

| Parameter | Value |
|---|---|
| GTIN | 4046356585811 |
| Orderkey | 2901363 |
| (UL data) | cULus |
| Catalog page | Page 209 (C-5-2017) |
| Depth (Note) | 64 mm |
| Packing unit | 1 pc |
| Width (Note) | 72 mm |
| (Interfaces) | 2.2 kV AC (50 Hz, 1 min.) |
| Height (Note) | 90 mm |
| Note (General) | Current and voltage connection |
| Country of origin | FR (France) |
| (Connection data) | 50 % (at 40 °C) |
| Color (Interfaces) | black |
| Number (Input data) | 1 |
| Custom tariff number | 90303100 |
| Display (Interfaces) | LCD display, backlighting |
| (Ambient conditions) | 0 kVA ... 9999 kVA |
| Conformance (UL data) | CE-compliant |
| Interface (Output data) | RS-485 |
| Mains type (Interfaces) | 3-phase (3 or 4-wire), 2-phase (2-wire), and single-phase (1-wire) |
| Conformance (Interfaces) | CE-compliant |
| UL, USA/Canada (UL data) | UL 61010-1 |
| Designation (Output data) | Modbus RTU/JBUS |
| Test voltage (Interfaces) | 3.5 kV AC (50 Hz, 1 min.) |
| Altitude (Connection data) | ≤ 2000 m |
| Stripping length (General) | 6 mm |
| Connection method (General) | Screw connection |
| Measuring rate (Interfaces) | approximately |
| Number (Ambient conditions) | 1 |
| Tightening torque (General) | 0.6 Nm |
| (Standards and Regulations) | No hazardous substances above threshold values |
| Precision (Ambient conditions) | 0.5 % |
| Connection method (Output data) | Screw terminal blocks |
| Input name (Ambient conditions) | Voltage measuring input V1, V2, V3 |
| Output description (Input data) | Transistor output, active |
| Operating mode (Connection data) | Indoor use |
| Surge voltages (Connection data) | Transient overvoltage according to installation classes |
| Overvoltage category (Interfaces) | III |
| Supply voltage range (Interfaces) | 110 V AC ... 277 V AC -10 % ... +15 % |
| Input current (Ambient conditions) | 9999 A (primary) |
| Measured value (Ambient conditions) | AC sine (50/60 Hz) |
| Max. salt spray content (Dimensions) | ≤ 2.5 % |
| Weight per Piece (excluding packing) | 317.500 g |
| Rated insulation voltage (Interfaces) | 300 V AC (EN 61010-1) |
| China RoHS (Standards and Regulations) | Environmentally friendly use period: unlimited = EFUP-e |
| Current carrying capacity (Input data) | 27 mA |
| Maximum switching voltage (Input data) | 30 V DC |
| Nominal power consumption (Interfaces) | 5 VA |
| Overload capacity (Ambient conditions) | 6 A (Permanent) |
| Overvoltage category (Connection data) | I, II, III |
| Serial transmission speed (Output data) | 2,4 ... 38.4 kbps |
| Input current range (Ambient conditions) | via external transformers |
| Input voltage range (Ambient conditions) | 50 V AC ... 519 V AC (Phase/Phase) |
| Measuring principle (Ambient conditions) | True r.m.s. value measurement |
| Messbereich_Leistung (Ambient conditions) | 0 kW ... 9999 kW |
| Voltage input signal (Ambient conditions) | 230 V AC ±10 % (Tariff switchover: e.g., day/nighttime tariff) |
| Conductor cross section AWG max. (General) | 10 |
| Conductor cross section AWG min. (General) | 20 |
| Ambient temperature (operation) (Dimensions) | -10 °C ... 55 °C (14 °F to 131 °F) |
| Conductor cross section solid max. (General) | 4 mm² |
| Conductor cross section solid min. (General) | 0.5 mm² |
| Acquisition of harmonics (Ambient conditions) | up to 51st harmonic |
| Description of the input (Ambient conditions) | Digital input |
| Utilization restriction (Key Commercial Data) | EMC: class A product, see manufacturer's declaration in the download area |
| Nominal supply voltage range (Connection data) | 110 V AC ... 277 V AC -10 % ... +15 % |
| Conductor cross section flexible max. (General) | 4 mm² |
| Conductor cross section flexible min. (General) | 0.5 mm² |
| Active energy (IEC 62053-22) (Ambient conditions) | Class 0.5 S |
| Ambient temperature (operation) (Connection data) | 5 °C ... 40 °C |
| Reactive power (IEC 62053-23) (Ambient conditions) | Class 2 |
| Ambient temperature (storage/transport) (Dimensions) | -20 °C ... 70 °C (-4 °F ... 158 °F) |
| Overvoltage category of the supply (Connection data) | Min. II |
| Max. permissible relative humidity (operation) (Dimensions) | ≤ 95 % |
| Max. permissible relative humidity (operation) (Connection data) | 80 % (up to 31°C) |
| Response threshold from measuring range nominal value (Ambient conditions) | 5 mA |
Technical specifications and performance data
Installation and operation guide