| Parameter | Value |
|---|---|
| Plastic body with metal head | |
| Head | Stainless steel 316 |
| Item | Remarks |
| PFHd | 3.44 × 10-8 |
| Type | Housing |
| MTTFd | 356 years |
| Fixing | 2 × M5, 40 mm distance |
| Material | Body |
| M20 Gland | Stainless steel 316 for F3S-TGR-KH16 types |
| Standards | EN1088, IEC 60947-5-1, EN 60204-1, UL508EN ISO 13849-1: up to PLe1EN 62061: up to SIL31 |
| Vibration | IEC 68-2-6, 10-55 Hz +1 Hz, Excursion: 0.35 mm, 1 octave/min |
| Conduit entry | M20 |
| 3NCSlow action | F3S-TGR-KM15-30 |
| for metal head | F39-TGR-KAM |
| heavy flexible | F39-TGR-KHF |
| Mounting screws | Set of Torx safety screws (M4, 4 × 30 mm, 4 × 20 mm, 4 × 10 mm; incl. washers and Torx bit) |
| plastic flexible | F39-TGR-KPF |
| Temperature Range | -25 to 80°C |
| hygienic flexible | F39-TGR-KHFH |
| Horizontal mounting | F39-TGR-KF |
| Enclosure Protection | IP67 |
| Utilization category | AC15 A300 3 A |
| Thermal current (Ith) | 5 A |
| Proof test interval (Life) | 35 years |
| Mechanical reliability B10d | 2.5 × 106operations at 100mA load |
| Actuator entry minimum radius | 175 mm standard, 100mm flexible |
| Body dimensions (W × H × D) | 54 × 88.4 × 34.5 mm |
| Maximum approach/Withdrawal speed | 600 mm/s |
| Rated travel for positive opening | 8 mm |
| Rated insulation/Withstand voltages | 500 VAC/2,500 VAC |
Technical specifications and performance data