Service time: Monday to Friday 9:00-18:00
ELR H3-IES-SC-230AC/500AC-2 - ELR H3-IES-SC-230AC/500AC-2 2900568 PHOENIX CONTACT 3 in 1 hybrid motor starter for starting 3~ AC motors up..
In Stock Hot Product

ELR H3-IES-SC-230AC/500AC-2

ELR H3-IES-SC-230AC/500AC-2 2900568 PHOENIX CONTACT 3 in 1 hybrid motor starter for starting 3~ AC motors up..

$0.00USD
3486 in stock
Key Specifications
Depth:114.5 mm
Width:22.5 mm
Height:99 mm
(UL data): II (2) D [Ex t] [Ex p]
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Depth114.5 mm
Width22.5 mm
Height99 mm
(UL data) II (2) D [Ex t] [Ex p]
(Input data)60 Hz
ATEX (UL data) II (2) G [Ex e] [Ex d] [Ex px]
(Device supply)85 V AC (“1” signal)
Torque (General)0.5 Nm ... 0.6 Nm
UNSPSC 11 (ETIM)39121514
ETIM 2.0 (eCl@ss)EC000066
ETIM 3.0 (eCl@ss)EC000066
ETIM 4.0 (eCl@ss)EC000066
ETIM 5.0 (eCl@ss)EC002055
UNSPSC 13.2 (ETIM)39121514
UNSPSC 6.01 (ETIM)30211915
UNSPSC 12.01 (ETIM)39121514
UNSPSC 7.0901 (ETIM)39121514
Designation (UL data)Standards/regulations
Screw thread (General)M3
(Standards/regulations)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Output name (Input data)AC output
(Approvals/conformities)30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Connection name (General)Control circuits
Cooling time (Input data)20 min. (for auto reset)
(Output data load output)2 A (24 V, DC13)
Input name (Device supply)Control input right/left
Stripping length (General)8 mm
Connection method (General)Screw connection
FLA (Approvals/conformities)2.4 A (480 V AC)
Leakage current (Input data)0 mA
Mains frequency (Input data)50 Hz
(Insulation characteristics) II (2) D [Ex t] [Ex p]
SCCR (Approvals/conformities)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Voltage range (Device supply)85 V AC ... 253 V AC
Note (Output data load output)Confirmation: floating change-over contact, signal contact
(Connection data, output side)ISO 13849
Load current range (Input data)180 mA ... 2.4 A (see to derating)
Protective circuit (Input data)Surge protection
Standards/regulations (UL data)IEC 60947-1
Switching level (Device supply)< 5 V AC (For EMERGENCY STOP)
ATEX (Insulation characteristics) II (2) G [Ex e] [Ex d] [Ex px]
Degree of protection (Dimensions)IP20
Insulation (Standards/regulations)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Designation (Standards/regulations)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Switching threshold (Device supply)44 V AC (“0” signal)
Operating voltage range (Input data)42 V AC ... 550 V AC
Torque (Connection data, input side)0.5 Nm ... 0.6 Nm
Conductor cross section AWG (General)24 ... 14
Indication (Output data reply output)Red LED
Output name (Output data load output)Acknowledge output
Typical turn-off time (Device supply)< 70 ms
Category code (Approvals/conformities)NLDX / NRNT
Contact type (Output data load output)1 PDT
eCl@ss 4.0 (Standards and Regulations)27371102
eCl@ss 4.1 (Standards and Regulations)27371102
eCl@ss 5.0 (Standards and Regulations)27371601
eCl@ss 5.1 (Standards and Regulations)27371601
eCl@ss 6.0 (Standards and Regulations)27371601
eCl@ss 7.0 (Standards and Regulations)27371601
eCl@ss 8.0 (Standards and Regulations)27370905
eCl@ss 9.0 (Standards and Regulations)27370905
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Protective circuit (Ambient conditions)Surge protection
Rated operating voltage Ue (Input data)500 V AC
Operating mode (Output data reply output)100% operating factor
Status display (Output data reply output)Yellow LED
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Designation (Connection data, output side)Standards/regulations
Rated actuating current IC (Device supply)7 mA
Rated actuating voltage UC (Device supply)230 V AC
Screw thread (Connection data, input side)M3
Degree of pollution (Standards/regulations)2
Group installation (Approvals/conformities)20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Rated surge voltage (Standards/regulations)4 kV
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (observe derating)
Mounting position (Output data reply output)vertical (horizontal DIN rail, motor output below)
Overvoltage category (Standards/regulations)III
Connection name (Connection data, input side)Load circuit
Rated operating current at AC-51 (Input data)2.4 A
Rated operating current at AC-53a (Input data)2.4 A
Stripping length (Connection data, input side)8 mm
Switching frequency (Output data reply output)≤ 2 Hz (Load-dependent)
Connection method (Connection data, input side)Screw connection
Assembly instructions (Output data reply output)alignable, for spacing see derating
Rated insulation voltage (Standards/regulations)500 V
Control supply voltage range (Ambient conditions)85 V AC ... 253 V AC
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Maximum power dissipation (Output data reply output)4.1 W
Minimum power dissipation (Output data reply output)0.88 W
Operating voltage display (Output data reply output)Green LED
Rated control supply current IS (Ambient conditions)4 mA
Standards/regulations (Connection data, output side)IEC 60947-1
Conductor cross section AWG (Connection data, input side)24 ... 14
Category acc. to EN ISO 13849 (Insulation characteristics)3 (Safe shutdown)
Trigger characteristic in acc. with IEC 60947 (Input data)Class 10A
Conductor cross section solid (Connection data, input side)0.2 mm² ... 2.5 mm²
EU-type examination certificate (Insulation characteristics)PTB 07 ATEX 3145
Rated control circuit supply voltage US (Ambient conditions)230 V AC (50/60 Hz)
Conductor cross section flexible (Connection data, input side)0.2 mm² ... 2.5 mm²
Performance level according to ISO 13849 (Insulation characteristics)e (Safe shutdown)
Switching capacity according to IEC 60947-5-1 (Output data load output)3 A (230 V, AC15)
Safety Integrity Level according to IEC 61508 (Insulation characteristics)SIL 3 (safe shutdown)

Product Description

Hybrid start controller for starting motors from 3~ AC up to 550 V AC, with 230 V AC input, 2.4 A output current, emergency stop function and adjustable overload disconnection.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top