| Parameter | Value |
|---|---|
| GTIN | 4055626503974 |
| Orderkey | 1018702 |
| (Drawings) | |
| (Mounting) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Catalog page | Page 60 (C-7-2019) |
| Packing unit | 1 |
| (Device supply) | 48 A (Single-phase) |
| ETIM 6.0 (eCl@ss) | EC002889 |
| ETIM 7.0 (eCl@ss) | EC002889 |
| Bus system (Inputs) | RS-485 |
| Custom tariff number | 85371098 |
| China RoHS (Mounting) | Environmentally Friendly Use Period = 50 |
| Conformance (Drawings) | CE-compliant |
| Product type (Drawings) | AC charging controller for private and commercial applications (EU/CN) |
| Charging mode (Drawings) | Mode 3, Case B + C |
| Housing (Connection data) | DIN 43880 |
| Connection method (Inputs) | Screw connection |
| Depth (Product definition) | 61.00 mm |
| Width (Product definition) | 162 mm |
| (Ethernet data interfaces) | SMA (male) |
| Height (Product definition) | 90 mm |
| Supply voltage (Dimensions) | 230 V |
| Transmission speed (Inputs) | 4.8 kbps ... 115.2 kbps (adjustable) |
| Frequency range (Dimensions) | 50 Hz ... 60 Hz |
| Mounting position (EMC data) | any |
| Protocols supported (Inputs) | Modbus/RTU (Master) |
| Schematic diagram (Drawings) | |
| eCl@ss 9.0 (Classifications) | 27144703 |
| Connection diagram (Drawings) | |
| Number of interfaces (Inputs) | 1 (for energy measurement device and RFID reader) |
| Dimensional drawing (Drawings) | |
| Power consumption (Dimensions) | < 10 W (maximum) |
| Assembly instructions (EMC data) | DIN rail mounting |
| Noise emission (Connection data) | EN 61000-6-3 |
| Noise immunity (Connection data) | EN 61000-6-2 |
| Rated current In (Device supply) | 32 A (Three-phase, 4x6 mm²) |
| Standards/regulations (Drawings) | IEC 61851-1 |
| Supply voltage range (Dimensions) | 100 V AC ... 240 V AC (nominal voltage range) |
| Rated frequency fn (Device supply) | ≤ 2000 Hz |
| Max. altitude (Wireless interfaces) | < 2000 m |
| SIM card (Ethernet data interfaces) | Micro-SIM |
| Frequency (Ethernet data interfaces) | 900 MHz (HSPA) |
| Impedance (Ethernet data interfaces) | 50 Ω |
| Number of supported devices (Inputs) | 2 |
| Residual current IΔn (Device supply) | 30 mA (AC) |
| Connection method (Ambient conditions) | Screw connection |
| Nominal current IN (Switching outputs) | ≤ 4 mA |
| Nominal power consumption (Dimensions) | < 3 W (No-load) |
| Tripping time for IΔn (Device supply) | < 180 ms |
| Low Voltage Directive (Connection data) | Conformance with Low Voltage Directive 2014/35/EC |
| Tripping time for 5xIΔn (Device supply) | < 20 ms |
| Degree of pollution (Wireless interfaces) | 2 IEC 60664-1 |
| Connection method (RS-485 data interfaces) | RJ45 socket |
| Degree of protection (Wireless interfaces) | IP20 |
| Input voltage range U1 (Switching outputs) | 0 V ... 3 V (Off) |
| Input voltage range U2 (Switching outputs) | 9 V ... 15 V (On) |
| Response time for 2 x IΔn (Device supply) | < 70 ms |
| Transmission speed (RS-485 data interfaces) | 10/100 Mbps |
| Description of the input (Switching outputs) | Digital input |
| Nominal differential current (Device supply) | ± 300 mA |
| Nominal input voltage UN (Switching outputs) | 12 V |
| Number of digital inputs (Switching outputs) | 5 |
| Protocols supported (RS-485 data interfaces) | Modbus/TCP |
| Transmission length (RS-485 data interfaces) | 100 m |
| Antenna connection (Ethernet data interfaces) | 1 |
| Number of interfaces (RS-485 data interfaces) | 1 |
| Transmission power (Ethernet data interfaces) | 2 W (GSM 850 (Class 4)) |
| Number of supported charging points (Drawings) | 1 |
| Protocols supported (Ethernet data interfaces) | OCPP 1.6J |
| Electromagnetic compatibility (Connection data) | Conformance with EMC Directive 2014/30/EU |
| Conductor cross section AWG (Ambient conditions) | 26 ... 16 |
| Interface description (Ethernet data interfaces) | HSPA/GSM/SPRS/EDGE mobile wireless interface for communicating with higher-level management systems using the OCPP 1.6J communication protocol |
| Conductor cross section solid (Ambient conditions) | 0.14 mm² ... 1.5 mm² |
| Ambient temperature (operation) (Wireless interfaces) | -25 °C ... 60 °C |
| Conductor cross section flexible (Ambient conditions) | 0.2 mm² ... 1 mm² |
| Max. switching current (Measuring current transducer) | 1 A (maximum) |
| Permissible humidity (operation) (Wireless interfaces) | 30 % ... 95 % (non-condensing) |
| Locking release in the event of mains failure (Drawings) | Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet |
| Maximum switching voltage (Measuring current transducer) | 12 V (Internal supply) |
| Minimum switching capacity (Measuring current transducer) | 4000 VA |
| Control of locking actuator (Measuring current transducer) | Motor switching output |
| Connection method (Measuring range of the residual current) | Connector |
| Control of charging contactor (Measuring current transducer) | Relay output C1.2 |
| Ambient temperature (storage/transport) (Wireless interfaces) | -40 °C ... 85 °C |
| Diameter of measuring coil (Measuring range of the residual current) | 15 mm |
Technical specifications and performance data
Installation and operation guide