| Parameter | Value |
|---|---|
| GTIN | 4055626379302 |
| Orderkey | 1627785 |
| (Drawings) | |
| Packing unit | 1 |
| (Dimensions) | IP54 (with protective cover, see accessories) |
| Note (Drawings) | Optimized insertion and withdrawal forces |
| Type (Drawings) | Rear protective cover screw connection |
| UNSPSC 11 (ETIM) | 39121522 |
| ETIM 3.0 (eCl@ss) | EC002061 |
| ETIM 4.0 (eCl@ss) | EC002061 |
| ETIM 5.0 (eCl@ss) | EC001321 |
| ETIM 6.0 (eCl@ss) | EC002898 |
| ETIM 7.0 (eCl@ss) | EC002898 |
| Material (Design) | Plastic |
| UNSPSC 13.2 (ETIM) | 39121522 |
| UNSPSC 18.0 (ETIM) | 39121522 |
| UNSPSC 19.0 (ETIM) | 39121522 |
| UNSPSC 20.0 (ETIM) | 39121522 |
| UNSPSC 21.0 (ETIM) | 39121522 |
| UNSPSC 6.01 (ETIM) | 30211923 |
| (Locking actuator) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| UNSPSC 12.01 (ETIM) | 39121522 |
| Custom tariff number | 85444290 |
| UNSPSC 7.0901 (ETIM) | 39121522 |
| (Product definition) | 0.5 m (Locking actuator cables) |
| Design line (Mounting) | Standard |
| Service life (Locking) | > 10000 load cycles |
| Locking type (Material) | Locking in the inserted state with a locking mechanism |
| Product type (Drawings) | Infrastructure Socket Outlet for charging electric vehicles with alternating current (AC), compatible with Infrastructure Plugs |
| (Mechanical properties) | max. 10 mm (Front mounting, when using the locking mechanism) |
| Charging mode (Drawings) | Mode 3, Case B |
| Housing color (Mounting) | black |
| Length of cable (Locking) | 0.5 m |
| Depth (Product definition) | 76.2 mm |
| Locking voltage (Material) | 12 V |
| Max. altitude (Dimensions) | 5000 m (above sea level) |
| Width (Product definition) | 75 mm |
| Height (Product definition) | 96 mm |
| Charging standard (Drawings) | Type 2 |
| Locking detection (Material) | available |
| eCl@ss 4.0 (Classifications) | 27140800 |
| eCl@ss 4.1 (Classifications) | 27140800 |
| eCl@ss 5.0 (Classifications) | 27143400 |
| eCl@ss 5.1 (Classifications) | 27143400 |
| eCl@ss 6.0 (Classifications) | 27143400 |
| eCl@ss 7.0 (Classifications) | 27449001 |
| eCl@ss 8.0 (Classifications) | 27449001 |
| eCl@ss 9.0 (Classifications) | 27144706 |
| China RoHS (Locking actuator) | Environmentally Friendly Use Period = 10; |
| REACh SVHC (Locking actuator) | |
| Customer variations (Mounting) | On request |
| Standards/regulations (Drawings) | IEC 62196-2 |
| Degree of protection (Dimensions) | IP44 (plugged in) |
| Bore dimensions (Product definition) | 60 mm x 60 mm |
| Cable structure (Product definition) | 5x 6.0 mm² + 2x 0.5 mm² |
| Conductor length (Product definition) | 0.7 m (AC cables) |
| Material surface of contacts (Design) | Ag |
| Number of phases (Ambient conditions) | 3 |
| Recommended adaptation time (Locking) | 600 ms |
| Type of conductor (Product definition) | Single wires |
| Insertion force (Electrical properties) | < 100 N (Optimized) |
| Mechanical emergency release (Material) | available |
| Note on the connection method (Drawings) | Crimp connection, cannot be disconnected |
| Withdrawal force (Electrical properties) | < 100 N (Optimized) |
| Ambient temperature (operation) (Locking) | -30 °C ... 50 °C |
| Max. reverse current of the motor (Locking) | 1 A |
| Max. wall thickness (Mechanical properties) | max. 50 mm (Rear panel mounting, normative maximum specification for infrastructure plug) |
| Maximum charging power (Ambient conditions) | 22 kW |
| Typical motor current for locking (Locking) | 0.2 A |
| Typical power supply at the motor (Locking) | 12 V |
| Ambient temperature (operation) (Dimensions) | -30 °C ... 50 °C |
| Number of power contacts (Ambient conditions) | 5 (L1, L2, L3, N, PE) |
| Pause time after entry or exit path (Locking) | 3 s |
| Type of charging current (Ambient conditions) | AC 3-phase |
| Max. dwell time with reverse current (Locking) | 1000 ms |
| Mounting hole diameter (Mechanical properties) | 7.00 mm (ø) |
| Number of signal contacts (Ambient conditions) | 2 (CP, PP) |
| Maximum voltage for locking detection (Locking) | 30 V |
| Type of signal transmission (Ambient conditions) | Pulse width modulation |
| Dimensional drawingDimensional drawing (Drawings) | |
| Note on the connection method (Ambient conditions) | Crimp connection, cannot be disconnected |
| Possible power supply range at the motor (Locking) | 9 V ... 16 V |
| Insertion/withdrawal cycles (Electrical properties) | > 10000 |
| Possible mounting positions (Mechanical properties) | Rear panel mounting |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Rated current of power contacts (Ambient conditions) | 32 A |
| Rated voltage for power contacts (Ambient conditions) | 480 V AC |
| Rated current for signal contacts (Ambient conditions) | 2 A |
| Rated voltage for signal contacts (Ambient conditions) | 30 V AC |
| DiagramLocking states of the locking actuator (Drawings) | |
| Restrictions to mounting position (Mechanical properties) | Only 0 to 90 degree frontal inclination possible, see figure |
| Screw connection of a protective cover (Mechanical properties) | only rear mounting possible |
| Schematic diagramDetection of the Infrastructure Plug (Drawings) | |
| Mounting position of the locking actuator (Mechanical properties) | Top center |
| Connection diagramPin assignment of Infrastructure Socket Outlet (Drawings) | |
| Schematic diagramPanel thickness for rear mounting (max. 50 mm, with Phoenix Contact protective cover, max. 22 mm) (Drawings) | |
| Schematic diagramFront mounting with rear protective cover screw connectionFront mounting is only possible when the locking actuator is removed. We recommend using an infrastructure socket outlet without pre-assembled locking actuator (EV-T2M3SE-...E0..., e.g., 1621729).The screw connection for a protective cover from the accessories range (EV-T2SC) only supports rear mounting. The panel thickness must not exceed 10 mm. The sealing frame that is slid on from the front must contact the housing panel flush with the flat side and must completely surround the infrastructure socket outlet. (Drawings) |
Technical specifications and performance data
Installation and operation guide