| Parameter | Value |
|---|---|
| Feature Name | Feature Value |
| Depth (EF000049) | 114.5 mm |
| Model (EF000010) | Expansion device |
| Width (EF000008) | 22.5 mm |
| Height (EF000040) | 99 mm |
| Release-delay (EF001129) | 0 s |
| With start input (EF003342) | No |
| Control voltage 1 (EF002952) | 24 V |
| Control voltage 2 (EF002953) | 24 V |
| Evaluation inputs (EF008245) | 1-channel |
| Power consumption (EF000346) | 4.52 W |
| Supply voltage DC (EF007534) | 24 V |
| Operating voltage DC (EF008208) | 24 V |
| Rated switch current (EF006706) | 6 A |
| With muting function (EF004057) | No |
| With feedback circuit (EF003343) | Yes |
| With approval for TÜV (EFDE0031) | Yes |
| With detachable clamps (EF003340) | Yes |
| Supply voltage AC 50 Hz (EF007532) | 0 V |
| Supply voltage AC 60 Hz (EF007533) | 0 V |
| With approval for BG BIA (EF004145) | No |
| Type of control voltage 1 (EF002954) | DC |
| Type of control voltage 2 (EF002955) | DC |
| Operating voltage AC 50 Hz (EF008206) | 0 V |
| Operating voltage AC 60 Hz (EF008207) | 0 V |
| SIL according to IEC 61508 (EF009889) | 3 |
| Suitable for rail mounting (EF003972) | Yes |
| Type of electric connection (EF003961) | Screw connection |
| Voltage type (supply voltage) (EF002991) | DC |
| With approval according to UL (EF001783) | Yes |
| Voltage type (operating voltage) (EF005294) | DC |
| Suitable for monitoring of valves (EF007272) | No |
| Stop category according to IEC 60204 (EF007498) | 1 |
| Type of safety according to IEC 61496-1 (EF004105) | None |
| Suitable for monitoring of tactile sensors (EF007271) | No |
| Suitable for monitoring of magnetic switches (EF007266) | No |
| Suitable for monitoring of position switches (EF007270) | Yes |
| Performance level according to EN ISO 13849-1 (EF007399) | Level d |
| Suitable for monitoring of proximity switches (EF007267) | No |
| Suitable for monitoring of emergency-stop circuits (EF007268) | Yes |
| Number of outputs, safety related, delayed, with contact (EF003345) | 4 |
| Number of outputs, safety related, delayed, semiconductors (EF003347) | 0 |
| Number of outputs, safety related, undelayed, with contact (EF003344) | 0 |
| Number of outputs, safety related, undelayed, semiconductors (EF003346) | 0 |
| Number of outputs, signalling function, delayed, with contact (EF003349) | 1 |
| Suitable for monitoring of optoelectronic protection equipment (EF007269) | No |
| Number of outputs, signalling function, delayed, semiconductors (EF003351) | 0 |
| Number of outputs, signalling function, undelayed, with contact (EF003348) | 0 |
| Number of outputs, signalling function, undelayed, semiconductors (EF003350) | 0 |
Technical specifications and performance data