Key Specifications
:Reverse polarity protection
FLA:6.5 A (500 V AC)
SCCR:100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Depth:114 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Reverse polarity protection
FLA6.5 A (500 V AC)
SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Depth114 mm
Width22.5 mm
Height107 mm
Altitude≤ 2000 m
Input nameControl input right/left
CertificateUKCA-compliant
Product typeHybrid motor starters
Screw threadM3
Assembly notealignable, for spacing see derating
Category codeNLDX / NRNT
Mounting typeDIN rail mounting
Operating mode100% operating factor
Product familyCONTACTRON
Status displayLED (yellow)
Leakage current0 mA
Mains frequency50/60 Hz
Article revision08
Number of phases3
Stripping length8 mm
Connection methodScrew connection
Coordination type1
Mounting positionvertical (horizontal DIN rail, motor output below)
Tightening torque0.5 Nm ... 0.6 Nm
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Load current range0 A ... 9 A (see to derating)
Motor starter typeReversing starter
Protective circuitSurge protection
Degree of pollution2
Rated surge voltage6 kV
Switching frequency≤ 2 Hz (Load-dependent)
Switching threshold9.6 V (“0” signal)
Degree of protectionIP20
Overvoltage categoryIII
Standards/regulationsIEC 60947-1
Typical turn-off time< 30 ms
Operating voltage range42 V AC ... 550 V AC
Rated insulation voltage500 V
Triggering voltage range19.2 V DC ... 30 V DC
Maximum power dissipation14.6 W
Minimum power dissipation1.1 W
Operating voltage displayGreen LED
Rated actuating current IC5 mA (Input type 1)
Rated actuating voltage UC24 V DC
Rated operating current Ie9 A (AC-51)
Rated operating voltage Ue500 V AC
Conductor cross section AWG24 ... 14
Control supply voltage range19.2 V DC ... 30 V DC
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Rated control supply current IS40 mA
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Rated control circuit supply voltage US24 V DC
Maximum power dissipation for nominal condition13.5 W
Trigger characteristic in acc. with IEC 60947-4-2-
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC

Product Description

Hybrid start controller for reversing 3~ AC motors up to 500 V AC and 9 A output current, with a control voltage of 24 V DC and screw connection.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top