| Parameter | Value |
|---|---|
| Item (Specifications & ordering info) | Model |
| Type (Specifications & ordering info) | Size in mm (H×W×D) |
| Model (Specifications & ordering info) | Size (H×W×D) |
| E5L-A_ (Specifications & ordering info) | E5L-C_ |
| E5L-C_ (Specifications & ordering info) | 35 × 40 × 64 mm |
| Inputs (Specifications & ordering info) | Element-interchangeable thermistor |
| PTF14A (Specifications & ordering info) | 78.5×45.5×30.0 |
| PTF14A-E (Specifications & ordering info) | 78.5×45.5×33.0 |
| 0 to 50°C (Specifications & ordering info) | E5L-A-0-50 |
| Hysteresis (Specifications & ordering info) | −30 to 20°C models: Approx. 0.5 to 2.5°C (variable)0 to 50°C models: Approx. 0.5 to 4°C (variable)0 to 100°C models: Approx. 0.5 to 4°C (variable)100 to 200°C models: Approx. 0.7 to 4°C (variable) |
| 0 to 100°C (Specifications & ordering info) | E5L-C-0-100 |
| 100 to 200°C (Specifications & ordering info) | E5L-C-100-200 |
| Control method (Specifications & ordering info) | ON/OFF control |
| Control output (Specifications & ordering info) | SPDT contacts, 250 VAC, 10 A, cosδ= 1 (resistive load) |
| EMC Directives (Specifications & ordering info) | EMI: EN61326-1Radiated EMI: EN55011 Group 1 Class AConducted EMI: EN55011 Group 1 Class AEMS: EN61326-1Electrostatic discharge immunity: EN61000-4-2Electromagnetic field strength immunity: EN61000-4-3Burst noise immunity: EN61000-4-4Conducted disturbance immunity: EN61000-4-6Surge immunity: EN61000-4-5Voltage dip and power interruption immunity: EN61000-4-11 |
| Setting method (Specifications & ordering info) | Analog setting |
| Other functions (Specifications & ordering info) | − |
| Repeat accuracy (Specifications & ordering info) | 1% FS max |
| Sampling period (Specifications & ordering info) | − |
| Setting accuracy (Specifications & ordering info) | − |
| Indication method (Specifications & ordering info) | No display |
| Memory protection (Specifications & ordering info) | − |
| Power consumption (Specifications & ordering info) | Approx. 3 VA |
| Approved standards (Specifications & ordering info) | − |
| Conformed standards (Specifications & ordering info) | EN 61010-1 (IEC 61010-1), Pollution Degree 2, Overvoltage Category II |
| Dielectric strength (Specifications & ordering info) | 2,300 VAC, 50/60 Hz for 1 min (between charged terminals and uncharged metallic parts, between power supply terminals and input terminals, between power supply terminals and output terminals, and between input terminals and output terminals) |
| Indication accuracy (Specifications & ordering info) | − |
| Shock (destruction) (Specifications & ordering info) | 294 m/s2, 3 times each in 6 directions |
| Shock (malfunction) (Specifications & ordering info) | 147 m/s2, 3 times each in 6 directions |
| Weight (Thermostat) (Specifications & ordering info) | Approx. 80 g (Thermostat only) |
| Degree of protection (Specifications & ordering info) | Front panel: IP40, Terminals: IP00 |
| Influence of voltage (Specifications & ordering info) | − |
| Power supply voltage (Specifications & ordering info) | 100 to 240 VAC, 50/60 Hz |
| Insulation resistance (Specifications & ordering info) | 100 MΩmax. (at 500 VDC) |
| Front-connecting Socket (Specifications & ordering info) | PTF14A |
| Operating voltage range (Specifications & ordering info) | 85% to 110% of the rated supply voltage |
| Vibration (destruction) (Specifications & ordering info) | Frequency of 10 to 55 Hz, 0.75-mm double amplitude for 2 h each in X, Y, and Z directions |
| Vibration (malfunction) (Specifications & ordering info) | Frequency of 10 to 55 Hz, 0.5-mm double amplitude for 10 min each in X, Y, and Z directions |
| Influence of temperature (Specifications & ordering info) | − |
| Minimum scale (standard scale) (Specifications & ordering info) | −30 to 20°C models and 0 to 50°C models: 5°C0 to 100°C models and 100 to 200°C models: 10°C |
| Electrical life expectancy (control output relay) (Specifications & ordering info) | 100,000 operations min (at maximum applicable load) |
Technical specifications and performance data