Service time: Monday to Friday 9:00-18:00
FL RED 2001E PRP 2LC - FL RED 2001E PRP 2LC 2701864 PHOENIX CONTACT Redundancy module
In Stock Hot Product

FL RED 2001E PRP 2LC

FL RED 2001E PRP 2LC 2701864 PHOENIX CONTACT Redundancy module

$0.00USD
3139 in stock
Key Specifications
:LNK/ACT Link status/data transmission Green LED
Type:Block design
Depth:109 mm
Width:40 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
LNK/ACT Link status/data transmission Green LED
TypeBlock design
Depth109 mm
Width40 mm
Height100 mm
RedundancyPRP (Parallel Redundancy Protocol)
Product typeSwitch
Mounting typeDIN rail mounting
Noise emissionEN 61000-6-4
Noise immunityIEC 61850-3, IEEE 1613, EN 61000-6-2: 2005
Product familyRedundancy module
Status displayLEDs: US1, US2(redundant voltage supply), link and activity per port
Supply voltage48 V DC (redundant)
Basic functionsEthernet redundancy module for the Parallel Redundancy Protocol
No. of channels1 (RJ45 port)
Residual ripple3.6 VPP(within the permitted voltage range)
Article revision04
Connection methodRJ45
Local diagnosticsUS1, US2 Supply voltage Green LED
Transmission speed10/100 Mbps
Supply voltage (DC)24 V DC (redundant)
Transmission length100 m (per segment)
Transmission mediumMulti-mode fiberglass
Degree of protectionIP20
Supply voltage range18 V DC ... 58 V DC
Transmission physicsCopper
Air pressure (operation)70 kPa ... 106 kPa (3000 m above sea level)
Conductor cross section AWG24 ... 16
Data flow control/protocolsIEC 61850-3, IEEE 1613
Typical current consumption250 mA (at US= 24 V DC)
Electromagnetic compatibilityConformance with EMC Directive 2014/30/EU
Note on the connection methodAuto negotiation and autocrossing
Conductor cross section, rigid0.2 mm² ... 1.5 mm²
Ambient temperature (operation)-40 °C ... 70 °C
Conformance with EMC directivesIEC 61000-6-2 IEC 61000-4-2 (ESD) Criterion A
Air pressure (storage/transport)70 kPa ... 106 kPa (3000 m above sea level)
Permissible humidity (operation)10 % ... 95 % (non-condensing)
Status and diagnostic indicatorsLEDs: US1, US2(redundant voltage supply), link and activity per port
Conductor cross section, flexible0.2 mm² ... 1.5 mm²
Ambient temperature (storage/transport)-45 °C ... 85 °C
Permissible humidity (storage/transport)10 % ... 95 % (non-condensing)
Maximum power dissipation for nominal condition6 W

Product Description

Ethernet redundancy module for redundant networks with the PRP redundancy protocol.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top