| Parameter | Value |
|---|---|
| LNK/ACT Link status/data transmission Green LED | |
| ATEX | II 3 G Ex nA nC IIC T4 Gc |
| MTTF | 35.9 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%) |
| Type | Block design |
| Depth | 125 mm |
| IECEx | Ex nA nC IIC T4 Gc |
| Width | 54.4 mm |
| Height | 146.4 mm |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| pluggable | yes |
| CCCex note | Use in potentially explosive areas is not permitted in China. |
| Redundancy | ERR (Extended ring redundancy) |
| Conformance | CE-compliant |
| Product type | Switch |
| Test section | Supply voltage/functional ground 500 V 1 min. |
| Mounting type | DIN rail mounting |
| Inrush current | 4.68 A (3.3 ms) |
| Noise emission | EN 61000-6-4 |
| Noise immunity | EN 61000-6-2:2005 |
| Product family | Managed Switch 3000 |
| Status display | LEDs: US1, US2(redundant voltage supply), link and activity per port |
| Basic functions | Store and forward switch, Extended Ring and IEEE redundancy, Multicast control, IGMP snooping, trunking, Port and Tagging VLANs, Port and IEEE 802.1x security, SNMP V3 and Https security, SNTP, web customization, user accounts |
| Connection name | Power supply |
| No. of channels | 8 (RJ45 ports) |
| Residual ripple | 3.6 VPP(within the permitted voltage range) |
| Article revision | 10 |
| Housing material | Aluminum |
| Protection class | III (VDE 0106, IEC 60536) |
| Stripping length | 7 mm |
| UL, USA / Canada | Class I, Div. 2, Groups A, B, C, D |
| Connection method | RJ45 |
| IECEx certificate | IECEx UL 16.0094X |
| Local diagnostics | US1, US2 Supply voltage Green LED |
| Transmission speed | 10/100 Mbps |
| Dimensional drawing | |
| Note on application | Only for industrial use |
| Supply voltage (DC) | 24 V DC (redundant) |
| Transmission length | 100 m |
| Transmission medium | Copper |
| Degree of protection | IP20 |
| Supply voltage range | 12 V DC ... 48 V DC |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Air pressure (operation) | 57 kPa ... 108 kPa (up to 4850 m above mean sea level) |
| Conductor cross section AWG | 24 ... 12 |
| Typical current consumption | 215 mA (at US= 24 V DC) |
| Note on the connection method | Auto negotiation and autocrossing |
| Conductor cross section, rigid | 0.2 mm² ... 2.5 mm² |
| Signal contact control current | 100 mA |
| Signal contact control voltage | 24 V DC |
| Ambient temperature (operation) | -40 °C ... 75 °C |
| Conformance with EMC directives | IEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion B |
| EU-type examination certificate | DEMKO 16 ATEX 1616X |
| Air pressure (storage/transport) | 57 kPa ... 108 kPa (up to 4850 m above mean sea level) |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Status and diagnostic indicators | LEDs: US1, US2(redundant voltage supply), link and activity per port |
| Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Maximum power dissipation for nominal condition | 5.04 W |
Technical specifications and performance data