| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Output | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Details | Retroreflective type |
| Product | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessory | RF-330 (Reflector): 1 pc.MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysteresis | 20 % or less of operation distance |
| Protection | IP67 (IEC) |
| Part Number | EX-L291-C5 |
| Product name | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repeatability | Perpendicular to sensing axis: 0.2 mm0.0080 inor less |
| Response time | 0.5 ms or less |
| Sensing range | 4 m13.123 ft(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Product Number | EX-L291-C5 |
| Sensing object | Opaque translucent object of ø25 mmø0.984 inor more |
| Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Cable extension | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitting element | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| Shock resistance | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
| Ambient temperature | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Current consumption | 15 mA or less |
| Sensitivity adjuster | Continuously variable adjuster |
| Vibration resistance | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Output operation | Light-ON / Dark-ON selectable by the output operation switching input |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emission spot size (Typical) | Approx. 6 × 4 mm0.236 × 0.157 in(vertical x horizontal)(at a sensing distance of 1 m)(Note) In the case sensing distance is 4 m 13.123 ft, the emission spot size is H 18 x W 10 mmH 0.709 x W 0.394 in(visual reference value). |
| CE marking directive compliance | EMC Directive, RoHS Directive |
| Output:Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimum sensing object (Typical) | - |
| Automatic Interference prevention function | Incorporated(Two sensors can be mounted close together.) |
| Repeatability (Typical)(perpendicular to sensing axis) | - |
Technical specifications and performance data