Service time: Monday to Friday 9:00-18:00
ELR H3-I-PT-24DC/500AC-9 - ELR H3-I-PT- 24DC/500AC-9 2903924 PHOENIX CONTACT Hybrid motor starter
In Stock Hot Product

ELR H3-I-PT-24DC/500AC-9

ELR H3-I-PT- 24DC/500AC-9 2903924 PHOENIX CONTACT Hybrid motor starter

$0.00USD
3740 in stock
Key Specifications
GTIN:4046356771672
Orderkey:2903924
(UL data):Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog page:Page 31 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356771672
Orderkey2903924
(UL data)Safe isolation (EN 50178) in the auxiliary circuit ≤ 300 V AC
Catalog pagePage 31 (C-5-2017)
Packing unit1 pc
(Input data)6.5 A (AC-53a)
(Device supply)19.2 V (“1” signal)
Country of originDE (Germany)
(Connection data 2)30 A (class CC or J, SCCR 100kA, #24 - 14 AWG max, solid and stranded)
Custom tariff number85371098
Insulation (UL data)Safe isolation (IEC 60947-1) in the auxiliary circuit ≤ 300 V AC
(Ambient conditions)Reverse polarity protection
Designation (UL data)Isolation characteristics between the control input and control supply voltage to auxiliary circuit
FLA (Connection data 2)6.5 A (500 V AC)
Output name (Input data)AC output
SCCR (Connection data 2)100 kA (500 V AC (fuse: 30 A class CC/30 A class J (high fault)))
(Approvals/conformities)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Connection name (General)Control circuits
Cooling time (Input data)20 min. (for auto reset)
(Output data load output)2 A (24 V, DC13)
Input name (Device supply)Control input
Stripping length (General)10 mm
Connection method (General)Push-in connection
Depth (Key Commercial Data)113.7 mm
Width (Key Commercial Data)22.5 mm
Height (Key Commercial Data)107.4 mm
Leakage current (Input data)0 mA
(Insulation characteristics)ISO 13849
Degree of pollution (UL data)2
Rated surge voltage (UL data)6 kV
Note (Output data load output)Confirmation: floating change-over contact, signal contact
Overvoltage category (UL data)III
Indication (Overspeed tripping)Red LED
Load current range (Input data)1.5 A ... 9 A (see to derating)
Type of protection (Input data)Surge protection
Category code (Connection data 2)NLDX / NRNT
Degree of protection (Dimensions)IP20
Mounting type (Overspeed tripping)DIN rail mounting
Rated insulation voltage (UL data)500 V
Type of protection (Device supply)Reverse polarity protection
China RoHS (Approvals/conformities)Environmentally Friendly Use Period = 50
Connection name (Connection data 1)Load circuit
Operating mode (Overspeed tripping)100% operating factor
Status display (Overspeed tripping)Yellow LED
Switching threshold (Device supply)9.6 V (“0” signal)
Operating voltage range (Input data)42 V AC ... 550 V AC
Stripping length (Connection data 1)10 mm
Weight per Piece (excluding packing)217.700 g
Conductor cross section AWG (General)24 ... 14
Connection method (Connection data 1)Push-in connection
Output name (Output data load output)Acknowledge output
Typical turn-off time (Device supply)< 30 ms
Contact type (Output data load output)1 PDT
Group installation (Connection data 2)20 A (class RK5, SCCR 5kA, #24 - 14 AWG max. solid and stranded)
Mounting position (Overspeed tripping)vertical (horizontal DIN rail, motor output below)
Conductor cross section solid (General)0.2 mm² ... 2.5 mm²
Rated operating current Ie (Input data)9 A (AC-51)
Rated operating voltage Ue (Input data)500 V AC
Type of protection (Ambient conditions)Surge protection
Designation (Insulation characteristics)Standards/regulations
Response time (Output data reply output)2 s
Switching frequency (Overspeed tripping)≤ 2 Hz (Load-dependent)
Triggering voltage range (Device supply)19.2 V DC ... 30 V DC
Assembly instructions (Overspeed tripping)alignable, for spacing see derating
Conductor cross section flexible (General)0.2 mm² ... 2.5 mm²
Rated actuating current IC (Device supply)5 mA (Input type 1)
Rated actuating voltage UC (Device supply)24 V DC
UL certificate (Standards and Regulations)NLDX.E228652
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C (observe derating)
Operate threshold (Output data reply output)> 45 A
Maximum power dissipation (Overspeed tripping)14.6 W
Minimum power dissipation (Overspeed tripping)1.1 W
Operating voltage display (Overspeed tripping)Green LED
Conductor cross section AWG (Connection data 1)24 ... 14
Conductor cross section solid (Connection data 1)0.2 mm² ... 2.5 mm²
Control supply voltage range (Ambient conditions)19.2 V DC ... 30 V DC
Standards/regulations (Insulation characteristics)IEC 60947-1
Ambient temperature (storage/transport) (Dimensions)-40 °C ... 80 °C
Conductor cross section flexible (Connection data 1)0.2 mm² ... 2.5 mm²
Rated control supply current IS (Ambient conditions)40 mA
Rated control circuit supply voltage US (Ambient conditions)24 V DC
Trigger characteristic in acc. with IEC 60947-4-2 (Input data)Class 10A
Switching capacity according to IEC 60947-5-1 (Output data load output)3 A (230 V, AC15)

Product Description

Hybrid start controller for starting 3~ AC motors up to 500 V AC and 9 A output current, with 24 V DC control voltage, adjustable overload disconnect and push-in connection.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top