| Parameter | Value |
|---|---|
| Client | |
| Housing | DIN 43880 |
| Altitude | < 2000 m |
| Interface | Ethernet (1x) |
| Bus system | RS-485 |
| Application | AC charging controller for private and commercial applications (EU/CN) |
| Conformance | CE-compliant |
| Output name | 4 digital outputs |
| Product type | AC charging controller |
| Charging mode | Mode 3, Case B + C |
| Mounting type | DIN rail mounting |
| Noise emission | EN 61000-6-3 |
| Noise immunity | EN 61000-6-2 |
| Operating mode | Stand-Alone |
| Product family | CHARX control advanced plus |
| Status display | 5 x LEDs |
| Supply voltage | 230 V |
| Frequency range | 50 Hz ... 60 Hz |
| Article revision | 01 |
| Rated current In | 32 A (Three-phase, 4x6 mm²) |
| Connection method | Connector |
| Mounting position | any |
| Power consumption | < 10 W |
| Nominal current IN | ≤ 4 mA |
| Rated frequency fn | ≤ 2000 Hz |
| Current consumption | < 3 W (No-load) |
| Input voltage range | 0 V ... 3 V (Off) |
| Protocols supported | Modbus/RTU (Master) |
| Transmission length | 100 m |
| Degree of protection | IP20 |
| Number of interfaces | 1 (for energy measurement device and RFID reader) |
| Overvoltage category | II |
| Supply voltage range | 100 V AC ... 240 V AC (nominal voltage range) |
| Connection technology | Screw connection |
| Low Voltage Directive | Conformance with Low Voltage Directive 2014/35/EC |
| Residual current IΔn | 30 mA (AC) |
| Standards/regulations | IEC 61851-1 |
| Input voltage range U2 | 9 V ... 15 V (On) |
| Max. switching current | 16 A |
| Maximum output current | 0.2 A (Total current for all outputs; internally supplied) |
| Maximum output voltage | 30 V |
| Tripping time for IΔn | < 180 ms |
| Description of the input | Digital input |
| Nominal input voltage UN | 12 V |
| Number of digital inputs | 5 |
| Transmission speed range | 4.8 kbps ... 115.2 kbps (adjustable) |
| Tripping time for 5xIΔn | < 20 ms |
| Type of charging current | AC |
| Maximum switching voltage | 250 V AC (External supply) |
| Nominal power consumption | < 3 W (No-load) |
| Number of charging points | 1 |
| Serial transmission speed | 10/100 Mbps |
| Diameter of measuring coil | 15 mm |
| Minimum switching capacity | 4000 VA |
| Response time for 2 x IΔn | < 70 ms |
| Conductor cross section AWG | 24 ... 12 |
| Number of supported devices | 2 |
| Nominal differential current | ± 300 mA |
| Conductor cross section rigid | 0.2 mm² ... 4 mm² |
| Electromagnetic compatibility | Conformance with EMC Directive 2014/30/EU |
| Ambient temperature (operation) | -25 °C ... 60 °C |
| Conductor cross section flexible | 0.2 mm² ... 2.5 mm² |
| Permissible humidity (operation) | 30 % ... 95 % (non-condensing) |
| Immunity to electromagnetic fields | EN 61 000-4-3, 80---1000 MHz, 10 V/m |
| Maximum output current per channel | 0.6 A (Per output; externally supplied) |
| Immunity to fast transients (Burst) | EN 61 000-4-4: 2 kV AC mains input, 1 kV data cable |
| Immunity to conducted high frequency | EN 61 000-4-6, 0.15...80 MHz, 10 V |
| Ambient temperature (storage/transport) | -40 °C ... 85 °C |
| Locking release in the event of mains failure | Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet |
| Immunity to the discharge of static electricity | EN 61000-4-2: 8 kV air, 4 kV contact discharge |
Technical specifications and performance data
Installation and operation guide