ELR 3-230AC/500AC- 2 - ELR 3-230AC/500AC- 2 2297206 PHOENIX CONTACT Solid-state contactor
In Stock Hot Product

ELR 3-230AC/500AC- 2

ELR 3-230AC/500AC- 2 2297206 PHOENIX CONTACT Solid-state contactor

$0.00USD
3988 in stock
Key Specifications
:60 Hz
FLA:2 A (at 500 V, AC Resistance)
SCCR:5 kA (20 A RK5 (standard fault) fuse)
Depth:114.5 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
60 Hz
FLA2 A (at 500 V, AC Resistance)
SCCR5 kA (20 A RK5 (standard fault) fuse)
Depth114.5 mm
Width40 mm
Height99 mm
Input nameControl input right/left
CertificateNMFT.E323771
Product typeSolid-state contactor
Screw threadM3
Assembly noteCan be aligned with spacing = 20 mm
Mounting typeDIN rail mounting
Surge current200 A (t = 10 ms)
Operating mode100% operating factor
Status displayLED (yellow)
Leakage current6 mA
Mains frequency50 Hz
Max. load value250 A2s
Article revision05
Error indicationRed LED
Number of phases3
Residual voltage< 1.5 V
Stripping length8 mm
Connection methodScrew connection
Mounting positionVertical (horizontal DIN rail)
Tightening torque0.5 Nm ... 0.6 Nm
Load current range100 mA ... 2 A (see to derating)
Protective circuitSurge protection; Varistor
Degree of pollution2
Rated surge voltage6 kV
Switching frequency≤ 1 Hz
Switching threshold48 V AC (“0” signal)
Degree of protectionIP20
Overvoltage categoryIII
Peak offstate voltage1200 V
Standards/regulationsDIN EN 50178
Operating voltage range48 V AC ... 575 V AC
Rated insulation voltage500 V
Surge voltage protection> 575 V AC
Triggering voltage range92 V AC ... 253 V AC
Rated actuating current IC12.5 mA
Rated actuating voltage UC230 V AC
Rated operating voltage Ue500 V AC
Conductor cross section AWG24 ... 14
Test voltage (Input/output)5 kVrms(50 Hz, 60 s)
Conductor cross section rigid0.2 mm² ... 2.5 mm²
Ambient temperature (operation)-25 °C ... 70 °C
Conductor cross section flexible0.2 mm² ... 2.5 mm²
Rated operating current at AC-512 A
Rated operating current at AC-53a2 A
Voltage range with reference to UC0.4 ... 1.1
Ambient temperature (storage/transport)-25 °C ... 70 °C
Insulation characteristics between the control input voltage to the main circuitBasic insulation

Product Description

Three-phase semiconductor contactor with 230 V AC input, 2 A output current, zero voltage switch, optionally with thermal fuse
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top