Service time: Monday to Friday 9:00-18:00
ELR H51-2.4-DIN-RAIL-SET - ELR H51-2.4-DIN-RAIL-SET 2902953 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR H51-2.4-DIN-RAIL-SET

ELR H51-2.4-DIN-RAIL-SET 2902953 PHOENIX CONTACT Hybrid motor starter

$0.00USD
3528 in stock
Key Specifications
:Reverse polarity protection; Parallel polarity protection diode
FLA:2.4 A (480 V AC)
Note:Confirmation: floating change-over contact, signal contact
SCCR:100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Reverse polarity protection; Parallel polarity protection diode
FLA2.4 A (480 V AC)
NoteConfirmation: floating change-over contact, signal contact
SCCR100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Depth142.6 mm
Width22.5 mm
Height185 mm
Altitude≤ 2000 m
Input nameControl input right/left
CertificatePTB 07 ATEX 3145
Cooling time20 min. (for auto reset)
Product typeHybrid motor starters
Screw threadM3
Assembly notealignable, for spacing see derating
Category codeNLDX / NRNT
Mounting typeDIN rail mounting
Identification II (2) G [Ex e] [Ex d] [Ex px]
Operating mode100% operating factor
Product familyCONTACTRON
Status displayLED (yellow)
Leakage current0 mA
Mains frequency50/60 Hz
Switching level< 5 V DC (For EMERGENCY STOP)
Article revision04
Error indicationRed LED
Number of phases3
Stripping length8 mm
Connection methodScrew connection
Coordination type2
Mounting positionvertical (horizontal DIN rail, motor output below)
Tightening torque0.5 Nm ... 0.6 Nm
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Load current range180 mA ... 2.4 A (see to derating)
Motor starter typeReversing starter
Protective circuitSurge protection
Degree of pollution2
Rated surge voltage6 kV
Switching frequency≤ 2 Hz (Load-dependent)
Switching threshold9.6 V (“0” signal)
Degree of protectionIP20
Overvoltage categoryIII
Standards/regulationsIEC 60947-1
Typical turn-off time< 30 ms
Contact switching type1 changeover contact
Operating voltage range42 V AC ... 550 V AC
Rated insulation voltage500 V
Triggering voltage range19.2 V DC ... 30 V DC
Maximum power dissipation4.1 W
Minimum power dissipation0.88 W
Operating voltage displayGreen LED
Rated actuating current IC5 mA
Rated actuating voltage UC24 V DC
Rated operating voltage Ue500 V AC
Conductor cross section AWG24 ... 14
Control supply voltage range19.2 V DC ... 30 V DC
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Rated control supply current IS40 mA
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Rated control circuit supply voltage US24 V DC
Maximum power dissipation for nominal condition4.4 W
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Switching capacity in accordance with IEC 60947-5-13 A (230 V, AC15)
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC

Product Description

Complete package consisting of ELR H51-IESSC-24DC500AC-2 and EM-RD ADAPTER for mounting on 35 mm symmetrical rails.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top