Service time: Monday to Friday 9:00-18:00
EEM-MA600 - EEM-MA600 2901366 PHOENIX CONTACT Measuring instrument
In Stock Hot Product

EEM-MA600

EEM-MA600 2901366 PHOENIX CONTACT Measuring instrument

$0.00USD
3532 in stock
Key Specifications
GTIN:4046356584258
Orderkey:2901366
(UL data):cULus
Catalog page:Page 208 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356584258
Orderkey2901366
(UL data)cULus
Catalog pagePage 208 (C-5-2017)
Depth (Note)82 mm
Packing unit1 pc
Width (Note)96 mm
Height (Note)96 mm
Note (General)Current connection
Country of originTN (Tunisia)
(Connection data)50 % (at 40 °C)
Color (Interfaces)black
Custom tariff number90303100
Display (Interfaces)LCD display, backlighting
(Ambient conditions)0 MVA ... 8000 MVA
Conformance (UL data)CE-compliant
Mains type (Interfaces)3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire)
Conformance (Interfaces)CE-compliant
UL, USA/Canada (UL data)UL 61010-1
Designation (Output data)via communication module
Test voltage (Interfaces)3.5 kV AC (50 Hz, 1 min.)
Altitude (Connection data)≤ 2000 m
Stripping length (General)7 mm
Connection method (General)Screw connection
Measuring rate (Interfaces)approximately
Supply voltage (Interfaces)230 V AC
Tightening torque (General)0.4 Nm
(Standards and Regulations)No hazardous substances above threshold values
Power consumption (Interfaces)20 VA (with max. number of extension modules)
Precision (Ambient conditions)0.5 %
Input name (Ambient conditions)Current measurement I1, I2, I3
Output description (Input data)Via function module
Operating mode (Connection data)Indoor use
Surge voltages (Connection data)Transient overvoltage according to installation classes
Supply voltage range (Interfaces)110 V AC ... 400 V AC ±10 %
Input current (Ambient conditions)9999 A (primary)
Input voltage (Ambient conditions)500 kV AC (Primary, via external voltage transducers)
Measured value (Ambient conditions)AC sine (50/60 Hz)
Power consumption (Connection data)10 VA
Max. salt spray content (Dimensions)≤ 2.5 %
Weight per Piece (excluding packing)821.500 g
Current overload (Ambient conditions)10 x INfor 1 s
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Nominal power consumption (Interfaces)10 VA
Overload capacity (Ambient conditions)6 A (Permanent)
Overvoltage category (Connection data)I, II, III
Input current range (Ambient conditions)via external transformers
Input voltage range (Ambient conditions)18 V AC ... 700 V AC (Phase/Phase)
Measuring principle (Ambient conditions)True r.m.s. value measurement
Messbereich_Leistung (Ambient conditions)0 MW ... 8000 MW
Voltage input signal (Ambient conditions)Via function module
Conductor cross section AWG max. (General)8
Conductor cross section AWG min. (General)20
Ambient temperature (operation) (Dimensions)-10 °C ... 55 °C (14 °F to 131 °F)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)0.5 mm²
Current measuring range (Ambient conditions)0 A ... 9999 A
Acquisition of harmonics (Ambient conditions)up to 63rd harmonic
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Nominal supply voltage range (Connection data)110 V AC ... 240 V AC ±10 %
Conductor cross section flexible max. (General)6 mm²
Conductor cross section flexible min. (General)0.5 mm²
Installation depth with extension module (Note)80 mm
Active energy (IEC 62053-22) (Ambient conditions)Class 0.5 S
Ambient temperature (operation) (Connection data)0 °C ... 40 °C
Installation depth without extension module (Note)60 mm
Reactive power (IEC 62053-23) (Ambient conditions)Class 2
Ambient temperature (storage/transport) (Dimensions)-20 °C ... 85 °C (-4 °F ... 185 °F)
Overvoltage category of the supply (Connection data)Min. II
Max. permissible relative humidity (operation) (Dimensions)≤ 95 %
Max. permissible relative humidity (operation) (Connection data)80 % (up to 31°C)
Rated insulation voltage at mains voltage < 300 V AC (L/N) (Interfaces)III
Response threshold from measuring range nominal value (Ambient conditions)10 mA
Rated insulation voltage at mains voltage > 300 V AC - 600 V AC (L/N) (Interfaces)II

Product Description

More details
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top