| Parameter | Value |
|---|---|
| GTIN | 4046356802390 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2904333 |
| (UL data) | Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
| Catalog page | Page 33 (C-5-2017) |
| Packing unit | 1 pc |
| (Input data) | Short-circuit protection |
| (Device supply) | 19.2 V (“1” signal) |
| Torque (General) | 0.5 Nm ... 0.6 Nm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85371098 |
| Insulation (UL data) | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| (Ambient conditions) | 30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded) |
| Designation (UL data) | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
| (Key Commercial Data) | Reverse polarity protection |
| Screw thread (General) | M3 |
| FLA (Ambient conditions) | 0.6 A (480 V AC) |
| Output name (Input data) | AC output |
| (Approvals/conformities) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection name (General) | Control circuits |
| Cooling time (Input data) | 20 min. (for auto reset) |
| SCCR (Ambient conditions) | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
| (Output data load output) | 2 A (24 V, DC13) |
| Input name (Device supply) | Control input right/left |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| (Standards and Regulations) | II (2) D [Ex t] [Ex p] |
| Leakage current (Input data) | 0 mA |
| Mains frequency (Input data) | 50/60 Hz |
| (Insulation characteristics) | II (2) D [Ex t] [Ex p] |
| Degree of pollution (UL data) | 2 |
| Rated surge voltage (UL data) | 6 kV |
| Overvoltage category (UL data) | III |
| Load current range (Input data) | 75 mA ... 600 mA |
| Switching level (Device supply) | < 5 V DC (For EMERGENCY STOP) |
| Type of protection (Input data) | Surge protection |
| ATEX (Standards and Regulations) | II (2) G [Ex e] [Ex d] [Ex px] |
| ATEX (Insulation characteristics) | II (2) G [Ex e] [Ex d] [Ex px] |
| Category code (Ambient conditions) | NLDX / NRNT |
| Rated insulation voltage (UL data) | 500 V |
| China RoHS (Approvals/conformities) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Approvals/conformities) | Lead 7439-92-1 |
| Switching threshold (Device supply) | 9.6 V (“0” signal) |
| Operating voltage range (Input data) | 42 V AC ... 550 V AC |
| Torque (Connection data, input side) | 0.5 Nm ... 0.6 Nm |
| Weight per Piece (excluding packing) | 350.000 g |
| Conductor cross section AWG (General) | 24 ... 14 |
| Indication (Output data reply output) | Red LED |
| Output name (Output data load output) | Acknowledge output |
| Typical turn-off time (Device supply) | < 30 ms |
| Contact type (Output data load output) | 1 PDT |
| Conductor cross section solid (General) | 0.2 mm² ... 2.5 mm² |
| Group installation (Ambient conditions) | 20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded) |
| Rated operating voltage Ue (Input data) | 500 V AC |
| Designation (Insulation characteristics) | Standards/regulations |
| Mounting type (Output data reply output) | Bus bar mounting |
| Triggering voltage range (Device supply) | 19.2 V DC ... 30 V DC |
| Type of protection (Key Commercial Data) | Surge protection |
| Operating mode (Output data reply output) | 100% operating factor |
| Status display (Output data reply output) | Yellow LED |
| Conductor cross section flexible (General) | 0.2 mm² ... 2.5 mm² |
| Rated actuating current IC (Device supply) | 5 mA |
| Rated actuating voltage UC (Device supply) | 24 V DC |
| Screw thread (Connection data, input side) | M3 |
| Mounting position (Output data reply output) | vertical (horizontal DIN rail, motor output below) |
| Connection name (Connection data, input side) | Load circuit |
| Stripping length (Connection data, input side) | 8 mm |
| Switching frequency (Output data reply output) | ≤ 2 Hz (Load-dependent) |
| Connection method (Connection data, input side) | Screw connection |
| Assembly instructions (Output data reply output) | alignable, for spacing see derating |
| Control supply voltage range (Key Commercial Data) | 19.2 V DC ... 30 V DC |
| Standards/regulations (Insulation characteristics) | IEC 60947-1 |
| Degree of protection (Connection data, output side) | IP20 |
| Maximum power dissipation (Output data reply output) | 2.5 W |
| Minimum power dissipation (Output data reply output) | 0.88 W |
| Operating voltage display (Output data reply output) | Green LED |
| Rated control supply current IS (Key Commercial Data) | 40 mA |
| Category acc. to EN ISO 13849 (Standards and Regulations) | 3 (Safe shutdown) |
| Conductor cross section AWG (Connection data, input side) | 24 ... 14 |
| Conductor cross section solid (Connection data, input side) | 0.2 mm² ... 2.5 mm² |
| EU-type examination certificate (Standards and Regulations) | PTB 07 ATEX 3145 |
| Rated control circuit supply voltage US (Key Commercial Data) | 24 V DC |
| Ambient temperature (operation) (Connection data, output side) | -25 °C ... 70 °C (observe derating) |
| Conductor cross section flexible (Connection data, input side) | 0.2 mm² ... 2.5 mm² |
| Trigger characteristic in acc. with IEC 60947-4-2 (Input data) | Class 10A |
| Performance level according to ISO 13849 (Standards and Regulations) | e (Safe shutdown) |
| Ambient temperature (storage/transport) (Connection data, output side) | -40 °C ... 80 °C |
| Switching capacity according to IEC 60947-5-1 (Output data load output) | 3 A (230 V, AC15) |
| Safety Integrity Level according to IEC 61508 (Standards and Regulations) | ≤ 3 (Safe shutdown) |