| Parameter | Value |
|---|---|
| GTIN | 4046356100786 |
| Orderkey | 2885773 |
| Catalog page | Page 268 (C-5-2017) |
| Depth (Note) | 113 mm |
| Packing unit | 1 pc |
| Width (Note) | 22.5 mm |
| (Dimensions) | -25 °C ... 40 °C (corresponds to UL 508) |
| (Input data) | 1250 VA (5 A/250 V AC, module not aligned, ≥ 5 mm spacing) |
| Height (Note) | 90 mm |
| (Contact side) | 24 V DC ... 240 V DC -20 % ... +25 % |
| Country of origin | AT (Austria) |
| Color (Power supply) | green |
| Custom tariff number | 85364900 |
| Output fuse (Input data) | 5 A (fast-blow) |
| Contact type (Input data) | 2 floating PDT contacts |
| Conformance (Power supply) | CE-compliant |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| Tightening torque (General) | 1 Nm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Conformance (Connection data) | CE-compliant |
| Function (Ambient conditions) | Undervoltage, window, asymmetry, phase sequence, phase failure |
| Operating mode (Power supply) | 100% operating factor |
| UL, USA/Canada (Power supply) | UL/C-UL listed UL 508 |
| Asymmetry (Ambient conditions) | 5 % ... 25% / OFF |
| Mounting position (Power supply) | any |
| Noise emission (Connection data) | EN 61000-6-4 |
| Noise immunity (Connection data) | EN 61000-6-2 |
| UL, USA/Canada (Connection data) | UL/C-UL listed UL 508 |
| Recovery time (Ambient conditions) | 500 ms |
| Basic accuracy (Ambient conditions) | ± 5 % (of scale end value) |
| Overvoltage category (Power supply) | III, basic insulation (as per EN 50178) |
| Supply voltage range (Contact side) | 24 V AC ... 240 V AC -15 % ... +10 % |
| Assembly instructions (Power supply) | on standard DIN rail NS 35 in accordance with EN 60715 |
| Repeat accuracy (Ambient conditions) | ≤ 2 % |
| Weight per Piece (excluding packing) | 164.900 g |
| Conductor cross section AWG (General) | 20 ... 14 |
| Setting accuracy (Ambient conditions) | ≤ 5 % (of scale end value) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Maximum switching voltage (Input data) | 250 V AC (in acc. with IEC 60664-1) |
| Mechanical service life (Power supply) | approx. 2x 107cycles |
| Conductor cross section solid (General) | 0.5 mm² ... 2.5 mm² |
| Low Voltage Directive (Connection data) | Conformance with LV directive 2006/95/EC |
| Max. setting range (Ambient conditions) | -20 % ... 30 % (From UN) |
| Min. setting range (Ambient conditions) | -30 % ... 20 % (From UN) |
| Rated insulation voltage (Power supply) | 300 V (acc. to EN 50178) |
| Conductor cross section flexible (General) | 0.25 mm² ... 2.5 mm² |
| Housing insulation material (Power supply) | Polyamide PA, self-extinguishing |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 55 °C |
| Electromagnetic compatibility (Power supply) | Conformance with EMC Directive 2004/108/EC |
| Nominal input voltage UN (Ambient conditions) | 3 N ~ 230/132 V |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section flexible max. (General) | 2.5 mm² |
| Conductor cross section flexible min. (General) | 0.25 mm² |
| Electromagnetic compatibility (Connection data) | Conformance with EMC Directive 2004/108/EC |
| Interrupting rating (ohmic load) max. (Input data) | 750 VA (3 A/250 V AC, module aligned, ≤ 5 mm spacing) |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Maximum temperature coefficient (Ambient conditions) | < 0.1 %/K |
| Setting range for response delay (Ambient conditions) | 0.1 s ... 10 s |
| Min setting range of the voltage threshold value (Ambient conditions) | 161 V AC ... 276 V AC |
| Max. setting range of the voltage threshold value (Ambient conditions) | 184 V AC ... 299 V AC |
Technical specifications and performance data