Service time: Monday to Friday 9:00-18:00
ELR-H51-9-BUSBAR-COMPACT-SET - ELR-H51-9-BUSBAR-COMPACT-SET 2904337 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR-H51-9-BUSBAR-COMPACT-SET

ELR-H51-9-BUSBAR-COMPACT-SET 2904337 PHOENIX CONTACT Hybrid motor starter

$0.00USD
3939 in stock
Key Specifications
GTIN:4046356802970
Note:Made to Order (non-returnable)
Orderkey:2904337
(UL data):Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356802970
NoteMade to Order (non-returnable)
Orderkey2904337
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 33 (C-5-2017)
Packing unit1 pc
(Input data)Short-circuit protection
(Device supply)19.2 V (“1” signal)
Torque (General)0.5 Nm ... 0.6 Nm
Country of originDE (Germany)
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
(Ambient conditions)30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
(Key Commercial Data)Reverse polarity protection
Screw thread (General)M3
FLA (Ambient conditions)6.5 A (480 V AC)
Output name (Input data)AC output
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Cooling time (Input data)20 min. (for auto reset)
SCCR (Ambient conditions)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
(Output data load output)2 A (24 V, DC13)
Input name (Device supply)Control input right/left
Stripping length (General)8 mm
Connection method (General)Screw connection
(Standards and Regulations) II (2) D [Ex t] [Ex p]
Leakage current (Input data)0 mA
Mains frequency (Input data)50/60 Hz
(Insulation characteristics) II (2) D [Ex t] [Ex p]
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Overvoltage category (UL data)III
Indication (Overspeed tripping)Red LED
Load current range (Input data)1.5 A ... 9 A
Switching level (Device supply)< 5 V DC (For EMERGENCY STOP)
Type of protection (Input data)Surge protection
ATEX (Standards and Regulations) II (2) G [Ex e] [Ex d] [Ex px]
ATEX (Insulation characteristics) II (2) G [Ex e] [Ex d] [Ex px]
Category code (Ambient conditions)NLDX / NRNT
Mounting type (Overspeed tripping)Bus bar mounting
Rated insulation voltage (UL data)500 V
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Operating mode (Overspeed tripping)100% operating factor
REACh SVHC (Approvals/conformities)Lead 7439-92-1
Status display (Overspeed tripping)Yellow LED
Switching threshold (Device supply)9.6 V (“0” signal)
Operating voltage range (Input data)42 V AC ... 550 V AC
Torque (Connection data, input side)0.5 Nm ... 0.6 Nm
Weight per Piece (excluding packing)350.000 g
Conductor cross section AWG (General)24 ... 14
Output name (Output data load output)Acknowledge output
Typical turn-off time (Device supply)< 30 ms
Contact type (Output data load output)1 PDT
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Group installation (Ambient conditions)20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Rated operating voltage Ue (Input data)500 V AC
Designation (Insulation characteristics)Standards/regulations
Response time (Output data reply output)< 2 s
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Triggering voltage range (Device supply)19.2 V DC ... 30 V DC
Type of protection (Key Commercial Data)Surge protection
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated actuating current IC (Device supply)5 mA
Rated actuating voltage UC (Device supply)24 V DC
Screw thread (Connection data, input side)M3
UL certificate (Standards and Regulations)NLDX.E228652
Operate threshold (Output data reply output)> 45 A
Connection name (Connection data, input side)Load circuit
Maximum power dissipation (Overspeed tripping)7 W
Minimum power dissipation (Overspeed tripping)0.88 W
Operating voltage display (Overspeed tripping)Green LED
Stripping length (Connection data, input side)8 mm
Connection method (Connection data, input side)Screw connection
Control supply voltage range (Key Commercial Data)19.2 V DC ... 30 V DC
Standards/regulations (Insulation characteristics)IEC 60947-1
Degree of protection (Connection data, output side)IP20
Rated control supply current IS (Key Commercial Data)40 mA
Category acc. to EN ISO 13849 (Standards and Regulations)3 (Safe shutdown)
Conductor cross section AWG (Connection data, input side)24 ... 14
Conductor cross section solid (Connection data, input side)0.2 mm² ... 2.5 mm²
EU-type examination certificate (Standards and Regulations)PTB 07 ATEX 3145
Rated control circuit supply voltage US (Key Commercial Data)24 V DC
Ambient temperature (operation) (Connection data, output side)-25 °C ... 70 °C (observe derating)
Conductor cross section flexible (Connection data, input side)0.2 mm² ... 2.5 mm²
Trigger characteristic in acc. with IEC 60947-4-2 (Input data)Class 10A
Performance level according to ISO 13849 (Standards and Regulations)e (Safe shutdown)
Ambient temperature (storage/transport) (Connection data, output side)-40 °C ... 80 °C
Switching capacity according to IEC 60947-5-1 (Output data load output)3 A (230 V, AC15)
Safety Integrity Level according to IEC 61508 (Standards and Regulations)≤ 3 (Safe shutdown)

Product Description

Complete package, consisting of ELR H51-IESSC-24DC500AC-9 and EM RI-ADAPTER COMPACT, for 60 mm busbar mounting
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Technical Details

Short-circuit-proof hybrid motor starter for reversing 3~ AC motors up to 550 V AC, with 24 V DC input, 9 A output current, emergency stop function, and adjustable overload shutdown. Can only be used with EM-RD adapter, EM-RI adapter or power distribution board.

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top