Service time: Monday to Friday 9:00-18:00
ELR 3-230AC/500AC-16 - ELR 3-230AC/500AC-16 2297248 PHOENIX CONTACT Solid-state contactor
In Stock Hot Product

ELR 3-230AC/500AC-16

ELR 3-230AC/500AC-16 2297248 PHOENIX CONTACT Solid-state contactor

$0.00USD
3062 in stock
Key Specifications
GTIN:4046356175609
Note:Made to Order (non-returnable)
Orderkey:2297248
(UL data):EN 60947
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356175609
NoteMade to Order (non-returnable)
Orderkey2297248
(UL data)EN 60947
Catalog pagePage 43 (C-5-2017)
Packing unit1 pc
Depth (General)114.5 mm
Width (General)147.5 mm
Height (General)99 mm
Country of originDE (Germany)
Custom tariff number85364900
(Ambient conditions)16 A (at 500 V, AC Resistance Air Heating)
Designation (UL data)Standards/regulations
(Key Commercial Data)96 V AC (“1” signal)
FLA (Ambient conditions)16 A (at 500 V, AC Resistance)
Output name (Input data)AC output
SCCR (Ambient conditions)5 kA (50 A RK5 (standard fault) fuse)
Surge current (Input data)300 A (t = 10 ms)
(Standards and Regulations)For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration”
Leakage current (Input data)6 mA
Residual voltage (Input data)< 1.5 V
Load current range (Input data)100 mA ... 16 A (see to derating)
Standards/regulations (UL data)DIN EN 50178
Type of protection (Input data)RCV circuit
Indication (Key Commercial Data)Red LED
Input name (Key Commercial Data)Control input right/left
Degree of protection (Dimensions)IP20
Operating voltage range (Input data)48 V AC ... 575 V AC
Status display (Key Commercial Data)Yellow LED
Weight per Piece (excluding packing)1,781.300 g
Mains frequency (Key Commercial Data)50 Hz
China RoHS (Standards and Regulations)Environmentally Friendly Use Period = 50
Screw thread (Output data load output)M3
Rated operating voltage Ue (Input data)500 V AC
Protective circuit (Key Commercial Data)Surge protection Varistor
Connection name (Output data load output)Control circuits
Switching threshold (Key Commercial Data)48 V AC (“0” signal)
Stripping length (Output data load output)8 mm
Connection method (Output data load output)Screw connection
Ambient temperature (operation) (Dimensions)-25 °C ... 70 °C
Operating mode (Connection data load circuit)100% operating factor
Rated operating current at AC-51 (Input data)16 A
Rated operating current at AC-53a (Input data)12 A
Triggering voltage range (Key Commercial Data)92 V AC ... 253 V AC
Screw thread (Connection data, control circuit)M4
Mounting position (Connection data load circuit)Vertical (horizontal DIN rail)
Rated actuating current IC (Key Commercial Data)12.5 mA
Rated actuating voltage UC (Key Commercial Data)230 V AC
Connection name (Connection data, control circuit)Load circuit
Switching frequency (Connection data load circuit)≤ 1 Hz
Stripping length (Connection data, control circuit)8 mm
Ambient temperature (storage/transport) (Dimensions)-25 °C ... 70 °C
Assembly instructions (Connection data load circuit)Can be aligned with spacing = 40 mm
Connection method (Connection data, control circuit)Screw connection
Conductor cross section AWG (Output data load output)24 ... 12
Conductor cross section solid (Output data load output)0.2 mm² ... 4 mm²
Test voltage input/output (Connection data load circuit)5 kVrms
Voltage range with reference to UC (Key Commercial Data)0.4 ... 1.1
Conductor cross section flexible (Output data load output)0.2 mm² ... 2.5 mm²
Conductor cross section AWG (Connection data, control circuit)20 ... 6
Conductor cross section solid (Connection data, control circuit)0.5 mm² ... 16 mm²
Conductor cross section flexible (Connection data, control circuit)0.5 mm² ... 16 mm²

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top