| Parameter | Value |
|---|---|
| Item | Specifications |
| Cable | 0.15 mm24-core (emitter of a thru-beam type: 2-core) cabtyre cable, 2 m6.562 ftlong |
| Output | NPN open-collector transistor- Maximum sink current: 50 mA- Applied voltage: 26.4 V DC or less (between output and 0 V)- Residual voltage: 2 V or less (at 50 mA sink current), 1 V or less (at 16 mA sink current) |
| Details | Spot reflective type |
| Product | Amplifier Built-in Ultra-compact Laser Sensor |
| Material | Enclosure: Polybutylene terephthalate, Front cover: Acylic, Lens: Glass, Indicator part: Polyarylate |
| Accessory | MS-EXL2-3 (Mounting plate): 1 pc. |
| Hysteresis | 20 % or less of operation distance |
| Protection | IP67 (IEC) |
| Part Number | EX-L221-C5 |
| Product name | Amplifier Built-in Ultra-compact Laser Sensor EX-L200 |
| Repeatability | Perpendicular to sensing axis: 0.05 mm0.0020 inor less |
| Response time | 0.5 ms or less |
| Sensing range | 45 to 300 mm1.772 to 11.811 in(Note)The sensing range is specified for white non-glossy papar (100 x 100 mm3.937 x 3.937 in) as the object. |
| Product Number | EX-L221-C5 |
| Sensing object | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| Supply voltage | 12 to 24 V DC plus or minus 10 % Ripple P-P 10 % or less |
| Cable extension | Extension up to total 50 m164.042 ftis possible with 0.3 mm2, or more, cable. |
| Ambient humidity | 35 to 85 % RH, Storage: 35 to 85 % RH |
| Emitting element | Red semiconductor laser Class 1 (IEC / JIS/ FDA) (Note:This product complies with 21 CFR 1040.10 and 1040.11 Laser Notice No. 50, dated June 24, 2007, issued by CDRH(Center for Devices and Radiological Health) under the FDA (Food and Drug Administration)(Maximum output: 390 μW, Peak emission wavelength: 655 nm0.026 mil) |
| Shock resistance | 500 m/s2acceleration (50 G approx.) in X, Y and Z directions three times each |
| Ambient illuminance | Incandescent light: 3,000 lx or less at the light-receiving face |
| Ambient temperature | -10 to +55 ℃+14 to +131 ℉(No dew condensation or no icing condition),Storage: -30 to +70 ℃-22 to +158 ℉ |
| Current consumption | 15 mA or less |
| Sensitivity adjuster | Continuously variable adjuster |
| Vibration resistance | 10 to 500 Hz frequency, 1.5 mm0.059 indouble amplitude (10 G max.) in X, Y and Z directions for two hours each |
| Insulation resistance | 20 MOhm , or more, with 250 V DC megger between all supply terminals connected together and enclosure |
| Output:Output operation | Light-ON / Dark-ON selectable by the output operation switching input |
| Voltage withstandability | 1,000 V AC for one min. between all supply terminals connected together and enclosure |
| Emission spot size (Typical) | ø1 mmø0.039 inor less(at a sensing distance of 300 mm) |
| CE marking directive compliance | EMC Directive, RoHS Directive |
| Output:Short-circuit protection | Incorporated (short-circuit protection / inverse polarity protection) |
| Minimum sensing object (Typical) | Gold wire of ø0.01 mmø0.0004 in(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
| Automatic Interference prevention function | Incorporated(Two sensors can be mounted close together.) |
| Repeatability (Typical)(perpendicular to sensing axis) | 0.02 mm0.0008 inor less(at 100 to 200 mm sensing distance)(Note)Typical values when the sensitivity adjuster is optimally adjusted. |
Technical specifications and performance data
Installation and operation guide