Service time: Monday to Friday 9:00-18:00
EV-T2M3SE24-3AC20A-0,7M2,5E14 - EV-T2M3SE24-3AC20A-0,7M2,5E14 1627986 PHOENIX CONTACT Socket Outlet
In Stock Hot Product

EV-T2M3SE24-3AC20A-0,7M2,5E14

EV-T2M3SE24-3AC20A-0,7M2,5E14 1627986 PHOENIX CONTACT Socket Outlet

$0.00USD
4943 in stock
Key Specifications
GTIN:4055626370002
Note:Made to Order (non-returnable)
Orderkey:1627986
Catalog page:Page 750 (C-2-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4055626370002
NoteMade to Order (non-returnable)
Orderkey1627986
Catalog pagePage 750 (C-2-2017)
Packing unit1 pc
(Dimensions)IP54 (with protective cover, see accessories)
Country of originDE (Germany)
Material (Design)Plastic
(Locking actuator)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Custom tariff number85444290
(Product definition)0.5 m (Locking actuator cables)
Design line (Mounting)Easy Mount
Service life (Locking)> 10000 load cycles
Locking type (Material)Locking in the inserted state with a locking mechanism
(Mechanical properties)max. 22 mm (Rear panel mounting, normative maximum specification for infrastructure plug when using the protective cover (Order No. 1627635) with fastening frame (Order No. 1627637))
Housing color (Mounting)black
Length of cable (Locking)0.5 m
Depth (Product definition)76.2 mm
Locking voltage (Material)24 V
Max. altitude (Dimensions)5000 m (above sea level)
Type (Key Commercial Data)Front protective cover screw connection
Width (Product definition)75 mm
Height (Product definition)96 mm
Locking detection (Material)available
China RoHS (Locking actuator)Environmentally Friendly Use Period = 10;
Customer variations (Mounting)On request
Degree of protection (Dimensions)IP44 (plugged in)
Product type (Key Commercial Data)Infrastructure Socket Outlet for charging electric vehicles with alternating current (AC), compatible with Infrastructure Plugs
Charging mode (Key Commercial Data)Mode 3, Case B
Bore dimensions (Product definition)60 mm x 60 mm
Cable structure (Product definition)5x 2.5 mm² + 2x 0.5 mm²
Weight per Piece (excluding packing)0.000 g
Conductor length (Product definition)0.7 m (AC cables)
Material surface of contacts (Design)Ag
Number of phases (Ambient conditions)3
Recommended adaptation time (Locking)600 ms
Type of conductor (Product definition)Single wires
Charging standard (Key Commercial Data)Type 2
Insertion force (Electrical properties)< 100 N (Optimized)
Mechanical emergency release (Material)available
Withdrawal force (Electrical properties)< 100 N (Optimized)
Ambient temperature (operation) (Locking)-30 °C ... 50 °C
Max. reverse current of the motor (Locking)0.5 A
Max. wall thickness (Mechanical properties)max. 50 mm (Rear panel mounting, normative maximum specification for infrastructure plug)
Maximum charging power (Ambient conditions)13.8 kW
Standards/regulations (Key Commercial Data)IEC 62196-2
Typical motor current for locking (Locking)0.05 A
Typical power supply at the motor (Locking)24 V
Ambient temperature (operation) (Dimensions)-30 °C ... 50 °C
Number of power contacts (Ambient conditions)5 (L1, L2, L3, N, PE)
Pause time after entry or exit path (Locking)3 s
Type of charging current (Ambient conditions)AC 3-phase
Max. dwell time with reverse current (Locking)1000 ms
Mounting hole diameter (Mechanical properties)7.00 mm (ø)
Number of signal contacts (Ambient conditions)2 (CP, PP)
Maximum voltage for locking detection (Locking)30 V
Type of signal transmission (Ambient conditions)Pulse width modulation
Note on the connection method (Ambient conditions)Crimp connection, cannot be disconnected
Possible power supply range at the motor (Locking)22 V ... 26 V
Insertion/withdrawal cycles (Electrical properties)> 10000
Note on the connection method (Key Commercial Data)Crimp connection, cannot be disconnected
Possible mounting positions (Mechanical properties)Rear panel mounting
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Rated current of power contacts (Ambient conditions)20 A
Rated voltage for power contacts (Ambient conditions)480 V AC
Rated current for signal contacts (Ambient conditions)2 A
Rated voltage for signal contacts (Ambient conditions)30 V AC
Restrictions to mounting position (Mechanical properties)Only 0 to 90 degree frontal inclination possible, see figure
Screw connection of a protective cover (Mechanical properties)only possible on the front
Mounting position of the locking actuator (Mechanical properties)Top center

Product Description

CHARX connect, Infrastructure charging box, front protective cover screw connection, Optimized plug-in and unplug forces, For charging electric vehicles (EV) with alternating current (AC), Compatible
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top