Service time: Monday to Friday 9:00-18:00
ELR H3-IES-PT-24DC/500AC-2 - ELR H3-IES-PT- 24DC/500AC-2 2903916 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR H3-IES-PT-24DC/500AC-2

ELR H3-IES-PT- 24DC/500AC-2 2903916 PHOENIX CONTACT Hybrid motor starter

$0.00USD
3945 in stock
Key Specifications
:Reverse polarity protection
FLA:2.4 A (500 V AC)
Note:Confirmation: floating change-over contact, signal contact
SCCR:100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Reverse polarity protection
FLA2.4 A (500 V AC)
NoteConfirmation: floating change-over contact, signal contact
SCCR100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
Depth114 mm
Width22.5 mm
Height107.5 mm
Altitude≤ 2000 m
Input nameControl input
CertificateUKCA-compliant
Cooling time20 min. (for auto reset)
Product typeHybrid motor starters
Assembly notealignable, for spacing see derating
Category codeNLDX
Mounting typeDIN rail mounting
Identification II (2) G [Ex e] [Ex d] [Ex px]
Operating mode100% operating factor
Product familyCONTACTRON
Status displayLED (yellow)
Leakage current0 mA
Mains frequency50/60 Hz
Switching level< 5 V DC (For EMERGENCY STOP)
Article revision05
Error indicationRed LED
Number of phases3
Stripping length10 mm
Connection methodPush-in connection
Coordination type1
Mounting positionvertical (horizontal DIN rail, motor output below)
Group installation20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Load current range180 mA ... 2.4 A (see to derating)
Motor starter typeDirect starter
Notes on operationIf this device is to be used in combination with the CrossPowerSystem power distribution board, the device mount for the 16 A fuse (order designation: EM-CPS-DA-22,5F/16A; order number: 1002668) is required in order to attach the hybrid motor starter to the power distribution board.
Protective circuitSurge protection
Degree of pollution2
Rated surge voltage6 kV
Switching frequency≤ 2 Hz (Load-dependent)
Switching threshold9.6 V (“0” signal)
Degree of protectionIP20
Overvoltage categoryIII
Standards/regulationsIEC 60947-1
Typical turn-off time< 30 ms
Contact switching type1 changeover contact
Operating voltage range42 V AC ... 550 V AC
Rated insulation voltage500 V
Triggering voltage range19.2 V DC ... 30 V DC
Maximum power dissipation3.3 W
Minimum power dissipation1.1 W
Operating voltage displayGreen LED
Rated actuating current IC5 mA (Input type 1)
Rated actuating voltage UC24 V DC
Rated operating current Ie2.4 A (AC-51)
Rated operating voltage Ue500 V AC
Conductor cross section AWG24 ... 14
Control supply voltage range19.2 V DC ... 30 V DC
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Ambient temperature (operation)-25 °C ... 70 °C (observe derating)
Rated control supply current IS40 mA
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Flammability rating according to UL 94V0 (Housing)
Ambient temperature (storage/transport)-40 °C ... 80 °C
Rated control circuit supply voltage US24 V DC
Maximum power dissipation for nominal condition2.2 W
Trigger characteristic in acc. with IEC 60947-4-2Class 10A
Switching capacity in accordance with IEC 60947-5-13 A (230 V, AC15)
Isolation characteristics between the control input and control supply voltage to auxiliary circuitSafe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
Insulation characteristics between the control input and control supply voltage, and auxiliary circuit to the main circuitSafe isolation (IEC 60947-1) at operating voltage ≤ 300 V AC

Product Description

Hybrid start controller for starting 3~ AC motors up to 500 V AC and 2.4 A output current, with 24 V DC control voltage, adjustable overload disconnect, emergency stop function up to SIL 3/PL e and pu
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top