| Parameter | Value |
|---|---|
| Aluminum / steel sheet DC01 | |
| MTTF | 75.5 Years (MIL-HDBK-217F standard, temperature 25°C, operating cycle 100%) |
| Depth | 98 mm |
| Width | 22.5 mm |
| Height | 148 mm |
| Altitude | 2000 m (maximum) |
| EMC note | EMC: class A product, see manufacturer's declaration in the download area |
| pluggable | yes |
| Signal LEDs | Data receive, link status |
| Product type | Switch |
| Mounting type | DIN rail mounting |
| Noise emission | EN 61000-6-4:2007 + A1:2011 |
| Noise immunity | EN 61000-6-2:2005 |
| Product family | Unmanaged Switch 1000 |
| Status display | LEDs: US, link and activity per port |
| Basic functions | Unmanaged switch |
| Connection name | Power supply |
| No. of channels | 5 (RJ45 ports) |
| Residual ripple | 3.6 VPP(within the permitted voltage range) |
| Housing material | Polycarbonate fiber reinforced |
| Stripping length | 10 mm |
| UL, USA / Canada | UL 61010-1, UL 61010-2-201, UL 62368-1Class I, Div. 2, Groups A, B, C, D, T4Class I, Zone 2, Group IIC, T4 |
| Connection method | RJ45 |
| MAC address table | 4k |
| Shock (operation) | 30g (EN 60068-2-27) |
| Transmission speed | 10/100/1000 Mbps |
| Supply voltage (AC) | 24 V AC (50/60 Hz) |
| Supply voltage (DC) | 24 V |
| Transmission length | 100 m (per segment) |
| Transmission medium | Copper |
| Additional functions | 100 BASE-TX/100BASE-FX (IEEE 802.3u) |
| Degree of protection | IP30 |
| Number of interfaces | 5 |
| Supply voltage range | 9 V DC ... 32 V DC |
| Transmission physics | Ethernet in RJ45 twisted pair |
| Vibration (operation) | in acc. with IEC 60068-2-6: 5g, 150 Hz |
| Power supply connection | Via COMBICON, max. conductor cross section 2.5 mm² |
| Air pressure (operation) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
| Max. current consumption | 560 mA (at 9 V DC) |
| Conductor cross section AWG | 24 ... 12 |
| Typical current consumption | 33 mA (at 24 V DC) |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Note on the connection method | Auto negotiation and autocrossing |
| Conductor cross section, rigid | 0.2 mm² ... 2.5 mm² |
| Ambient temperature (operation) | -40 °C ... 75 °C |
| Conformance with EMC directives | EN 61000-6-2 EN 61000-4-2 (ESD) Criterion B |
| Air pressure (storage/transport) | 79 kPa ... 108 kPa up to 2000 m above mean sea level (Without derating) |
| Permissible humidity (operation) | 5 % ... 95 % (non-condensing) |
| Status and diagnostic indicators | LEDs: US, link and activity per port |
| Conductor cross section, flexible | 0.2 mm² ... 2.5 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (storage/transport) | 5 % ... 95 % (non-condensing) |
| Conductor cross section, flexible, with ferrule, with plastic sleeve | 0.25 mm² ... 2.5 mm² |
| Conductor cross section flexible, with ferrule without plastic sleeve | 0.25 mm² ... 2.5 mm² |
Technical specifications and performance data
Installation and operation guide