| Parameter | Value |
|---|---|
| °C (ON/OFF control) | 0 to 200 (5),0 to 400 (10),0 to 600 (20),0 to 800 (20),0 to 1,000 (25),0 to 1,200 (25) |
| Input (ON/OFF control) | Control method |
| Output (ON/OFF control) | Relay, SPDT, 3 A at 250 VAC |
| Functions (ON/OFF control) | Order code |
| Hysteresis (ON/OFF control) | Approx. 0.5% FS (fixed) |
| Thermistor (ON/OFF control) | THE (replaceable element) |
| 0 to 50 °C (ON/OFF control) | E5C2-R20P-D AC100-240 0-50 |
| Reset range (ON/OFF control) | 5 ±1% FS min. |
| 0 to 100 °C (ON/OFF control) | E5C2-R20P-D AC100-240 0-100 |
| 0 to 200 °C (ON/OFF control) | E5C2-R20P-D AC100-240 0-200 |
| 0 to 300 °C (ON/OFF control) | E5C2-R20P-D AC100-240 0-300 |
| 0 to 400 °C (ON/OFF control) | E5C2-R20P-D AC100-240 0-400 |
| 0 to 600 °C (ON/OFF control) | E5C2-R20K AC100-240 0-600 |
| 0 to 800 °C (ON/OFF control) | E5C2-R20K AC100-240 0-800 |
| Control mode (ON/OFF control) | ON/OFF or P control |
| Input ranges (ON/OFF control) | Thermocouple1 |
| 0 to 1000 °C (ON/OFF control) | E5C2-R20K AC100-240 0-1000 |
| 0 to 1200 °C (ON/OFF control) | E5C2-R20K AC100-240 0-1200 |
| 100 to 200 °C (ON/OFF control) | E5C2-R20G AC100-240 100-200 |
| 150 to 300 °C (ON/OFF control) | E5C2-R20G AC100-240 150-300 |
| Control period (ON/OFF control) | 20 s |
| RTD input type (ON/OFF control) | Pt100, THE |
| Setting method (ON/OFF control) | analog setting |
| Supply voltage (ON/OFF control) | 100 to 240 VAC, 50/60 Hz |
| Life expectancy (ON/OFF control) | Electrical: 100,000 operations min. |
| Setting accuracy (ON/OFF control) | ±2% FS max. |
| Proportional band (ON/OFF control) | 3% FS (fixed) |
| Size in mm (HxWxD) (ON/OFF control) | 48×48×96 |
| Ambient temperature (ON/OFF control) | -10 to 55°C |
| IP rating terminals (ON/OFF control) | IP00 |
| IP Rating front panel (ON/OFF control) | IP40 (IP66 cover available) |
| Resistance thermometer (ON/OFF control) | Platinum resistance thermometer |
| Thermocouple input type (ON/OFF control) | K, J (with sensor break detection) |
| Output/Indication method (ON/OFF control) | Relay/No indication |
| K (CA) chromel vs. alumel (ON/OFF control) | J (IC) iron vs. constantan |
| Input/ standard scale (°C) (ON/OFF control) | Thermocouple |
| J (IC) Iron versus Constantan (ON/OFF control) | 0 to 200 °C |
| Protective front cover (IP66) (ON/OFF control) | Y92A-48B |
| Finger protection cover (for P3G-08) (ON/OFF control) | Y92A-48G |
| Back connecting socket (for flush mounting) (ON/OFF control) | P3G-08 |
| Front connecting socket with finger protection (ON/OFF control) | P2CF-08-E |
No description available for this product.
Technical specifications and performance data
Installation and operation guide