white-green | IDC/FLK20 (16) = IDC/FLK14-2 (8) |
| Cable length | 5 m |
| Halogen-free | no |
| Product type | System cable |
| UL AWM Style | 2464/1061 |
| white-orange | IDC/FLK20 (14) = IDC/FLK14-2 (6) |
| white-violet | IDC/FLK20 (18) = IDC/FLK14-2 (10) |
| white-yellow | IDC/FLK20 (15) = IDC/FLK14-2 (7) |
| Conductor type | Round cable set |
| AWG signal line | 26 |
| Article revision | 03 |
| Cable resistance | ≤ 145 Ω/km (20 °C) |
| Flame resistance | IEC 60332-1-2 (raw cable) |
| Connection method | IDC/FLK socket strip |
| Resistance to oil | can withstand occasional splashes (raw cable) |
| Suitable I/O card | VE4001S2T2B5 |
| Conductor material | Tin-plated Cu litz wires |
| Notes on operation | For proper use, the specifications of the installation directive (see Downloads) must be observed. For applications or use with third-party products, the specifications, and the safety and warning instructions of the respective third-party manufacturer must also be met. |
| Suitable base unit | 6ES7193-6BP00-0BA0 |
| Number of positions | 20 |
| Suitable I/O module | 6ES7131-6BH01-0BA0 (Base Units A0/A1) |
| Degree of protection | IP00 |
| Insulation resistance | ≥ 20 MΩ*km (20 °C) |
| Number of connections | 1 |
| External sheath, color | gray |
| Nominal operating mode | 100% operating factor |
| Operating voltage (AC) | ≤ 30 V AC |
| Operating voltage (DC) | ≤ 60 V DC |
| Outer sheath, material | Semi-rigid PVC |
| Conductor cross section | 20x 0.14 mm² |
| External cable diameter | 7.60 mm ±0.4 mm |
| Current (Per path, 50°C) | ≤ 1 A (Uncoiled, see derating) |
| Current (Per path, 70°C) | ≤ 0.6 A (Uncoiled, see derating) |
| Insertion/withdrawal cycles | > 50 |
| Wire diameter incl. insulation | 1 mm ±0.03 mm |
| Ambient temperature (operation) | -40 °C ... 70 °C (fixed installation) |
| Conductor structure signal line | 7x 0.16 mm |
| Dynamic load capacity (bending) | Max. bending cycles: 5000 (at a radius of ≥ 15x outside diameter) |
| Connection in acc. with standard | based on IEC 60603-13 |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Smallest bending radius, fixed installation | 64 mm |
| Degree of protection (Installation location) | ≥ IP54 (Installation location) |
| Smallest bending radius, movable installation | 120 mm |
Technical specifications and performance data
Installation and operation guide