Service time: Monday to Friday 9:00-18:00
EEM-MA400 - EEM-MA400 2901364 PHOENIX CONTACT Measuring instrument
In Stock Hot Product

EEM-MA400

EEM-MA400 2901364 PHOENIX CONTACT Measuring instrument

$0.00USD
3684 in stock
Key Specifications
GTIN:4046356585804
Orderkey:2901364
(UL data):cULus
Catalog page:Page 209 (C-5-2017)
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
GTIN4046356585804
Orderkey2901364
(UL data)cULus
Catalog pagePage 209 (C-5-2017)
Depth (Note)82 mm
Packing unit1 pc
Width (Note)96 mm
(Interfaces)2.2 kV AC (50 Hz, 1 min.)
Height (Note)96 mm
Note (General)Current connection
Country of originTN (Tunisia)
(Connection data)50 % (at 40 °C)
Color (Interfaces)black
Custom tariff number90303100
Display (Interfaces)LCD display, backlighting
(Ambient conditions)0 MVA ... 11 MVA
Conformance (UL data)CE-compliant
Mains type (Interfaces)3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire)
Conformance (Interfaces)CE-compliant
UL, USA/Canada (UL data)UL 61010-1
Designation (Output data)via communication module
Test voltage (Interfaces)3.5 kV AC (50 Hz, 1 min.)
Altitude (Connection data)≤ 2000 m
Stripping length (General)7 mm
Connection method (General)Screw connection
Measuring rate (Interfaces)approximately
Tightening torque (General)0.4 Nm
(Standards and Regulations)No hazardous substances above threshold values
Power consumption (Interfaces)10 VA (with max. number of extension modules)
Precision (Ambient conditions)0.5 %
Input name (Ambient conditions)Voltage measuring input V1, V2, V3
Output description (Input data)Via function module
Operating mode (Connection data)Indoor use
Supply voltage (Connection data)300 V AC
Surge voltages (Connection data)Transient overvoltage according to installation classes
Overvoltage category (Interfaces)III
Supply voltage range (Interfaces)110 V AC ... 400 V AC ±10 %
Input current (Ambient conditions)9999 A (primary)
Measured value (Ambient conditions)AC sine (50/60 Hz)
Power consumption (Connection data)10 VA
Max. salt spray content (Dimensions)≤ 2.5 %
Weight per Piece (excluding packing)704.200 g
Current overload (Ambient conditions)10 x INfor 1 s
Rated insulation voltage (Interfaces)300 V AC (EN 61010-1)
China RoHS (Standards and Regulations)Environmentally friendly use period: unlimited = EFUP-e
Nominal power consumption (Interfaces)5 VA
Overload capacity (Ambient conditions)6 A (Permanent)
Overvoltage category (Connection data)I, II, III
Input current range (Ambient conditions)via external transformers
Input voltage range (Ambient conditions)50 V AC ... 500 V AC (Phase/Phase)
Measuring principle (Ambient conditions)True r.m.s. value measurement
Messbereich_Leistung (Ambient conditions)0 MW ... 11 MW
Conductor cross section AWG max. (General)8
Conductor cross section AWG min. (General)20
Ambient temperature (operation) (Dimensions)-10 °C ... 55 °C (14 °F to 131 °F)
Conductor cross section solid max. (General)6 mm²
Conductor cross section solid min. (General)0.5 mm²
Current measuring range (Ambient conditions)0 A ... 9999 A
Acquisition of harmonics (Ambient conditions)up to 51st harmonic
Utilization restriction (Key Commercial Data)EMC: class A product, see manufacturer's declaration in the download area
Nominal supply voltage range (Connection data)110 V AC ... 240 V AC ±10 %
Conductor cross section flexible max. (General)6 mm²
Conductor cross section flexible min. (General)0.5 mm²
Installation depth with extension module (Note)80 mm
Active energy (IEC 62053-22) (Ambient conditions)Class 0.5 S
Ambient temperature (operation) (Connection data)0 °C ... 40 °C
Installation depth without extension module (Note)60 mm
Reactive power (IEC 62053-23) (Ambient conditions)Class 2
Ambient temperature (storage/transport) (Dimensions)-20 °C ... 85 °C (-4 °F ... 185 °F)
Overvoltage category of the supply (Connection data)Min. II
Max. permissible relative humidity (operation) (Dimensions)≤ 95 %
Max. permissible relative humidity (operation) (Connection data)80 % (up to 31°C)
Response threshold from measuring range nominal value (Ambient conditions)5 mA

Product Description

Energy meter for measuring electrical parameters in low-voltage installations up to 500 V, recording of all harmonics - suitable for expansion with RS-485 communication module
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty

Product Documents

Datasheet

Technical specifications and performance data

User Manual

Installation and operation guide

Top