Technical Specifications

ParameterValue
GTIN4046356920476
NoteMade to Order (non-returnable)
Orderkey2905142
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 26 (C-5-2017)
Packing unit1 pc
(Dimensions)1.5 hp (277 V AC / 480 V AC)
(Input data)3 A (AC-53a)
(Device supply)19.2 V (“1” signal)
FLA (Dimensions)3 A (480 V AC)
Country of originDE (Germany)
SCCR (Dimensions)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
(Key Commercial Data)Reverse polarity protection
Output name (Input data)AC output
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Cooling time (Input data)20 min. (for auto reset)
Category code (Dimensions)NLDX / NRNT
Depth (Ambient conditions)113.7 mm
Input name (Device supply)Enable input
Stripping length (General)10 mm
Width (Ambient conditions)22.5 mm
Connection method (General)Push-in connection
Height (Ambient conditions)107.4 mm
(Standards and Regulations)NRNT.E172140
Leakage current (Input data)0 mA
Mains frequency (Input data)50/60 Hz
(Insulation characteristics) II (2) D [Ex t] [Ex p]
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Overvoltage category (UL data)III
Group installation (Dimensions)20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Horsepower ratings (Dimensions)0.5 hp (120 V AC / 208 V AC)
Indication (Overspeed tripping)Red LED
Load current range (Input data)180 mA ... 3 A (see to derating)
Switching level (Device supply)< 5 V DC (For EMERGENCY STOP)
Type of protection (Input data)Surge protection
ATEX (Standards and Regulations) II (2) G [Ex e] [Ex d] [Ex px]
ATEX (Insulation characteristics) II (2) G [Ex e] [Ex d] [Ex px]
Mounting type (Overspeed tripping)DIN rail mounting
Rated insulation voltage (UL data)550 V
Type of protection (Device supply)Reverse polarity protection
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Operating mode (Overspeed tripping)100% operating factor
Status display (Overspeed tripping)Yellow LED
Switching threshold (Device supply)9.6 V (“0” signal)
Operating voltage range (Input data)42 V AC ... 550 V AC
Weight per Piece (excluding packing)282.700 g
Conductor cross section AWG (General)24 ... 14
Typical turn-off time (Device supply)< 30 ms
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Rated operating current Ie (Input data)3 A (AC-51)
Rated operating voltage Ue (Input data)500 V AC
Response time (Output data load output)< 0.5 s
Designation (Insulation characteristics)Standards/regulations
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Triggering voltage range (Device supply)19.2 V DC ... 30 V DC
Type of protection (Key Commercial Data)Surge protection
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated actuating current IC (Device supply)7 mA
Rated actuating voltage UC (Device supply)24 V DC
UL certificate (Standards and Regulations)NLDX.E228652
Operate threshold (Output data load output)> 33 A
Connection name (Connection data, input side)Load circuit
Maximum power dissipation (Overspeed tripping)4.1 W
Minimum power dissipation (Overspeed tripping)0.88 W
Operating voltage display (Overspeed tripping)Green LED
Stripping length (Connection data, input side)10 mm
Connection method (Connection data, input side)Push-in connection
Control supply voltage range (Key Commercial Data)19.2 V DC ... 30 V DC
Standards/regulations (Insulation characteristics)IEC 60947-1
Degree of protection (Connection data, output side)IP20
Rated control supply current IS (Key Commercial Data)60 mA
Category acc. to EN ISO 13849 (Standards and Regulations)≤ 3 (Safe shutdown)
Conductor cross section AWG (Connection data, input side)24 ... 14
Conductor cross section solid (Connection data, input side)0.2 mm² ... 2.5 mm²
EU-type examination certificate (Standards and Regulations)PTB 15 ATEX 3000
Rated control circuit supply voltage US (Key Commercial Data)24 V DC
Ambient temperature (operation) (Connection data, output side)-5 °C ... 60 °C (observe derating)
Conductor cross section flexible (Connection data, input side)0.2 mm² ... 2.5 mm²
Trigger characteristic in acc. with IEC 60947-4-2 (Input data)Class 10
Performance level according to ISO 13849 (Standards and Regulations)e (Safe shutdown)
Ambient temperature (storage/transport) (Connection data, output side)-40 °C ... 80 °C
Safety Integrity Level according to IEC 61508 (Standards and Regulations)≤ 3 (Safe shutdown)

Product Description

Networkable hybrid start controller for starting 3~ AC motors up to 500 V AC, output current: 3 A, emergency stop function, adjustable overload disconnect and push-in connection, bus connector for att
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top