Service time: Monday to Friday 9:00-18:00
ELR H3-IES-SC/500AC-06-IFS - ELR H3-IES-SC/500AC-06-IFS 2905154 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR H3-IES-SC/500AC-06-IFS

ELR H3-IES-SC/500AC-06-IFS 2905154 PHOENIX CONTACT Hybrid motor starter

$0.00USD
4269 in stock
Key Specifications
GTIN:4046356920278
Note:Made to Order (non-returnable)
Orderkey:2905154
(UL data):Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356920278
NoteMade to Order (non-returnable)
Orderkey2905154
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 26 (C-5-2017)
Packing unit1 pc
(Input data)0.6 A (AC-53a)
(Device supply)19.2 V (“1” signal)
Torque (General)0.5 Nm ... 0.6 Nm (5-7 lbs-in)
Country of originDE (Germany)
(Connection data 2)30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded)
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
(Ambient conditions)Reverse polarity protection
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Screw thread (General)M3
FLA (Connection data 2)0.6 A (480 V AC)
Output name (Input data)AC output
SCCR (Connection data 2)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Cooling time (Input data)20 min. (for auto reset)
Input name (Device supply)Enable input
Stripping length (General)8 mm
Torque (Connection data 1)0.5 Nm ... 0.6 Nm (5-7 lbs-in)
Connection method (General)Screw connection
Depth (Key Commercial Data)113.7 mm
Width (Key Commercial Data)22.5 mm
(Standards and Regulations)NRNT.E172140
Height (Key Commercial Data)106.6 mm
Leakage current (Input data)0 mA
Mains frequency (Input data)50/60 Hz
(Insulation characteristics) II (2) D [Ex t] [Ex p]
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Overvoltage category (UL data)III
Indication (Overspeed tripping)Red LED
Load current range (Input data)75 mA ... 600 mA (see to derating)
Switching level (Device supply)< 5 V DC (For EMERGENCY STOP)
Type of protection (Input data)Surge protection
ATEX (Standards and Regulations) II (2) G [Ex e] [Ex d] [Ex px]
Screw thread (Connection data 1)M3
ATEX (Insulation characteristics) II (2) G [Ex e] [Ex d] [Ex px]
Category code (Connection data 2)NLDX / NRNT
Degree of protection (Dimensions)IP20
Mounting type (Overspeed tripping)DIN rail mounting
Rated insulation voltage (UL data)550 V
Type of protection (Device supply)Reverse polarity protection
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Connection name (Connection data 1)Load circuit
Operating mode (Overspeed tripping)100% operating factor
REACh SVHC (Approvals/conformities)Lead 7439-92-1
Status display (Overspeed tripping)Yellow LED
Switching threshold (Device supply)9.6 V (“0” signal)
Operating voltage range (Input data)42 V AC ... 550 V AC
Stripping length (Connection data 1)8 mm
Weight per Piece (excluding packing)282.700 g
Conductor cross section AWG (General)24 ... 14
Connection method (Connection data 1)Screw connection
Typical turn-off time (Device supply)< 30 ms
Group installation (Connection data 2)20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Rated operating current Ie (Input data)0.6 A (AC-51)
Rated operating voltage Ue (Input data)500 V AC
Response time (Output data load output)< 0.5 s
Type of protection (Ambient conditions)Surge protection
Designation (Insulation characteristics)Standards/regulations
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Triggering voltage range (Device supply)19.2 V DC ... 30 V DC
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated actuating current IC (Device supply)7 mA
Rated actuating voltage UC (Device supply)24 V DC
UL certificate (Standards and Regulations)NLDX.E228652
Operate threshold (Output data load output)> 10 A
Ambient temperature (operation) (Dimensions)-5 °C ... 60 °C (observe derating)
Maximum power dissipation (Overspeed tripping)2.5 W
Minimum power dissipation (Overspeed tripping)0.88 W
Operating voltage display (Overspeed tripping)Green LED
Conductor cross section AWG (Connection data 1)24 ... 14
Conductor cross section solid (Connection data 1)0.2 mm² ... 2.5 mm²
Control supply voltage range (Ambient conditions)19.2 V DC ... 30 V DC
Standards/regulations (Insulation characteristics)IEC 60947-1
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Connection data 1)0.2 mm² ... 2.5 mm²
Rated control supply current IS (Ambient conditions)60 mA
Category acc. to EN ISO 13849 (Standards and Regulations)≤ 3 (Safe shutdown)
EU-type examination certificate (Standards and Regulations)PTB 15 ATEX 3000
Rated control circuit supply voltage US (Ambient conditions)24 V DC
Trigger characteristic in acc. with IEC 60947-4-2 (Input data)Class 10
Performance level according to ISO 13849 (Standards and Regulations)e (Safe shutdown)
Safety Integrity Level according to IEC 61508 (Standards and Regulations)≤ 3 (Safe shutdown)

Product Description

Networkable hybrid start controller for starting 3~ AC motors up to 500 V AC, output current: 0.6 A, emergency stop function, adjustable overload disconnect and screw connection, bus connector for att
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top