| Parameter | Value |
|---|---|
| GTIN | 4046356575072 |
| Orderkey | 2313928 |
| Catalog page | Page 345 (C-6-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| (Serial interface) | EN 61000-4-6 |
| Interface (General) | Ethernet |
| Custom tariff number | 85437090 |
| (Ambient conditions) | 9033 Years (Telcordia standard, 40°C temperature, 34.25% operating cycle (5 days a week, 12 hours a day)) |
| Altitude (Dimensions) | 5000 m (For restrictions see manufacturer's declaration) |
| Interface 1 (General) | Ethernet interface, 10/100Base-T(X) in acc. with IEEE 802.3u |
| Interface 2 (General) | Ethernet interface, 10/100/1000Base-T(X) according to IEEE 802.3u |
| No. of ports (General) | 1 |
| MTBF (Ambient conditions) | 26549 Years (Telcordia standard, 25°C temperature, 21% operating cycle (5 days a week, 8 hours a day)) |
| Signal (Serial interface) | ± 1 kV (Data line, asymmetrical) |
| Color (Ambient conditions) | green |
| Comments (Serial interface) | Criterion B |
| Connection method (General) | COMBICON screw terminal block |
| Depth (Key Commercial Data) | 92 mm |
| Width (Key Commercial Data) | 22.5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 99 mm |
| DNV GL-EMC (Serial interface) | B |
| Transmission length (General) | ≤ 100 m (Total length across both ports (dependent on data rate and cable used)) |
| Test result (Serial interface) | 25g, 11 ms period, half-sine shock pulse |
| Net weight (Ambient conditions) | 90 g |
| Type of test (Serial interface) | Shock in acc. with EN 60068-2-27/IEC 60068-2-27 |
| Degree of protection (Dimensions) | IP20 |
| UL, USA/Canada (Serial interface) | 508 Listed |
| DNV GL-Humidity (Serial interface) | A |
| Frequency range (Serial interface) | 0.15 MHz ... 80 MHz |
| DNV GL-Enclosure (Serial interface) | Required protection according to the Rules shall be provided upon installation on board |
| DNV GL-Vibration (Serial interface) | A |
| Noxious gas test (Serial interface) | ISA-S71.04-1985 G3 Harsh Group A |
| Serial transmission speed (General) | 10/100 Mbps |
| UL, USA/Canada (Ambient conditions) | 508 Listed |
| Contact discharge (Serial interface) | ± 6 kV (Test Level 3) |
| Weight per Piece (excluding packing) | 90.000 g |
| DNV GL-Temperature (Serial interface) | B |
| Housing material (Ambient conditions) | PA 6.6-FR |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Standards/regulations (Serial interface) | EN 50121 and EN 50155 (for railway applications) |
| Electrical isolation (Ambient conditions) | Ethernet // Ethernet |
| Conductor cross section AWG max. (General) | 16 |
| Conductor cross section AWG min. (General) | 26 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 75 °C |
| Conductor cross section solid max. (General) | 1.5 mm² |
| Conductor cross section solid min. (General) | 0.14 mm² |
| Permissible humidity (operation) (Dimensions) | 10 % ... 95 % (non-condensing) |
| Conductor cross section flexible max. (General) | 1.5 mm² |
| Conductor cross section flexible min. (General) | 0.14 mm² |
| Electromagnetic compatibility (Serial interface) | Conformance with EMC Directive 2014/30/EU |
| Electromagnetic compatibility (Ambient conditions) | Conformance with EMC Directive 2014/30/EU |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 85 °C |
| Insulation voltage input/output (Ambient conditions) | 250 Vrms |
| Permissible humidity (storage/transport) (Dimensions) | 5 % ... 95 % (non-condensing) |
| Test voltage data interface/data interface (Ambient conditions) | 4 kV AC (50 Hz, 1 min.) |
Technical specifications and performance data