| Parameter | Value |
|---|---|
| GTIN | 4046356522632 |
| Orderkey | 2900177 |
| Catalog page | Page 270 (C-5-2017) |
| Packing unit | 1 pc |
| (Dimensions) | -25 °C ... 40 °C (corresponds to UL 508) |
| (Input data) | 1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing) |
| Country of origin | AT (Austria) |
| Color (Power supply) | green |
| Custom tariff number | 85364900 |
| (Ambient conditions) | 0.3 A ... 12 A (Range: 3 kW and 6 kW) |
| Output fuse (Input data) | 5 A (fast-blow) |
| Contact type (Input data) | 2 floating PDT contacts |
| Conformance (Power supply) | CE-compliant |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| Depth (Key Commercial Data) | 113 mm |
| Tightening torque (General) | 1 Nm |
| Width (Key Commercial Data) | 45 mm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Height (Key Commercial Data) | 90 mm |
| Conformance (Connection data) | CE-compliant |
| Function (Ambient conditions) | Underload, overload, window, winding temperature monitoring |
| Operating mode (Power supply) | 100% operating factor |
| UL, USA/Canada (Power supply) | UL applied for |
| Mounting position (Power supply) | any |
| UL, USA/Canada (Connection data) | UL applied for |
| Recovery time (Ambient conditions) | 500 ms |
| Release value (Ambient conditions) | ≤ 1.8 kΩ (Relay picks up) |
| Basic accuracy (Ambient conditions) | ± 2 % (of scale end value) |
| Overvoltage category (Power supply) | III, basic insulation (as per EN 50178) |
| Response value (Ambient conditions) | ≥ 3.6 kΩ (Relay drops out) |
| Supply voltage range (Contact side) | 110 V AC ... 500 V AC (see Power modules) |
| Assembly instructions (Power supply) | on standard DIN rail NS 35 in accordance with EN 60715 |
| Repeat accuracy (Ambient conditions) | ± 2 % |
| Weight per Piece (excluding packing) | 243.500 g |
| Conductor cross section AWG (General) | 20 ... 14 |
| Setting accuracy (Ambient conditions) | ≤ 5 % (of scale end value) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Maximum switching voltage (Input data) | 250 V AC (in acc. with IEC 60664-1) |
| Mechanical service life (Power supply) | approx. 2x 107cycles |
| Overload capacity (Ambient conditions) | 12 A permanent |
| Conductor cross section solid (General) | 0.5 mm² ... 2.5 mm² |
| Max. setting range (Ambient conditions) | 10 % ... 120 % (of PN) |
| Min. setting range (Ambient conditions) | 5 % ... 110 % (of PN) |
| Rated insulation voltage (Power supply) | 300 V (acc. to EN 50178) |
| Input current range (Ambient conditions) | 0.15 A ... 6 A (Range: 0.75 kW and 1.5 kW) |
| Input voltage range (Ambient conditions) | 0 V AC ... 480 V AC (1(N) ~, single-phase load) |
| Conductor cross section flexible (General) | 0.25 mm² ... 2.5 mm² |
| Housing insulation material (Power supply) | Polyamide PA, self-extinguishing |
| Total cold resistance (Ambient conditions) | < 1.5 kΩ |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Nominal input voltage UN (Ambient conditions) | 480 V (3 N ~ 480/277 V) |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.25 mm² |
| Interrupting rating (ohmic load) max. (Input data) | 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Maximum temperature coefficient (Ambient conditions) | ≤ 0.02 %/K |
| Setting range for response delay (Ambient conditions) | 0.1 s ... 50 s |
| Setting range for starting delay (Ambient conditions) | 1 s ... 100 s |
Technical specifications and performance data
Installation and operation guide