| Parameter | Value |
|---|---|
| GTIN | 4046356175609 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2297248 |
| (UL data) | EN 60947 |
| Catalog page | Page 43 (C-5-2017) |
| Packing unit | 1 pc |
| Depth (General) | 114.5 mm |
| Width (General) | 147.5 mm |
| Height (General) | 99 mm |
| Country of origin | DE (Germany) |
| Custom tariff number | 85364900 |
| (Ambient conditions) | 16 A (at 500 V, AC Resistance Air Heating) |
| Designation (UL data) | Standards/regulations |
| (Key Commercial Data) | 96 V AC (“1” signal) |
| FLA (Ambient conditions) | 16 A (at 500 V, AC Resistance) |
| Output name (Input data) | AC output |
| SCCR (Ambient conditions) | 5 kA (50 A RK5 (standard fault) fuse) |
| Surge current (Input data) | 300 A (t = 10 ms) |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Leakage current (Input data) | 6 mA |
| Residual voltage (Input data) | < 1.5 V |
| Load current range (Input data) | 100 mA ... 16 A (see to derating) |
| Standards/regulations (UL data) | DIN EN 50178 |
| Type of protection (Input data) | RCV circuit |
| Indication (Key Commercial Data) | Red LED |
| Input name (Key Commercial Data) | Control input right/left |
| Degree of protection (Dimensions) | IP20 |
| Operating voltage range (Input data) | 48 V AC ... 575 V AC |
| Status display (Key Commercial Data) | Yellow LED |
| Weight per Piece (excluding packing) | 1,781.300 g |
| Mains frequency (Key Commercial Data) | 50 Hz |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Screw thread (Output data load output) | M3 |
| Rated operating voltage Ue (Input data) | 500 V AC |
| Protective circuit (Key Commercial Data) | Surge protection Varistor |
| Connection name (Output data load output) | Control circuits |
| Switching threshold (Key Commercial Data) | 48 V AC (“0” signal) |
| Stripping length (Output data load output) | 8 mm |
| Connection method (Output data load output) | Screw connection |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 70 °C |
| Operating mode (Connection data load circuit) | 100% operating factor |
| Rated operating current at AC-51 (Input data) | 16 A |
| Rated operating current at AC-53a (Input data) | 12 A |
| Triggering voltage range (Key Commercial Data) | 92 V AC ... 253 V AC |
| Screw thread (Connection data, control circuit) | M4 |
| Mounting position (Connection data load circuit) | Vertical (horizontal DIN rail) |
| Rated actuating current IC (Key Commercial Data) | 12.5 mA |
| Rated actuating voltage UC (Key Commercial Data) | 230 V AC |
| Connection name (Connection data, control circuit) | Load circuit |
| Switching frequency (Connection data load circuit) | ≤ 1 Hz |
| Stripping length (Connection data, control circuit) | 8 mm |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Assembly instructions (Connection data load circuit) | Can be aligned with spacing = 40 mm |
| Connection method (Connection data, control circuit) | Screw connection |
| Conductor cross section AWG (Output data load output) | 24 ... 12 |
| Conductor cross section solid (Output data load output) | 0.2 mm² ... 4 mm² |
| Test voltage input/output (Connection data load circuit) | 5 kVrms |
| Voltage range with reference to UC (Key Commercial Data) | 0.4 ... 1.1 |
| Conductor cross section flexible (Output data load output) | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG (Connection data, control circuit) | 20 ... 6 |
| Conductor cross section solid (Connection data, control circuit) | 0.5 mm² ... 16 mm² |
| Conductor cross section flexible (Connection data, control circuit) | 0.5 mm² ... 16 mm² |
Technical specifications and performance data
Installation and operation guide