| Parameter | Value |
|---|---|
| () | 16 A (at 500 V, AC Resistance Air Heating) |
| GTIN | 4046356175630 |
| Note | Made to Order (non-returnable) |
| FLA () | 16 A (at 500 V, AC Resistance) |
| SCCR () | 5 kA (50 A RK5 (standard fault) fuse) |
| Orderkey | 2297277 |
| (UL data) | EN 60947 |
| Catalog page | Page 43 (C-5-2017) |
| Packing unit | 1 pc |
| Indication () | Red LED |
| Input name () | Control input right/left |
| Country of origin | DE (Germany) |
| Status display () | Yellow LED |
| Custom tariff number | 85364190 |
| Designation (UL data) | Standards/regulations |
| Protective circuit () | Reverse polarity protection Suppressor diode |
| Screw thread (General) | M4 |
| Switching threshold () | 9.6 V (“0” signal) |
| Output name (Input data) | AC output |
| Connection name (General) | Load circuit |
| Stripping length (General) | 8 mm |
| Surge current (Input data) | 1300 A (t = 10 ms) |
| Connection method (General) | Screw connection |
| Depth (Key Commercial Data) | 114.5 mm |
| Triggering voltage range () | 19.2 V DC ... 30 V DC |
| Width (Key Commercial Data) | 147.5 mm |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Height (Key Commercial Data) | 99 mm |
| Leakage current (Input data) | 6 mA |
| Rated actuating current IC () | 8.3 mA |
| Rated actuating voltage UC () | 24 V DC |
| Residual voltage (Input data) | < 1.5 V |
| Load current range (Input data) | 200 mA ... 37 A (see to derating) |
| Standards/regulations (UL data) | DIN EN 50178 |
| Type of protection (Input data) | RCV circuit |
| Operating voltage range (Input data) | 48 V AC ... 575 V AC |
| Weight per Piece (excluding packing) | 1,743.000 g |
| Conductor cross section AWG (General) | 20 ... 6 |
| Voltage range with reference to UC () | 0.8 ... 1.25 |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| REACh SVHC (Standards and Regulations) | Lead 7439-92-1 |
| Conductor cross section solid (General) | 0.5 mm² ... 16 mm² |
| Rated operating voltage Ue (Input data) | 500 V AC |
| Operating mode (Output data load output) | 100% operating factor |
| Conductor cross section flexible (General) | 0.5 mm² ... 16 mm² |
| Degree of protection (Key Commercial Data) | IP20 |
| Mounting position (Output data load output) | Vertical (horizontal DIN rail) |
| Rated operating current at AC-51 (Input data) | 37 A |
| Switching frequency (Output data load output) | ≤ 10 Hz |
| Rated operating current at AC-53a (Input data) | 25 A |
| Assembly instructions (Output data load output) | Can be aligned with spacing = 40 mm |
| Test voltage input/output (Output data load output) | 5 kVrms |
| Ambient temperature (operation) (Key Commercial Data) | -25 °C ... 70 °C |
| Ambient temperature (storage/transport) (Key Commercial Data) | -25 °C ... 70 °C |
Technical specifications and performance data