Service time: Monday to Friday 9:00-18:00
FKC 2,5/ 2-ST-5,08BKBDWH16-18 - FKC 2,5/ 2-ST-5,08BKBDWH16-18 1533575 PHOENIX CONTACT PCB connector, nominal cross-section: 2.5 mm², colour:..
In Stock Hot Product

FKC 2,5/ 2-ST-5,08BKBDWH16-18

FKC 2,5/ 2-ST-5,08BKBDWH16-18 1533575 PHOENIX CONTACT PCB connector, nominal cross-section: 2.5 mm², colour:..

$0.00USD
3101 in stock
Key Specifications
:Cross-section: 0.75 mm²; Length: 8 mm ... 10 mm
Step:5.08 mm
Result:Approved Test
Amplitude:0.35 mm (10 Hz ... 60.1 Hz)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Cross-section: 0.75 mm²; Length: 8 mm ... 10 mm
Step5.08 mm
ResultApproved Test
Amplitude0.35 mm (10 Hz ... 60.1 Hz)
Width [w]10.78 mm
frequency10 - 150 - 10 Hz
Height [h]15 mm
Length [l]25.73 mm
ObservationWEEE/RoHS compliant, filament-free according to IEC 60068-2-82/JEDEC JESD 201
Peel Length10 mm
Plug Cycles25
Sweep speed1 octave/min
Product LineCOMBICON Connectors M
Product TypePrinted Circuit Board Connector
Locking systemwithout
Number of rows1
Product FamilyFKC 2,5/.. -ST
Thermal stress100 °C/168 h
Clamping flangewithout
Color (Housing)Black (9005)
Connection typePush-in spring connection
Nominal Section2.5 mm²
Number of poles2
Connector SystemCOMBICON MSTB 2.5
Contact materialCu Alloy
Dimension Scheme
Number of cycles25
Corrosion fatigue0.2 dm3UNDER2in 300 dm3/40 °C/1 cycle
Type of packagingBoxed Packaging
Contact resistance1 mΩ
Nominal Current IN12 A
Nominal voltage UN320 V
Test SpecificationDIN EN 60999-1 (VDE 0609-1):2000-12
Bearable AC voltage2.21 kV
Degree of pollution3
Insulating materialPA
AWG Conductor Section24 ... 12
Color (Drive Element)Orange (2003)
Contact Resistance R11 mΩ
Contact Resistance R21.1 mΩ
Plug-in force approx.8 N
Nominal voltage (II/2)630 V
Number of poles tested12
Sizing voltage (III/3)320 V
Test duration per axis2.5 h
Contact Connection TypeFemale
Rigid conductor section0.2 mm² ... 2.5 mm²
Surface CharacteristicsMalleable cast iron tinning
Recommended crimp pliers1212034 CRIMPFOX 6
Insulating material groupI
CTI according to IEC 60112600
Flexible conductor section0.2 mm² ... 2.5 mm²
Male gauge a x b / Diameter2.8 mm x 2.0 mm / 2.4 mm
Dimensioning voltage (III/2)320 V
Ambient Temperature (Service)-40 °C ... 100 °C (depending on the rating curve)
Ambient Temperature (Mounting)-5 °C ... 100 °C
Connection Direction Driver/PCB0 °
Nominal transient voltage (II/2)4 kV
Sizing Insulation Voltage (II/2)630 V
Nominal transient voltage (III/2)4 kV
Nominal transient voltage (III/3)4 kV
Sizing Insulation Voltage (III/2)320 V
Sizing Insulation Voltage (III/3)320 V
Minimum creepage line value (II/2)3.2 mm
Bearable shock voltage at sea level4.8 kV
Minimum creepage line value (III/2)3 mm
Minimum creepage line value (III/3)4 mm
Observation regarding the operationAccording to DIN EN 61984, COMBICON connectors are connectors without switching power (COC). In the event of use as prescribed, they must not be plugged in or unplugged under voltage or load.
Insulation Resistance Adjacent Poles> 5 MΩ
Dimensioning transient voltage (II/2)4 kV
Flammability class according to UL 94V0
Power when unplugging by pole approx.6 N
Dimensioning Transient Voltage (III/2)4 kV
Dimensioning transient voltage (III/3)4 kV
Metal surface contact area (top layer)Tin (4 - 8 μm Sn)
Ambient Temperature (Storage/Transport)-40 °C ... 70 °C
Metal surface of the terminal point (top layer)Tin (4 - 8 μm Sn)
Relative humidity of the air (storage/transport)30 % ... 70 %
toe caps with insulated collar, according to DIN 46228-4Cross-section: 0.5 mm²; Length: 8 mm ... 10 mm
Ball hardness test temperature according to EN 60695-10-2125 °C
Resistance to leakage currents (DIN EN 60112 (VDE 0303-11))CTI 600
Flexible conductor section with toe cap, with plastic sleeve0.25 mm² ... 2.5 mm²
toe caps without insulating collar, according to DIN 46228-1Cross-section: 0.5 mm²; Length: 8 mm ... 10 mm
Flexible conductor section with toe cap, without plastic sleeve0.25 mm² ... 2.5 mm²
Minimum Value of Air Insulation Distance - Non-Homogeneous Field (II/2)3 mm
Connection direction of the conductor with respect to the plug direction0 °
Minimum Value of Air Insulation Distance - Non-Homogeneous Field (III/2)3 mm
minimum value of air insulation distance - non-homogeneous field (III/3)3 mm
Conductor Section/Conductor Type/Tensile Force Nominal Value/Actual Value0.2 mm² / rigid / > 10 N
Flammability number of GWFI incandescent filaments according to EN 60695-2-12850
Ignition temperature of incandescent filaments GWIT according to EN 60695-2-13775
2 conductors with the same cross-section, flexible with TWIN toe cap with plastic sleeve0.5 mm² ... 1.5 mm²

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top