Service time: Monday to Friday 9:00-18:00
EMD-FL-3V-230 - EMD-FL-3V-230 2885773 PHOENIX CONTACT Monitoring relay
In Stock Hot Product

EMD-FL-3V-230

EMD-FL-3V-230 2885773 PHOENIX CONTACT Monitoring relay

$0.00USD
4648 in stock
Key Specifications
GTIN:4046356100786
Orderkey:2885773
Catalog page:Page 268 (C-5-2017)
Depth (Note):113 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356100786
Orderkey2885773
Catalog pagePage 268 (C-5-2017)
Depth (Note)113 mm
Packing unit1 pc
Width (Note)22.5 mm
(Dimensions)-25 °C ... 40 °C (corresponds to UL 508)
(Input data)1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing)
Height (Note)90 mm
(Contact side)24 V DC ... 240 V DC -20 % ... +25 %
Country of originAT (Austria)
Color (Power supply)green
Custom tariff number85364900
Output fuse (Input data)5 A (fast-blow)
Contact type (Input data)2 floating PDT contacts
Conformance (Power supply)CE-compliant
Stripping length (General)8 mm
Connection method (General)Screw connection
Tightening torque (General)1 Nm
(Standards and Regulations)No hazardous substances above threshold values
Conformance (Connection data)CE-compliant
Function (Ambient conditions)Undervoltage, window, asymmetry, phase sequence, phase failure
Operating mode (Power supply)100% operating factor
UL, USA/Canada (Power supply)UL/C-UL listed UL 508
Asymmetry (Ambient conditions)5 % ... 25% / OFF
Mounting position (Power supply)any
Noise emission (Connection data)EN 61000-6-4
Noise immunity (Connection data)EN 61000-6-2
UL, USA/Canada (Connection data)UL/C-UL listed UL 508
Recovery time (Ambient conditions)500 ms
Basic accuracy (Ambient conditions)± 5 % (of scale end value)
Overvoltage category (Power supply)III, basic insulation (as per EN 50178)
Supply voltage range (Contact side)24 V AC ... 240 V AC -15 % ... +10 %
Assembly instructions (Power supply)on standard DIN rail NS 35 in accordance with EN 60715
Repeat accuracy (Ambient conditions)≤ 2 %
Weight per Piece (excluding packing)164.900 g
Conductor cross section AWG (General)20 ... 14
Setting accuracy (Ambient conditions)≤ 5 % (of scale end value)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Maximum switching voltage (Input data)250 V AC (in acc. with IEC 60664-1)
Mechanical service life (Power supply)approx. 2x 107cycles
Conductor cross section solid (General)0.5 mm² ... 2.5 mm²
Low Voltage Directive (Connection data)Conformance with LV directive 2006/95/EC
Max. setting range (Ambient conditions)-20 % ... 30 % (From UN)
Min. setting range (Ambient conditions)-30 % ... 20 % (From UN)
Rated insulation voltage (Power supply)300 V (acc. to EN 50178)
Conductor cross section flexible (General)0.25 mm² ... 2.5 mm²
Housing insulation material (Power supply)Polyamide PA, self-extinguishing
Ambient temperature (operation) (Dimensions)-25 °C ... 55 °C
Electromagnetic compatibility (Power supply)Conformance with EMC Directive 2004/108/EC
Nominal input voltage UN (Ambient conditions)3 N ~ 230/132 V
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Conductor cross section flexible max. (General)2.5 mm²
Conductor cross section flexible min. (General)0.25 mm²
Electromagnetic compatibility (Connection data)Conformance with EMC Directive 2004/108/EC
Interrupting rating (ohmic load) max. (Input data)750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing)
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 70 °C
Maximum temperature coefficient (Ambient conditions)< 0.1 %/K
Setting range for response delay (Ambient conditions)0.1 s ... 10 s
Min setting range of the voltage threshold value (Ambient conditions)161 V AC ... 276 V AC
Max. setting range of the voltage threshold value (Ambient conditions)184 V AC ... 299 V AC

Product Description

Supervisory relay for 3-phase voltage monitoring of 160 ... 300 V AC, Undervoltage, Window, Phase Sequence, Phase Failure, Asymmetry, Long Range Power Supply, 2 Switched Contacts
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top