Service time: Monday to Friday 9:00-18:00
ELR H3-I-SC/500AC-06-IFS - ELR H3-I-SC/500AC-06-IFS 2905162 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR H3-I-SC/500AC-06-IFS

ELR H3-I-SC/500AC-06-IFS 2905162 PHOENIX CONTACT Hybrid motor starter

$0.00USD
4405 in stock
Key Specifications
GTIN:4046356920292
Note:Made to Order (non-returnable)
Orderkey:2905162
(UL data):Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356920292
NoteMade to Order (non-returnable)
Orderkey2905162
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 27 (C-5-2017)
Packing unit1 pc
(Device supply)0.6 A (AC-53a)
Torque (General)0.5 Nm ... 0.6 Nm (5-7 lbs-in)
Country of originDE (Germany)
(Connection data 2)30 A (class CC or J, SCCR 100kA (480 V AC), #24 - 14 AWG max, solid and stranded)
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
(Ambient conditions)Reverse polarity protection
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
Screw thread (General)M3
FLA (Connection data 2)0.6 A (480 V AC)
SCCR (Connection data 2)100 kA (480 V AC (fuse: 30 A class CC/30 A class J (high fault)))
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Stripping length (General)8 mm
Torque (Connection data 1)0.5 Nm ... 0.6 Nm (5-7 lbs-in)
Connection method (General)Screw connection
Depth (Key Commercial Data)113.7 mm
Output name (Device supply)AC output
Width (Key Commercial Data)22.5 mm
(Standards and Regulations)NRNT.E172140
Cooling time (Device supply)20 min. (for auto reset)
Height (Key Commercial Data)106.6 mm
(Insulation characteristics)EN 60947-4-2
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Overvoltage category (UL data)III
Indication (Overspeed tripping)Red LED
Leakage current (Device supply)0 mA
Mains frequency (Device supply)50/60 Hz
Screw thread (Connection data 1)M3
Category code (Connection data 2)NLDX / NRNT
Degree of protection (Dimensions)IP20
Load current range (Device supply)75 mA ... 600 mA (see to derating)
Mounting type (Overspeed tripping)DIN rail mounting
Rated insulation voltage (UL data)550 V
Type of protection (Device supply)Surge protection
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Connection name (Connection data 1)Load circuit
Operating mode (Overspeed tripping)100% operating factor
Status display (Overspeed tripping)Yellow LED
Stripping length (Connection data 1)8 mm
Weight per Piece (excluding packing)282.700 g
Conductor cross section AWG (General)24 ... 14
Connection method (Connection data 1)Screw connection
Group installation (Connection data 2)20 A (class RK5, SCCR 5kA (480 V AC), #24 - 14 AWG max. solid and stranded)
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Operating voltage range (Device supply)42 V AC ... 550 V AC
Response time (Output data load output)< 0.5 s
Type of protection (Ambient conditions)Surge protection
Designation (Insulation characteristics)Standards/regulations
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated operating current Ie (Device supply)0.6 A (AC-51)
Rated operating voltage Ue (Device supply)500 V AC
UL certificate (Standards and Regulations)NLDX.E228652
Operate threshold (Output data load output)> 10 A
Ambient temperature (operation) (Dimensions)-5 °C ... 60 °C (observe derating)
Maximum power dissipation (Overspeed tripping)2.5 W
Minimum power dissipation (Overspeed tripping)0.88 W
Operating voltage display (Overspeed tripping)Green LED
Conductor cross section AWG (Connection data 1)24 ... 14
Conductor cross section solid (Connection data 1)0.2 mm² ... 2.5 mm²
Control supply voltage range (Ambient conditions)19.2 V DC ... 30 V DC
Standards/regulations (Insulation characteristics)IEC 60947-1
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Connection data 1)0.2 mm² ... 2.5 mm²
Rated control supply current IS (Ambient conditions)60 mA
Rated control circuit supply voltage US (Ambient conditions)24 V DC
Trigger characteristic in acc. with IEC 60947-4-2 (Device supply)Class 10

Product Description

Networkable hybrid start controller for starting 3~ AC motors up to 500 V AC, output current: 0.6 A, adjustable overload disconnect and screw connection, bus connector for attached rail.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top