| Parameter | Value |
|---|---|
| 2000 m (With UL approval) | |
| ATEX | Ex II 3 G Ex nA IIC T4 Gc X (Please follow the special installation instructions in the documentation!) |
| MTBF | 479 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| MTTF | 1400 Years (SN 29500 standard, temperature 25°C, operating cycle 21 % (5 days a week, 8 hours a day)) |
| Color | green |
| Depth | 114.5 mm |
| Width | 22.5 mm |
| Height | 99 mm |
| Latency | ± 1.3 µs (Store&Forward mode, 10/100 Mbps, depending on the frame size) |
| Altitude | 5000 m (For restrictions see manufacturer's declaration) |
| Net weight | 179 g |
| Wavelength | 1300 nm |
| Conformance | CE-compliant |
| Interface 1 | Ethernet interface, 10/100BASE-T(X) in acc. with IEEE 802.3u |
| Signal LEDs | Activity, link status, 10/100 Mbps |
| Link through | Link fault pass through |
| Basic functions | Store-and-forward media converter |
| Housing material | PA 6.6-FR |
| UL, USA / Canada | cULus listed UL 508 |
| Connection method | Plug-in screw terminal block (COMBICON), redundancy possible |
| Overrange receiver | -14 dBm (dynamic in link mode (average)) |
| Protective circuit | Protection against polarity reversal |
| Transmission length | 100 m (twisted pair, shielded) |
| Transmission medium | Copper |
| Degree of protection | IP20 |
| Electrical isolation | according to IEEE 802.3 |
| Supply voltage range | 18 V DC ... 30 V DC (Screw connection) |
| MDI-/MDI-X switchover | Auto-MDI(X) |
| Standards/regulations | EN 60950-1 |
| Auto-negotiation modes | Auto |
| Transmit capacity, maximum | ≤ -14 dBm ((50/125 µm) dynamic in link mode (average)) |
| Transmit capacity, minimum | ≥ -23.5 dBm ((50/125 µm) dynamic in link mode (average)) |
| Typical current consumption | < 100 mA (24 V DC) |
| Minimum receiver sensitivity | -31 dBm (dynamic in link mode (average)) |
| Electromagnetic compatibility | Conformance with EMC Directive 2004/108/EC (valid until 19.04.2016) / 2014/30/EU (valid from 20.04.2016) |
| Ambient temperature (operation) | -40 °C ... 65 °C |
| Conductor cross section AWG max. | 14 |
| Conductor cross section AWG min. | 24 |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Conductor cross section solid max. | 2.50 mm² |
| Conductor cross section solid min. | 0.20 mm² |
| Conductor cross section flexible max. | 2.50 mm² |
| Conductor cross section flexible min. | 0.20 mm² |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Permissible humidity (storage/transport) | 30 % ... 95 % (non-condensing) |
| Test voltage data interface/power supply | 1.5 kVrms(50 Hz, 1 min.) |
| Max. AWG conductor cross section, flexible | 14 |
| Min. AWG conductor cross section, flexible | 24 |
| Transmission length incl. 3 dB system reserve | 6.4 km (with F-G 50/125 0,7 dB/km F 1000) |
Technical specifications and performance data