| Parameter | Value |
|---|---|
| GTIN | 4055626725222 |
| Orderkey | 1064922 |
| (Drawings) | |
| Catalog page | Page 262 (C-4-2019) |
| Depth (Note) | 159 mm |
| Packing unit | 1 |
| Width (Note) | 36 mm |
| (Input data) | < 0.1 % (change in input voltage ±10 %) |
| Height (Note) | 160 mm |
| (Output data) | > 620000 h (60 °C) |
| ETIM 5.0 (eCl@ss) | EC002540 |
| ETIM 6.0 (eCl@ss) | EC002540 |
| ETIM 7.0 (eCl@ss) | EC002540 |
| Custom tariff number | 85044030 |
| (Ambient conditions) | typ. 20 ms (500 V AC) |
| Derating (Input data) | > 60 °C ... 70 °C (2.5%/K) |
| REACh SVHC (EMC data) | Lead 7439-92-1 |
| (Conformance/approvals) | 2 kV (Test Level 1 - asymmetrical) |
| Efficiency (Output data) | typ. 91 % (400 V AC) |
| Net weight (Output data) | 0.7 kg |
| UL approvals (Standards) | UL Listed UL 61010-2-201 |
| Output power (Input data) | 120 W |
| Climatic class (Dimensions) | 3K3 (in acc. with EN 60721) |
| Connection method (General) | Snap-on connection |
| Residual ripple (Input data) | ≤ 20 mVPP |
| eCl@ss 6.0 (Classifications) | 27049000 |
| eCl@ss 7.0 (Classifications) | 27049002 |
| eCl@ss 8.0 (Classifications) | 27049002 |
| eCl@ss 9.0 (Classifications) | 27040701 |
| Input (Conformance/approvals) | 3 kV (Test Level 3 - symmetrical) |
| Control deviation (Input data) | < 1 % (change in load, static 10 % ... 90 %) |
| Output (Conformance/approvals) | 1 kV (Test Level 2 - symmetrical) |
| Protection class (Output data) | II (in closed control cabinet) |
| Signal (Conformance/approvals) | 1 kV (Test Level 1 - symmetrical) |
| Input fuse (Ambient conditions) | 3.15 A (internal (device protection), slow-blow) |
| Voltage (Conformance/approvals) | 230 V AC |
| Comments (Conformance/approvals) | Criterion A |
| Degree of pollution (Dimensions) | 2 |
| Installation height (Dimensions) | ≤ 4000 m (> 2000 m, Derating: 10 %/1000 m) |
| Connection in series (Input data) | yes |
| Degree of protection (Dimensions) | IP20 |
| Frequency (Conformance/approvals) | 50 Hz |
| Degree of protection (Output data) | IP20 |
| Typical response time (Input data) | < 1 s |
| Utilization restriction (Drawings) | EMC: class A product, see manufacturer's declaration in the download area |
| Assembly instructions (Output data) | Cross Power System |
| Connection in parallel (Input data) | Yes, for redundancy and increased capacity |
| Criterion A (Conformance/approvals) | Normal operating behavior within the specified limits. |
| Criterion B (Conformance/approvals) | Temporary impairment to operational behavior that is corrected by the device itself. |
| Inrush current (Ambient conditions) | ≤ 22 A (typical) |
| Nominal output voltage (Input data) | 24 V DC ±1 % |
| Voltage dip (Conformance/approvals) | 0 % |
| Voltage dips (Conformance/approvals) | EN 61000-4-11 |
| Noise emission (Conformance/approvals) | EN 55016 |
| AC frequency range (Ambient conditions) | 50 Hz ... 60 Hz |
| Additional text (Conformance/approvals) | Test Level 2 |
| Dynamic Boost (IDyn.Boost) (Input data) | 7.5 A (5 s) |
| Frequency range (Conformance/approvals) | 2 GHz ... 3 GHz |
| Type of protection (Ambient conditions) | Transient surge protection |
| Current consumption (Ambient conditions) | 3x 0.4 A (400 V AC) |
| Discharge in air (Conformance/approvals) | 8 kV (Test Level 4) |
| Input voltage range (Ambient conditions) | 3x 400 V AC ... 500 V AC -20 % ....+15 % |
| MTBF (IEC 61709, SN 29500) (Output data) | > 2300000 h (25 °C) |
| Nominal output current (IN) (Input data) | 5 A |
| Contact discharge (Conformance/approvals) | 6 kV (Test Level 4) |
| Mains buffering time (Ambient conditions) | typ. 20 ms (400 V AC) |
| Number of periods (Conformance/approvals) | 1 period |
| Power loss nominal load max. (Input data) | < 12 W (480 V AC) |
| Stripping length (Connection data, input) | 10 mm |
| Connection method (Connection data, input) | Push-in connection |
| Stripping length (Connection data, output) | 8 mm |
| Connection method (Connection data, output) | Push-in connection |
| Power factor (cos phi) (Ambient conditions) | 0.55 |
| Test field strength (Conformance/approvals) | 10 V/m (Test Level 3) |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Discharge current to PE (Ambient conditions) | < 0.25 mA |
| Insulation voltage input/output (Output data) | 3 kV AC (type test) |
| Low Voltage Directive (Conformance/approvals) | Conformance with Low Voltage Directive 2014/35/EC |
| Nominal power consumption (Ambient conditions) | 243.6 VA |
| Electrostatic discharge (Conformance/approvals) | EN 61000-4-2 |
| Fast transients (burst) (Conformance/approvals) | EN 61000-4-4 |
| Conducted noise emission (Conformance/approvals) | EN 55016 |
| Electromagnetic HF field (Conformance/approvals) | EN 61000-4-3 |
| Nominal input voltage range (Ambient conditions) | 3x 400 V AC ... 500 V AC |
| Protective circuit/component (Ambient conditions) | Varistor |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 85 °C |
| Electromagnetic compatibility (Conformance/approvals) | Conformance with EMC Directive 2014/30/EU |
| Setting range of the output voltage (USet) (Input data) | 24 V DC ... 28 V DC (> 24 V DC, constant capacity restricted) |
| Conductor cross section AWG max. (Connection data, input) | 12 |
| Conductor cross section AWG min. (Connection data, input) | 24 |
| Standard - Safe isolation (Connection data for signaling) | DIN VDE 0100-410 |
| Conductor cross section AWG max. (Connection data, output) | 16 |
| Conductor cross section AWG min. (Connection data, output) | 24 |
| Conductor cross section solid max. (Connection data, input) | 4 mm² |
| Conductor cross section solid min. (Connection data, input) | 0.2 mm² |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % (at 25 °C, non-condensing) |
| Maximum power dissipation in no-load condition (Input data) | < 1 W (400 V AC) |
| Conductor cross section solid max. (Connection data, output) | 1.5 mm² |
| Conductor cross section solid min. (Connection data, output) | 0.2 mm² |
| Standard - Electrical safety (Connection data for signaling) | IEC 61010-1 (SELV) |
| Recommended breaker for input protection (Ambient conditions) | 6 A ... 16 A (AC: Characteristics B, C, D, K) |
| Conductor cross section flexible max. (Connection data, input) | 2.5 mm² |
| Conductor cross section flexible min. (Connection data, input) | 0.2 mm² |
| Conductor cross section flexible max. (Connection data, output) | 1.5 mm² |
| Conductor cross section flexible min. (Connection data, output) | 0.2 mm² |
| Protection against overvoltage at the output (OVP) (Input data) | ≤ 30 V DC |
| Standard - Safety of transformers (Connection data for signaling) | EN 61558-2-16 (air clearances and creepage distances only) |
| EMC requirements for noise immunity (Connection data for signaling) | EN 61000-6-2 |
| Standard – Safety extra-low voltage (Connection data for signaling) | IEC 61010 (SELV) / (PELV) |
| Standard – Limitation of mains harmonic currents (Connection data for signaling) | EN 61000-3-2 |
| Standard – Electronic equipment for use in electrical power installations and their assembly into electrical power installations (Connection data for signaling) | EN 50178/VDE 0160 (PELV) |
Technical specifications and performance data
Installation and operation guide