| Parameter | Value |
|---|---|
| GTIN | 4055626406671 |
| Orderkey | 2908693 |
| (General) | 5 lbf-in. ... 7 lbf-in. |
| (UL data) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| (Drawings) | |
| Catalog page | Page 27 (C-5-2019) |
| Packing unit | 1 pc |
| (Input data) | 7 A (AC-53a) |
| (Device supply) | 19.2 V (“1” signal) |
| Depth (Drawings) | 114 mm |
| Torque (General) | 0.5 Nm ... 0.6 Nm |
| Width (Drawings) | 22.5 mm |
| Country of origin | DE (Germany) |
| ETIM 2.0 (eCl@ss) | EC001037 |
| ETIM 3.0 (eCl@ss) | EC001037 |
| ETIM 4.0 (eCl@ss) | EC001037 |
| ETIM 5.0 (eCl@ss) | EC001037 |
| ETIM 6.0 (eCl@ss) | EC001037 |
| ETIM 7.0 (eCl@ss) | EC001037 |
| Height (Drawings) | 107 mm |
| (Connection data) | 5 lbf-in. ... 7 lbf-in. |
| UNSPSC 13.2 (ETIM) | 25173902 |
| UNSPSC 18.0 (ETIM) | 25173902 |
| UNSPSC 19.0 (ETIM) | 25173902 |
| UNSPSC 20.0 (ETIM) | 25173902 |
| UNSPSC 21.0 (ETIM) | 25173902 |
| (Connection data 2) | Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC |
| China RoHS (UL data) | Environmentally Friendly Use Period = 50 |
| Custom tariff number | 85371098 |
| REACh SVHC (UL data) | Lead 7439-92-1 |
| (Ambient conditions) | Reverse polarity protection |
| Screw thread (General) | M3 |
| (Conformance/approvals) | 5 hp (277 V AC / 480 V AC) |
| Output name (Input data) | AC output |
| Torque (Connection data) | 0.5 Nm ... 0.6 Nm |
| Connection name (General) | Control circuits |
| Cooling time (Input data) | 20 min. (for auto reset) |
| Input name (Device supply) | Control input right/left |
| Stripping length (General) | 8 mm |
| Connection method (General) | Screw connection |
| FLA (Conformance/approvals) | 7.6 A (480 V AC) |
| (Standards and Regulations) | NRNT.E172140 |
| Leakage current (Input data) | 0 mA |
| Mains frequency (Input data) | 50/60 Hz |
| SCCR (Conformance/approvals) | 100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault))) |
| eCl@ss 4.0 (Classifications) | 27021100 |
| eCl@ss 4.1 (Classifications) | 27021100 |
| eCl@ss 5.0 (Classifications) | 27024000 |
| eCl@ss 5.1 (Classifications) | 27024000 |
| eCl@ss 6.0 (Classifications) | 27024000 |
| eCl@ss 7.0 (Classifications) | 27024002 |
| eCl@ss 8.0 (Classifications) | 27024002 |
| eCl@ss 9.0 (Classifications) | 27370905 |
| (Insulation characteristics) | EN 60947-4-2 |
| Maximum altitude (Dimensions) | ≤ 2000 m |
| Insulation (Connection data 2) | Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC |
| Note (Output data load output) | Confirmation: floating change-over contact, signal contact |
| Screw thread (Connection data) | M3 |
| Designation (Connection data 2) | Isolation characteristics between the control input and control supply voltage to auxiliary circuit |
| Indication (Overspeed tripping) | Red LED |
| Load current range (Input data) | 1.5 A ... 9 A |
| Connection name (Connection data) | Load circuit |
| Degree of protection (Dimensions) | IP20 |
| Mounting type (Overspeed tripping) | DIN rail mounting |
| Stripping length (Connection data) | 8 mm |
| Type of protection (Device supply) | Reverse polarity protection |
| Connection method (Connection data) | Screw connection |
| Operating mode (Overspeed tripping) | 100% operating factor |
| Status display (Overspeed tripping) | Yellow LED |
| Switching threshold (Device supply) | 9.6 V (“0” signal) |
| Operating voltage range (Input data) | 42 V AC ... 550 V AC |
| Weight per Piece (excluding packing) | 320.000 g |
| Category code (Conformance/approvals) | NLDX / NRNT |
| Conductor cross section AWG (General) | 24 ... 14 |
| Output name (Output data load output) | Acknowledge output |
| Typical turn-off time (Device supply) | < 30 ms |
| Contact type (Output data load output) | 1 PDT |
| Mounting position (Overspeed tripping) | vertical (horizontal DIN rail, motor output below) |
| Certificate (Standards and Regulations) | NLDX.E228652 |
| Conductor cross section solid (General) | 0.2 mm² ... 2.5 mm² |
| Degree of pollution (Connection data 2) | 2 |
| Designation (Standards and Regulations) | UL approval |
| Rated operating current Ie (Input data) | 9 A (AC-51) |
| Rated operating voltage Ue (Input data) | 500 V AC |
| Rated surge voltage (Connection data 2) | 6 kV |
| Type of protection (Ambient conditions) | Surge protection |
| Designation (Insulation characteristics) | Standards/regulations |
| Overvoltage category (Connection data 2) | III |
| Response time (Output data reply output) | < 0.5 s |
| Switching frequency (Overspeed tripping) | ≤ 2 Hz (Load-dependent) |
| Triggering voltage range (Device supply) | 19.2 V DC ... 30 V DC |
| Assembly instructions (Overspeed tripping) | alignable, for spacing see derating |
| Conductor cross section flexible (General) | 0.2 mm² ... 2.5 mm² |
| Group installation (Conformance/approvals) | 20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded) |
| Horsepower ratings (Conformance/approvals) | 2 hp (120 V AC / 208 V AC) |
| Rated actuating current IC (Device supply) | 7 mA |
| Rated actuating voltage UC (Device supply) | 24 V DC |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C (observe derating) |
| Operate threshold (Output data reply output) | > 60 A |
| Rated insulation voltage (Connection data 2) | 550 V |
| Conductor cross section AWG (Connection data) | 24 ... 14 |
| Maximum power dissipation (Overspeed tripping) | 7 W |
| Minimum power dissipation (Overspeed tripping) | 0.88 W |
| Operating voltage display (Overspeed tripping) | Green LED |
| Conductor cross section solid (Connection data) | 0.2 mm² ... 2.5 mm² |
| Control supply voltage range (Ambient conditions) | 19.2 V DC ... 30 V DC |
| Conductor cross section flexible (Connection data) | 0.2 mm² ... 2.5 mm² |
| Standards/regulations (Insulation characteristics) | EN 60947-1 |
| Ambient temperature (storage/transport) (Dimensions) | -40 °C ... 80 °C |
| Rated control supply current IS (Ambient conditions) | 60 mA |
| Ambient temperature (operation) (Conformance/approvals) | -25 °C ... 55 °C |
| Rated control circuit supply voltage US (Ambient conditions) | 24 V DC |
| Trigger characteristic in acc. with IEC 60947-4-2 (Input data) | Class 10 (≤ 3 A) |
| Switching capacity according to IEC 60947-5-1 (Output data load output) | 2 A (24 V, DC13) |
Technical specifications and performance data
Installation and operation guide