| Parameter | Value |
|---|---|
| GTIN | 4017918080242 |
| Note | Made to Order (non-returnable) |
| Orderkey | 2940799 |
| (General) | EN 61000-6-4 |
| Catalog page | Page 452 (C-5-2017) |
| Depth (Note) | 56 mm |
| Packing unit | 10 pc |
| Width (Note) | 6.2 mm |
| (Input data) | UVN- UR;in blocking state |
| Height (Note) | 80 mm |
| Country of origin | CN (China) |
| Custom tariff number | 85364190 |
| Torque (Output data) | 0.5 Nm |
| (Ambient conditions) | 0 mA ... 0.35 mA (In the event of a wire break) |
| Designation (General) | Air clearances and creepage distances |
| Designation (Input data) | Signal output |
| Screw thread (Output data) | M3 |
| (Standards and Regulations) | For details about hazardous substances go to tab “Downloads”, Category “Manufacturer's declaration” |
| Connection name (Output data) | Input side |
| Degree of pollution (General) | 2 |
| Overvoltage category (General) | III |
| Stripping length (Output data) | 8 mm |
| (Connection data, output side) | EN 61000-6-4 |
| Connection method (Output data) | Screw connection |
| Indication (Ambient conditions) | visual short-circuit and wire break control with LED (red) |
| Standards/regulations (General) | IEC 60664 |
| Type of protection (Input data) | 36 V Zener diode as free-wheeling diode |
| Designation (Ambient conditions) | Control circuit |
| Output nominal voltage (Input data) | ≤ 100 mV (In conductive state) |
| Switching point (Ambient conditions) | ≥ 2.1 mA (In conductive state) |
| Torque (Connection data, input side) | 0.5 Nm |
| Weight per Piece (excluding packing) | 21.100 g |
| China RoHS (Standards and Regulations) | Environmentally Friendly Use Period = 50 |
| Type of protection (Ambient conditions) | 12 V Zener diode |
| Input voltage range (Ambient conditions) | 18.5 V DC ... 28.8 V DC (UVN, see derating curve) |
| Internal resistance (Ambient conditions) | approx. 1 kΩ |
| Limiting continuous current (Input data) | 50 mA |
| Conductor cross section AWG (Output data) | 24 ... 12 |
| Protective circuit/component (Input data) | 36 V Zener diode as free-wheeling diode |
| Switching hysteresis (Ambient conditions) | approx. 0.2 mA |
| Designation (Connection data, output side) | Air clearances and creepage distances |
| Screw thread (Connection data, input side) | M3 |
| Conductor cross section solid (Output data) | 0.2 mm² ... 4 mm² |
| Transmission frequency (Ambient conditions) | 1 kHz |
| Type of note (Connection data, output side) | Note on application |
| Ambient temperature (operation) (Dimensions) | -25 °C ... 50 °C |
| Connection name (Connection data, input side) | Output side |
| Max. current consumption (Ambient conditions) | 70 mA (at 50 mA output current) |
| Nominal input voltage UN (Ambient conditions) | 8.2 V DC ±10 % |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Conductor cross section flexible (Output data) | 0.2 mm² ... 2.5 mm² |
| Operating voltage display (Ambient conditions) | Green LED |
| Stripping length (Connection data, input side) | 8 mm |
| Connection method (Connection data, input side) | Screw connection |
| Mounting position (Connection data, output side) | any |
| Typical input current at UN (Ambient conditions) | 70 mA |
| Protective circuit/component (Ambient conditions) | 12 V Zener diode |
| Degree of pollution (Connection data, output side) | 2 |
| Overvoltage category (Connection data, output side) | III |
| Ambient temperature (storage/transport) (Dimensions) | -25 °C ... 70 °C |
| Assembly instructions (Connection data, output side) | In rows with zero spacing |
| Standards/regulations (Connection data, output side) | IEC 60664 |
| Conductor cross section AWG (Connection data, input side) | 24 ... 12 |
| Conductor cross section solid (Connection data, input side) | 0.2 mm² ... 4 mm² |
| Voltage drop at max. limiting continuous current (Input data) | ≤ 1.5 V (UR) |
| Conductor cross section flexible (Connection data, input side) | 0.2 mm² ... 2.5 mm² |
Technical specifications and performance data