Key Specifications
Type:non-vented
Depth:64 mm
Width:164 mm
Height:176 mm
Supplier Information
Products: 0
Usually ships within 2-3 business days
Quality Guaranteed
Fast Shipping
Technical Support

Technical Specifications

ParameterValue
Typenon-vented
Depth64 mm
Width164 mm
Height176 mm
ResultTest passed
Frequency10 - 2000 - 10 Hz
Pulse shapeSemi-sinusoidal
Sweep speed1 octave/min
Temperature850 °C
Acceleration15g (61.6 Hz ... 2000 Hz)
Housing typeOutdoor housing
Product typeHousing
Assembly noteRefer to the data sheet for the range in the download area.
Mounting typeWall or panel mount. Pole mount with accessory.
PCB thickness1.57 mm ... 2.36 mm
SpecificationIEC 60068-2-6:2007-12
Test duration96 h
Height of fall50 cm
Housing seriesECS
Product familyECS..122X..S..
Shock duration11 ms
Color (Housing)black (RAL 9005)
Impact strengthIK08
Test directionsX-, Y- and Z-axis
Article revision03
Housing materialPC (polycarbonate)
Time of exposure30 s
Dimensional drawing
Degree of protectionIP66/IP67
Thickness of the PCB1.57 mm ... 2.36 mm
Number of PCB holders1
Test duration per axis2.5 h
Surface characteristicsuntreated
Max. NEMA code to attain6
Number of shocks per direction3
Ambient temperature (operation)-40 °C ... 100 °C
Result, degree of protection, IP codeIP66/IP68 (2 m/24 h)
Flammability rating according to UL 94V0
Ambient temperature (storage/transport)-40 °C ... 100 °C

Product Description

Non-ventilated housing of the ECS family, screw lock. IP66/67/69 protection rating in case of combination with the corresponding faceplate. Colour: black (9005), width: 164 mm, height: 176 mm, depth:
Key Features
  • Industrial grade quality
  • RoHS compliant
  • CE certified
  • 1-year warranty