Service time: Monday to Friday 9:00-18:00
ELR H5-I-PT-SWD/500AC-06 - ELR H5-I-PT-SWD/500AC-06 2905073 PHOENIX CONTACT Networkable hybrid motor starter for reversing 3~ AC motors..
In Stock Hot Product

ELR H5-I-PT-SWD/500AC-06

ELR H5-I-PT-SWD/500AC-06 2905073 PHOENIX CONTACT Networkable hybrid motor starter for reversing 3~ AC motors..

$0.00USD
4134 in stock
Key Specifications
GTIN:4046356916806
Note:Made to Order (non-returnable)
(Note):Reverse polarity protection
Orderkey:2905073
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356916806
NoteMade to Order (non-returnable)
(Note)Reverse polarity protection
Orderkey2905073
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 23 (C-5-2017)
Packing unit1 pc
(Dimensions)30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded)
(Device supply)0.6 A (AC-53a)
FLA (Dimensions)0.6 A (480 V AC)
Country of originDE (Germany)
SCCR (Dimensions)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Type of protection (Note)Surge protection
Category code (Dimensions)NLDX / NRNT
Depth (Ambient conditions)113.7 mm
Stripping length (General)10 mm
Width (Ambient conditions)22.5 mm
Connection method (General)Push-in connection
Height (Ambient conditions)107.4 mm
Output name (Device supply)AC output
(Standards and Regulations)NRNT.E172140
Cooling time (Device supply)20 min. (for auto reset)
(Insulation characteristics)EN 60947-4-2
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Overvoltage category (UL data)III
Group installation (Dimensions)20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Horsepower ratings (Dimensions)-
Indication (Overspeed tripping)Red LED
Leakage current (Device supply)0 mA
Mains frequency (Device supply)50/60 Hz
Load current range (Device supply)75 mA ... 600 mA (see to derating)
Mounting type (Overspeed tripping)DIN rail mounting
Rated insulation voltage (UL data)550 V
Type of note (Key Commercial Data)Notes on operation
Type of protection (Device supply)Surge protection
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Control supply voltage range (Note)19.2 V DC ... 30 V DC
Operating mode (Overspeed tripping)100% operating factor
Status display (Overspeed tripping)Yellow LED
Weight per Piece (excluding packing)290.000 g
Conductor cross section AWG (General)24 ... 14
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Rated control supply current IS (Note)60 mA
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Operating voltage range (Device supply)42 V AC ... 550 V AC
Response time (Output data load output)< 0.5 s
Designation (Insulation characteristics)Standards/regulations
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated operating current Ie (Device supply)0.6 A (AC-51)
Rated operating voltage Ue (Device supply)500 V AC
UL certificate (Standards and Regulations)NLDX.E228652
Operate threshold (Output data load output)> 10 A
Connection name (Connection data, input side)Load circuit
Maximum power dissipation (Overspeed tripping)2.5 W
Minimum power dissipation (Overspeed tripping)0.88 W
Operating voltage display (Overspeed tripping)Green LED
Rated control circuit supply voltage US (Note)24 V DC
Stripping length (Connection data, input side)10 mm
Connection method (Connection data, input side)Push-in connection
Standards/regulations (Insulation characteristics)IEC 60947-1
Degree of protection (Connection data, output side)IP20
Conductor cross section AWG (Connection data, input side)24 ... 14
Conductor cross section solid (Connection data, input side)0.2 mm² ... 2.5 mm²
Ambient temperature (operation) (Connection data, output side)-5 °C ... 55 °C (observe derating)
Conductor cross section flexible (Connection data, input side)0.2 mm² ... 2.5 mm²
Trigger characteristic in acc. with IEC 60947-4-2 (Device supply)Class 10
Ambient temperature (storage/transport) (Connection data, output side)-40 °C ... 80 °C

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide