| Parameter | Value |
|---|---|
| GTIN | 4055626807652 |
| Note | Made to Order (non-returnable) |
| Orderkey | 1081335 |
| (Mounting) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Packing unit | 1 pc |
| (Switching outputs) | 9.6 kbps ... 19.2 kbps (adjustable) |
| Custom tariff number | 85371098 |
| China RoHS (Mounting) | Environmentally Friendly Use Period = 50 |
| (Key Commercial Data) | SAE J1772 |
| Depth (Product definition) | 67.00 mm |
| Type (Key Commercial Data) | in housing |
| Width (Product definition) | 124 mm |
| Height (Product definition) | 128 mm |
| Bus system (Switching outputs) | RS-485 |
| Max. switching current (Inputs) | 6 A |
| Supply voltage (Connection data) | 230 V |
| Conformance (Key Commercial Data) | CE-compliant |
| Degree of protection (Dimensions) | IP20 |
| Frequency range (Connection data) | 50 Hz ... 60 Hz |
| Mounting position (Device supply) | any |
| Maximum switching voltage (Inputs) | 250 V AC (External supply) |
| Product type (Key Commercial Data) | AC charging controller for private and commercial applications (EU/CN) |
| Charging mode (Key Commercial Data) | Mode 3, Case C |
| Minimum switching capacity (Inputs) | 1500 VA |
| Frequency range (Ambient conditions) | 50 Hz ... 60 Hz |
| Weight per Piece (excluding packing) | 0.000 g |
| Connection method (Switching outputs) | Pluggable spring-cage terminal blocks |
| Control of charging contactor (Inputs) | Relay output C1.2 |
| Supply voltage range (Connection data) | 100 V AC ... 240 V AC (nominal voltage range) |
| Transmission speed (Switching outputs) | 9.6 kbps (Standard) |
| Nominal current IN (Ambient conditions) | ≤ 1 mA |
| Number of interfaces (Switching outputs) | 1 |
| Connection method (RS-485 data interfaces) | Plug-in push-in spring-cage connection |
| Max. current consumption (Connection data) | 40 mA |
| Input voltage range U1 (Ambient conditions) | 0 V ... 3 V (Off) |
| Input voltage range U2 (Ambient conditions) | 9 V ... 15 V (On) |
| Nominal power consumption (Connection data) | < 1 W (No-load) |
| Standards/regulations (Key Commercial Data) | IEC 61851-1 |
| Ambient temperature (operation) (Dimensions) | -35 °C ... 70 °C |
| Nominal input voltage UN (Ambient conditions) | 12 V |
| Number of digital inputs (Ambient conditions) | 5 |
| Permissible humidity (operation) (Dimensions) | 30 % ... 95 % |
| Nominal power consumption (Ambient conditions) | < 0.5 W (No-load) |
| Data flow control/protocols (Switching outputs) | Modbus/RTU (slave) |
| Note on the connection method (Key Commercial Data) | with MSTB connection |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Conductor cross section AWG (RS-485 data interfaces) | 24 ... 16 |
| Conductor cross section solid (RS-485 data interfaces) | 0.2 mm² ... 2.5 mm² |
| Conductor cross section flexible (RS-485 data interfaces) | 0.2 mm² ... 1.5 mm² |
| Number of supported charging points (Key Commercial Data) | 1 |
Technical specifications and performance data