| Parameter | Value |
|---|---|
| 0.5 m (Locking actuator cables) | |
| GTIN | 4055626327884 |
| Note | Made to Order (non-returnable) |
| Depth | 76.2 mm |
| Width | 75 mm |
| Height | 96 mm |
| ETIM 3.0 | EC002061 |
| ETIM 4.0 | EC002061 |
| ETIM 5.0 | EC001321 |
| ETIM 6.0 | EC002898 |
| Material | Plastic |
| Orderkey | 1627558 |
| UNSPSC 11 | 39121522 |
| China RoHS | Environmentally Friendly Use Period = 10; |
| eCl@ss 4.0 | 272607xx |
| eCl@ss 4.1 | 27260701 |
| eCl@ss 5.0 | 27260701 |
| eCl@ss 5.1 | 27059110 |
| eCl@ss 6.0 | 27279220 |
| eCl@ss 7.0 | 27061801 |
| eCl@ss 8.0 | 27449001 |
| eCl@ss 9.0 | 27144706 |
| Design line | Standard |
| UNSPSC 13.2 | 39121522 |
| UNSPSC 6.01 | 30211923 |
| Catalog page | Page 756 (C-2-2017) |
| Locking type | Locking in the inserted state with a locking mechanism |
| Packing unit | 1 pc |
| Service life | > 10000 load cycles |
| UNSPSC 12.01 | 39121522 |
| Housing color | black |
| Max. altitude | 5000 m (above sea level) |
| UNSPSC 7.0901 | 39121522 |
| Type of sensor | Pt 1000 |
| Bore dimensions | 60 mm x 60 mm |
| Cable structure | 5x 6.0 mm² + 2x 0.5 mm² |
| Insertion force | < 100 N |
| Length of cable | 0.5 m |
| Locking voltage | 12 V |
| Conductor length | 0.7 m (AC cables) |
| Number of phases | 3 |
| Withdrawal force | < 100 N |
| Country of origin | CN (China) |
| Locking detection | available |
| Temperature range | -50 °C ... 130 °C |
| Type of conductor | Single wires |
| Customer variations | On request |
| Max. wall thickness | > 57 mm (Rear panel mounting) |
| Custom tariff number | 85444290 |
| Degree of protection | IP55 (plugged in) |
| Shutdown temperature | 90 °C equivalent to a Pt 1000 value of 1346.5 Ω |
| Standards/regulations | DIN EN 60751 |
| Maximum charging power | 14 kW |
| Mounting hole diameter | 7.00 mm (ø) |
| Temperature measurement | 4x Pt 1000 (DIN EN 60751) |
| Number of power contacts | 5 (L1, L2, L3, N, PE) |
| Type of charging current | AC 3-phase |
| Number of signal contacts | 2 (CP, CC) |
| Insertion/withdrawal cycles | > 10000 |
| Possible mounting positions | Rear panel mounting |
| Recommended adaptation time | 600 ms |
| Required installation depth | < 5 mm (Rear panel mounting) |
| Type of signal transmission | Pulse width modulation |
| Material surface of contacts | Ag |
| Mechanical emergency release | available |
| Recommended measured current | 1 mA (1 V at 0°C) |
| Temperature coefficient (TCR) | 3850 ppm/K |
| Ambient temperature (operation) | -30 °C ... 50 °C |
| Rated current of power contacts | 32 A |
| Rated voltage for power contacts | 440 V AC |
| Max. reverse current of the motor | 1 A |
| Rated current for signal contacts | 2 A |
| Rated voltage for signal contacts | 30 V AC |
| Restrictions to mounting position | Only 0 to 90 degree frontal inclination possible, see figure |
| Typical motor current for locking | 0.2 A |
| Typical power supply at the motor | 12 V |
| Long-term stability (max. R0-Drift) | 0.06 % (After 1000 hours at 130°C) |
| Pause time after entry or exit path | 3 ms |
| Max. dwell time with reverse current | 1000 ms |
| Weight per Piece (excluding packing) | 580.000 g |
| Maximum voltage for locking detection | 30 V |
| Ambient temperature (storage/transport) | -40 °C ... 80 °C |
| Possible power supply range at the motor | 9 V ... 16 V |
| Mounting position of the locking actuator | Top center |
| Tolerance at the sensor with the recommended measured current | ±1K |
Technical specifications and performance data
Installation and operation guide