| Parameter | Value |
|---|---|
| compatible with infrastructure charging plugs | |
| Type | Basic |
| Depth | 87.95 mm |
| Width | 75 mm |
| Design | with round protective cover |
| Height | 91.71 mm |
| Number | 5 (L1, L2, L3, N, PE) |
| Altitude | 5000 m (above sea level) |
| Position | in the frame of the protective cover |
| Cable type | without single-core wires |
| Application | for charging electric vehicles (EV) with alternating current (AC) |
| Affixed logo | PHOENIX CONTACT logo |
| Cable length | 0.5 m |
| Lock setting | LOCK (Lever in horizontal position) |
| Product type | Infrastructure charging socket |
| Charging mode | Mode 3, Case B |
| Fixing screws | M5 thread |
| Rated current | 32 A |
| Rated voltage | 480 V AC |
| Charging power | max. 26.6 kW |
| Product family | CHARX connect modular |
| Cable structure | 3 x 0.5 mm² |
| Color (Housing) | black (9005) |
| Connection type | common cathode |
| Insertion force | < 100 N |
| Cable resistance | ≤ 37.1 Ω/m |
| Charging current | max. 32 A |
| Lock recognition | available |
| Withdrawal force | < 100 N |
| Charging standard | Type 2 |
| Cross section AWG | (converted acc. to IEC) |
| Operating current | < 1.8 A |
| Operating voltage | 12 V |
| Material (Housing) | Plastic |
| Dimensional drawing | |
| Max. wall thickness | max. 50 mm (Rear panel mounting, normative maximum specification for infrastructure plug) |
| Charging power rating | 22 kW |
| Single wire, material | PVC |
| Standards/regulations | IEC 62196-2 |
| Mounting hole diameter | 7.00 mm (ø) |
| Type of cover movement | Self-locking |
| Design (Protective cap) | circular |
| External cable diameter | 1.6 mm ±0.20 mm |
| Color (Protective cover) | black (9005) |
| Note number of positions | 3-pos. |
| Type of charging current | AC 3-phase |
| Design (Protective cover) | circular |
| Material (Contact surface) | Silver |
| Insertion/withdrawal cycles | > 10000 |
| Material (Protective cover) | Plastic |
| Recommended triggering time | 200 ms ... 10 s (ton, typical) |
| Type of signal transmission | Pulse width modulation |
| Mechanical emergency release | available |
| Reverse current of the motor | max. 2.4 A (Stall current) |
| Note on the connection method | Connection via spade connector, separable and reconnectable |
| Service life insertion cycles | > 10000 load cycles |
| Mounting type Protective cover | Rear panel mounting |
| Ambient temperature (operation) | -30 °C ... 50 °C |
| Position of the locking actuator | top center |
| Typical motor current for locking | 250 mA Average run current |
| Pause time after entry or exit path | 8x (ton, typical) |
| Max. dwell time with reverse current | 4 s |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Degree of protection (Protective cover) | IP54 |
| Design (Infrastructure charging socket) | square |
| Possible power supply range at the motor | 9 V ... 15.5 V |
| Screws included in the scope of delivery | none |
| Mounting type Infrastructure charging socket | Rear panel mounting (0 to 90 degree frontal inclination possible) |
| Degree of protection (Infrastructure charging socket) | IP44 (plugged in) |