Service time: Monday to Friday 9:00-18:00
ELR H3-ES-SC-230AC/500AC-2 - ELR H3-ES-SC-230AC/500AC-2 2900553 PHOENIX CONTACT 2 in 1 hybrid motor starter for starting 3~ AC motors up ..
In Stock Hot Product

ELR H3-ES-SC-230AC/500AC-2

ELR H3-ES-SC-230AC/500AC-2 2900553 PHOENIX CONTACT 2 in 1 hybrid motor starter for starting 3~ AC motors up ..

$0.00USD
4230 in stock
Key Specifications
:85 V AC (signal "1")
FLA:2.4 A (480 V)
SCCR:100 kA (480 V AC (30 A Class DC / 30 A Class J (High-Fault)) fuse)
Depth:114 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
85 V AC (signal "1")
FLA2.4 A (480 V)
SCCR100 kA (480 V AC (30 A Class DC / 30 A Class J (High-Fault)) fuse)
Depth114 mm
Width22.5 mm
Height107 mm
Marked≤ 3
IsolationSafe separation
ObservationFeedback 01: Switching contact without potential
Rating Type1
Product TypeHybrid Motor Starter
Screw threadM3
Cool-down time20 min. (For automatic reset)
Operating ModeWorking time 100%
Product FamilyCONTACTRON
Connection typeScrew connection
Leakage Current0 mA
Mains Frequency50/60 Hz
Residual Stress< 0.3 V
Switching Level< 5 V AC (for emergency stop)
Error IndicationRed LED
Number of phases3
Protection IndexIP20
Status IndicationLED (yellow)
Protection CircuitProt. Surge
Drive voltage range92 V AC ... 253 V AC
Maximum dissipation4.7 W
Switching threshold44 V AC (signal "0")
Investment frequency≤ 2 Hz
AWG Conductor Section24 ... 14
Position for mountingVertical (horizontal rail)
Service voltage range42 V AC ... 550 V AC
Typical Shutdown Time< 70 ms
Charging Current Range180 mA ... 2.4 A (see derating)
Electrical service life3x 107operations
Rigid conductor section0.2 mm² ... 2.5 mm²
Minimal dissipated power2.6 W
Standards/SpecificationsDIN EN 50178
Installation instructionsAlignment with spacing = 20 mm
Length to be de-insulated8 mm
Operating voltage displayGreen LED
Sizing Insulation Voltage500 V
Flexible conductor section0.2 mm² ... 2.5 mm²
Sizing Service Current Iand2.4 A (AC-51)
Ambient Temperature (Service)-25°C ... 70 °C
U-dimensioning drive voltageC230 V AC
Dimensioning Transient Voltage6 kV
Assigned operating voltage Uand500 V AC
Sizing Control Power Current Is4 mA
Flammability class according to UL 94V0 (Housing)
Ambient Temperature (Storage/Transport)-40 °C ... 80 °C
Supply voltage range of the control system92 V AC ... 253 V AC
Assigned supply voltage of the control circuit Us230 V AC
Activation characteristic line according to IEC 60947-4-2Class 10A

Product Description

Hybrid start controller for starting motors from 3~ AC up to 550 V AC, with 230 V AC input, 2.4 A output current and emergency stop function.
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top