| Parameter | Value |
|---|---|
| GTIN | 4046356728843 |
| Orderkey | 2903246 |
| (Mounting) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Catalog page | Page 762 (C-2-2017) |
| Packing unit | 1 pc |
| Country of origin | DE (Germany) |
| Custom tariff number | 85389091 |
| China RoHS (Mounting) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Mounting) | Lead 7439-92-1 |
| (Key Commercial Data) | EN 61000-6-3 |
| Depth (Product definition) | 61.00 mm |
| Width (Product definition) | 35.6 mm |
| Height (Product definition) | 90 mm |
| Max. switching current (Inputs) | 4 A |
| Supply voltage (Connection data) | 12 V DC ±5 % |
| Conformance (Key Commercial Data) | CE-compliant |
| Degree of protection (Dimensions) | IP20 |
| Mounting position (Device supply) | any |
| Current carrying capacity (Inputs) | ≤ 4 A |
| Maximum switching voltage (Inputs) | approx. 11.5 V (Operating/capacitor voltage minus the diode voltage of ~ 0.5 V) |
| Product type (Key Commercial Data) | Locking release module in the event of mains failure for AC charging controllers for commercial applications (EU) |
| Charging mode (Key Commercial Data) | Mode 3 |
| Minimum switching capacity (Inputs) | 46 VA |
| Control of locking actuator (Inputs) | Relay output OUT+/- |
| Frequency range (Ambient conditions) | 50 Hz ... 60 Hz |
| Weight per Piece (excluding packing) | 124.000 g |
| Connection method (Switching outputs) | Screw connection |
| Supply voltage range (Connection data) | 12 V DC ±5 % |
| Charging standard (Key Commercial Data) | Type 2 |
| Nominal current IN (Ambient conditions) | approx. 5 mA |
| Max. current consumption (Connection data) | 4 mA (in idle state) |
| Current carrying capacity (Connection data) | ≤ 4 A |
| Input voltage range U1 (Ambient conditions) | -3 V ... 3 V (Off) |
| Input voltage range U2 (Ambient conditions) | -30 V ... -10 V (Locking ON) |
| Input voltage range U3 (Ambient conditions) | 10 V ... 30 V (Unlocking ON) |
| Standards/regulations (Key Commercial Data) | IEC 61851-1 |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 60 °C |
| Nominal input voltage UN (Ambient conditions) | 12 V |
| Number of digital inputs (Ambient conditions) | 1 |
| Nominal power consumption (Ambient conditions) | < 0.5 W (No-load) |
| Conductor cross section AWG (Switching outputs) | 24 ... 12 |
| Conductor cross section solid (Switching outputs) | 0.2 mm² ... 4 mm² |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 60 °C |
| Conductor cross section flexible (Switching outputs) | 0.2 mm² ... 2.5 mm² |
| Number of supported charging points (Key Commercial Data) | 1 |
| Locking release in the event of mains failure (Key Commercial Data) | Integrated release function of the locking actuator for disconnection of Infrastructure Plug and Infrastructure Socket Outlet |
Technical specifications and performance data